Assessment of the accuracy of multiple sonographic fetal weight estimation formulas: A 10-year experience from a single center

被引:43
作者
机构
[1] Department of Obstetrics and Gynecology, Assaf Harofeh Medical Center
来源
Maymon, R. (maymonrb@bezeqint.net) | 1600年 / John Wiley and Sons Ltd卷 / 32期
关键词
Accuracy; Estimation; Fetal weight; Models; Sonography;
D O I
10.7863/ultra.32.5.815
中图分类号
学科分类号
摘要
Objectives-The primary aim of this study was to compare the accuracy of sonographic fetal weight estimation models. The secondary aim was to define the most accurate time (4-7 or 3 days before delivery) for evaluating fetal weight. Methods-In this retrospective cohort study, a total of 12,798 sonographic fetal weight estimations were analyzed, of which 9459 were performed within 3 days of delivery and 3339 within 4 to 7 days. The cohort included all singleton pregnancies recorded at a single medical center from January 2000 to December 2010, with 24 weeks' gestation minimum. Predicted birth weights were calculated according to 23 sonographic fetal weight estimation models; in total, 294,354 sonographic weight estimations were evaluated and compared to the actual birth weights. Results-The accuracy of the models in predicting birth weight differed considerably. The most accurate models used 3 or more fetal measurements followed by models using abdominal circumference only. The models developed by Sabbagha et al (Am J Obstet Gynecol 1989; 160:854-862) proved most accurate, with a mean percent error of-0.2% and greater than 92% of estimates within 15% of birth weight (P<.05). Nineteen sonographic fetal weight estimation models (82.6%) better predicted fetal weight at 4 to 7 days before delivery (P <.001). Twenty-two (95%) of the models were less accurate at the extreme ends of fetal weight. Conclusions-Different formulas for fetal weight estimation vary greatly; we recommend that each center should evaluate the most accurate formula according to its attending population. Estimation of fetal weight performed 4 to 7 days before delivery using most models was more accurate than estimations performed 3 days before delivery. © 2013 by the American Institute of Ultrasound in Medicine.
引用
收藏
页码:815 / 823
页数:8
相关论文
共 34 条
[1]  
Chauhan S.P., Cowan B.D., Magann E.F., Bradford T.H., Roberts W.E., Morrison J.C., Intrapartum detection of a macrosomic fetus: Clinical versus 8 sonographic models, Aust N Z J Obstet Gynaecol, 35, pp. 266-270, (1995)
[2]  
Hendrix N.W., Grady C.S., Chauhan S.P., Clinical vs. sonographic estimate of birth weight in term parturients: A randomized clinical trial, J Reprod Med, 45, pp. 317-322, (2000)
[3]  
Sherman D.J., Arieli S., Tovbin J., Siegel G., Caspi E., Bukovsky I., A comparison of clinical and ultrasonic estimation of fetal weight, Obstet Gynecol, 91, pp. 212-217, (1998)
[4]  
Dudley N.J., A systematic review of the ultrasound estimation of fetal weight, Ultrasound Obstet Gynecol, 25, pp. 80-89, (2005)
[5]  
Melamed N., Yogev Y., Meisner I., Mashiach R., Bardin R., Ben-Haroush A., Sonographic fetal weight estimation: Which model should be used?, J Ultrasound Med, 28, pp. 617-629, (2009)
[6]  
Nahum G.G., Stanislaw H., Ultrasonographic prediction of term birth weight: How accurate is it?, Am J Obstet Gynecol, 188, pp. 566-574, (2003)
[7]  
Ott W.J., Doyle S., Flamm S., Wittman J., Accurate ultrasonic estimation of fetal weight: Prospective analysis of new ultrasonic formulas, Am J Perina-tol, 3, pp. 307-310, (1986)
[8]  
Yarkoni S., Reece E.A., Wan M., Holford T., Romero R., Hobbins J.C., Intrapartum fetal weight estimation: A comparison of three formulas, J Ultrasound Med, 5, pp. 707-710, (1986)
[9]  
Jackson D.W., Pitts D.K., Kushner R., Estimation of fetal weight by means of ultrasound: A comparison of methods, J Am Osteopath Assoc, 90, pp. 1071-1080, (1990)
[10]  
Tongsong T., Piyamongkol W., Sreshthaputra O., Accuracy of ultrasonic fetal weight estimation: A comparison of three equations employed for estimating fetal weight, J Med Assoc Thai, 77, pp. 373-377, (1994)