Thermal models for overhead contact lines and their validation

被引:0
作者
Golle, Ingo [1 ]
Holderegger, Martin [1 ]
Steinegger, Urs [2 ]
机构
[1] SBB AG, Infrastruktur Elektrotechnik, Industriestr. 1, Zollikofen,3052, Switzerland
[2] Meteodat GmbH, Technoparkstr. 1, Zurich,8005, Switzerland
来源
eb - Elektrische Bahnen | 2015年 / 113卷 / 10期
关键词
Overhead lines;
D O I
暂无
中图分类号
学科分类号
摘要
The heating of the components of overhead contact lines depends not only on the flowing currents but also on the ambient meteorological conditions. Solar heating, velocity and direction of the wind and air temperature form essential effects. Swiss Railways SBB developed models for calculating the thermal behavior of contact lines which adequately consider these factors. The models were validated by measurements at overhead contact lines in operation. It is planned to utilize the results for parameterizing the thermal contact line protection equipment.
引用
收藏
页码:498 / 511
相关论文
共 50 条
[41]   Conductor rail overhead contact line on the folding bridge in Anklam [J].
Schatkowski, Kay ;
Furrer, Rico ;
Wili, Urs .
eb - Elektrische Bahnen, 2015, 113 (6-7) :342-346
[42]   An alternative procedure for the design of high voltage overhead transmission lines [J].
Saied, MM .
1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, :708-714
[43]   Alternative to Monte Carlo method for the estimation of lightning incidence to overhead lines [J].
Chowdhuri, P ;
Mehairjan, S .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1997, 144 (02) :129-131
[44]   Transient induced voltages on aboveground pipelines parallel to overhead transmission lines [J].
Papadopoulos, T. A. ;
Datsios, Z. G. ;
Chrysochos, A. I. ;
Martins-Britto, A. G. ;
Papagiannis, G. K. .
ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223
[45]   INCREASING OF TRANSMISSION ABILITY AT HIGH VOLTAGE OVERHEAD LINES AMPACITY MODEL [J].
Vostracky, Zdenek ;
Piclova, Petra ;
Polivka, Jiri ;
Snajdr, Jaroslav ;
Krutina, Ales .
PROCEEDINGS OF THE 12TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2011, 2011, :53-56
[46]   Evaluation of Joule Power Losses Reduction in Overhead Lines with Innovative Conductors [J].
Benato, Roberto ;
Caldon, Roberto ;
Coppo, Massimiliano ;
Sessa, Sebastian Dambone ;
Rinzo, Giovanni ;
Mimo, Debora .
2018 AEIT INTERNATIONAL ANNUAL CONFERENCE, 2018,
[47]   Evaluation technology for the operational status of overhead lines based on a health index [J].
Gao F. ;
Liu Y. ;
Jia P. ;
Yang Y. .
Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (12) :167-176
[48]   Parameter determination for modeling system transients - Part I: Overhead lines [J].
Martinez, JA ;
Gustavsen, B ;
Durbak, D .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) :2038-2044
[49]   Databases Usage for Maintenance Optimization of 22 kV Overhead Power Lines [J].
Gono, Radomir ;
Rusek, Stanislav .
PROCEEDINGS OF THE 5TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2004, 2004, :197-200
[50]   Power Losses on Overhead Lines under Various Loading Regimes and Weather Conditions [J].
Baran, Ileana ;
Costea, Marian ;
Leonida, Tudor .
2017 5TH INTERNATIONAL SYMPOSIUM ON ELECTRICAL AND ELECTRONICS ENGINEERING (ISEEE), 2017,