Experimental study on air source heat pump system with compressor frequency conversion and capillary

被引:0
作者
Niu J. [1 ,2 ]
Xu S. [1 ]
Liu S. [1 ]
Ma G. [1 ]
机构
[1] College of Environmental and Energy Engineering, Beijing University of Technology, Beijing
[2] College of Energy and Environmental Engineering, Hebei University of Architecture, Zhangjiakou, 075000, Hebei
来源
Huagong Xuebao/CIESC Journal | 2018年 / 69卷
关键词
Air source heat pump; Capillary; Compressor with frequency conversion; Heating performance;
D O I
10.11949/j.issn.0438-1157.20181130
中图分类号
学科分类号
摘要
Aiming at the household air source heat pump for "coal to electricity", a capillary as a throttle element is proposed to replace the thermal expansion valve or the electronic expansion valve, and an experimental device for heat pump system was set up. The influence of different capillary length on the compressor suction pressure, exhaust temperature and heat capacity of the unit under variable frequency regulation of compressor were experimentally studied. The experimental results show that, after replacing the thermal expansion valve or the electronic expansion valve, the system can run stably for a long time. The system has the best thermal performance when the capillary length is 500 mm and the compressor frequency is 35 Hz, and the heating capacity and heating COP are the largest, but the suction pressure and the exhaust temperature are moderate. © All Right Reserved.
引用
收藏
页码:180 / 185
页数:5
相关论文
共 30 条
[1]  
Gao Y., Tian H.Z., Zeng Y., Et al., Numerical simulation of two-phase flow in capillary-tubes, Fluid Machinery, 30, 7, pp. 47-49, (2002)
[2]  
Rao R.S., Zhou Z., Shen J.J., Et al., Capillary tube performance with R134a and R600a refrigerant, Refrigeration & Air-Conditioning, 5, 1, pp. 70-74, (2005)
[3]  
Bansal P.K., Rupasinghe A.S., An homogeneous model for adiabatic capillary tubes, Applied Thermal Engineering, 18, 3, pp. 207-219, (1998)
[4]  
Sun T., Guo X.M., Yang M., Effects of the capillary length on the dynamic performance of an air source heat pump water heater, Fluid Machinery, 37, 8, pp. 58-62, (2009)
[5]  
Guo X.M., Wang Y., Shen C., Et al., Experimental investigation on the transient performance of an exhaust air heat pump water heater, Fluid Machinery, 35, 3, pp. 55-59, (2007)
[6]  
Ji J., Chow T.T., Pei G., Et al., Domestic air conditioner and integrated water heater for subtropical climate, Applied Thermal Engineering, 23, 5, pp. 581-592, (2003)
[7]  
Ji J., Pei G., Chow T.T., Et al., Performance of multi-functional domestic heat pump system, Applied Energy, 80, 3, pp. 307-326, (2005)
[8]  
Wang L.Z., Cen M.T., Wang J.B., Study on capillary throttling characteristic of heat pump water heater under variable conditions, Fluid Machinery, 39, 6, pp. 74-79, (2011)
[9]  
Zhang C.L., Ding G.L., Li H., General integral model of two-phase flow in capillary tubes, Journal of Chemical Industry and Engineering (China), 50, 4, pp. 552-557, (1999)
[10]  
Ding G.L., Zhang C.L., Li H., Et al., Approximate analytical model for capillary flow, Chinese Science Bulletin, 43, 23, pp. 2506-2508, (1998)