A convergence adjustment method of power flow based on node type switching

被引:1
作者
Li, Zhihuan [1 ]
Han, Yunfei [2 ]
Su, Yinsheng [1 ]
Sun, Xin [2 ]
Huang, He [1 ]
Chen, Jinfu [2 ]
机构
[1] China Southern Power Grid Co. Ltd., Guangzhou
[2] State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan
来源
Dianli Xitong Zidonghua/Automation of Electric Power Systems | 2015年 / 39卷 / 07期
关键词
Convergence; Node type switching; Power flow calculation; Reactive power vacancy index;
D O I
10.7500/AEPS20140916001
中图分类号
学科分类号
摘要
The convergence adjustment of power flow plays an important role in the safe and economical operation of a power system. A convergence adjustment method of power flow based on node type switching is proposed to deal with the non-convergence situation of power flow calculation due to the imbalance of reactive power. In the case of non-convergence of power flow, all PQ nodes of the system are set to PV nodes and then these nodes are gradually recovered according to the proposed reactive power vacancy index. Finally, the nodes that cannot be recovered are determined, which provides an adjustment basis of power flow to the staff and lays a foundation for rationality adjustment of power flow. The analysis results of an IEEE 39-bus system and Shaoguan City system have verified the validity of the proposed algorithm and the adaptability of the large-scale power grid. ©2015 State Grid Electric Power Research Institute Press
引用
收藏
页码:188 / 193
页数:5
相关论文
共 11 条
  • [1] Li M., Chen J., Duan X., Et al., A study of load flow calculation when power flow does not converge to a solution, Relay, 34, 4, pp. 74-79, (2006)
  • [2] Iwamoto S., Tamura Y., A load flow calculation method for ill-conditioned power systems, IEEE Trans on Power Apparatus and Systems, 100, 4, pp. 1736-1743, (1981)
  • [3] Hu Z., Yan Z., Application of Newton load flow methods with optimal multiplier for AC/DC power systems, Automation of Electric Power Systems, 33, 9, pp. 26-31, (2009)
  • [4] Overbye T.J., A power flow measure for unsolvable cases, IEEE Trans on Power Systems, 9, 3, pp. 1359-1365, (1994)
  • [5] Overbye T.J., Computation of a practical method to restore power flow solvability, IEEE Trans on Power Systems, 10, 1, pp. 280-287, (1995)
  • [6] Jiang Q., Huang Z., Power-current hybrid power flow model based optimal power flow by interior point method, Automation of Electric Power Systems, 33, 12, pp. 32-37, (2009)
  • [7] Granville S., Mello J.C.O., Mello A.G.C., Application of interior point methods to power flow unsolvability, IEEE Trans on Power Systems, 11, 2, pp. 1096-1103, (1996)
  • [8] Li Y., Zhang B., Sun H., Et al., Security constrained optimal power flow based on nonlinear interior point method: Part one theory analysis, Automation of Electric Power Systems, 31, 19, pp. 7-13, (2007)
  • [9] Barboza L.V., Salgado R., Unsolvable power flow analysis-an approach based on interior point nonlinear optimization methods, Power Tech Proceedings, (2001)
  • [10] Zhou N., Zhong M., Xu G., Et al., Voltage stability index in power system based on voltage phasors, Proceedings of the CSEE, 17, 6, pp. 66-69, (1997)