Since a high degree of reliability is necessary for permanent magnet synchronous motors, the detection of a precursor for the demagnetization of permanent magnets is very important. This paper investigates the diagnosis of very slight PM demagnetization. The permanent magnet volume is altered so as to mimic the effect of demagnetization. This paper investigates the influence of demagnetization by using several methods: the 3D finite element analysis (FEA) of the motor, the measurement of high-frequency impedance, and the measurement and FEA of the stator voltage and current under vector control. We have obtained the following results. The back-EMF is proportional to permanent magnet volume, and there is no difference in the demagnetization in the radial direction and in the axial direction. Even harmonics and subharmonics of flux density at the teeth tip could be useful for diagnosis if a search coil is installed there. The relatively low frequency resistance at the d-axis position is useful for diagnosis. Under vector control, the stator voltage is useful except in an intermediate torque range, and the intermediate torque is expressed by a simple equation. © 2017 Takeo Ishikawa et al.
引用
收藏
相关论文
共 12 条
[1]  
Urresty J.-C., Riba J.-R., Delgado M., Romeral L., Detection of demagnetization faults in surface-mounted permanent magnet synchronous motors by means of the zero-sequence voltage component, IEEE Transactions on Energy Conversion, 27, 1, pp. 42-51, (2012)
[2]  
Rajagopalan S., Le R.W., Habetler T.G., Harley R.G., Diagnosis of potential rotor faults in brushless DC machines, Proceedings of the Second IEE International Conference on Power Electronics, Machines and Drives, 2, pp. 668-673, (2004)
[3]  
Espinosa A.G., Rosero J.A., Cusido J., Romeral L., Ortega J.A., Fault detection by means of Hilbert-Huang transform of the stator current in a PMSM with demagnetization, IEEE Transactions on Energy Conversion, 25, 2, pp. 312-318, (2010)
[4]  
Prieto M.D., Espinosa A.G., Riba Ruiz J.-R., Urresty J.C., Ortega J.A., Feature Extraction of demagnetization faults in permanent-magnet synchronous motors based on boxcounting fractal dimension, IEEE Transactions on Industrial Electronics, 58, 5, pp. 1594-1605, (2011)
[5]  
Urresty J.-C., Riba J.-R., Romeral L., A back-emf based method to detectmagnet failures inPMSMs, IEEE Transactions on Magnetics, 49, 1, pp. 591-598, (2013)
[6]  
Liu K., Zhu Z.Q., Online estimation of the rotor flux linkage and voltage-source inverter nonlinearity in permanent magnet synchronous machine drives, IEEE Transactions on Power Electronics, 29, 1, pp. 418-427, (2014)
[7]  
Wallscheid O., Huber T., Peters W., Bocker J., Realtime capable methods to determine the magnet temperature of permanent magnet synchronous motors - A review, Proceedings of the Industrial Electronics Society, IECON 2014 - 40th Annual Conference of the IEEE, pp. 811-818, (2014)
[8]  
Specht A., Wallscheid O., Bocker J., Determination of rotor temperature for an interior permanent magnet synchronous machine using a precise flux observer, Proceedings of the 7th International Power Electronics Conference, IPEC-Hiroshima - ECCE Asia 2014, pp. 1501-1507, (2014)
[9]  
Ganchev M., Kral C., Oberguggenberger H., Wolbank T., Sensorless rotor temperature estimation of permanent magnet synchronous motor, Proceedings of the 37th Annual Conference of the IEEE Industrial Electronics Society, IECON, 2011, pp. 2018-2023, (2011)
[10]  
Reigosa D.D., Briz F., Garcia P., Guerrero J.M., Degner M.W., Magnet temperature estimation in surface PM machines using high-frequency signal injection, IEEE Transactions on Industry Applications, 46, 4, pp. 1468-1475, (2010)