Minimizing leakage inductor current RMS control strategy of bidirectional three-level DC-DC converter

被引:0
|
作者
Luo D. [1 ]
Shu Z. [1 ]
Lin H. [1 ]
Kuang Z. [1 ]
机构
[1] School of Electrical Engineering, Southwest Jiaotong University, Chengdu
关键词
DC-DC converters; Leakage inductor current of transformer; Minimizing leakage inductor current RMS control; Phase-shift control; Three-level half-bridge topology; Transmission efficiency;
D O I
10.16081/j.issn.1006-6047.2018.07.028
中图分类号
学科分类号
摘要
Aiming at the large stress of switching devices and low transmission efficiency of converter when the gene-ralized bidirectional isolated DC-DC converter with two-level H-bridge topology operates under the phase-shift control mode, a scheme with the minimizing inductor current RMS control based on the three-level half-bridge topology is proposed. The proposed scheme replaces the two-level H-bridge topology with three-level half-bridge topology, and adds the corresponding control for the leakage inductor current RMS of transformer to reduce the loss of converter and the stress of switching devices and improve the transmission efficiency of the converter. The control curve is plotted and deduced detailedly based on the expression of inductor current RMS and the condition of ZVS(Zero Voltage Switching), which is used to design the key controller based on FPGA. The experimental platform is established by using SiC MOSFET. The experimental results show that the converter can be improved in aspects of the voltage stress, switching loss and transmission efficiency, verifying the correctness and feasibility of the proposed scheme. © 2018, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:200 / 206
页数:6
相关论文
共 18 条
  • [1] Ma Y., Zong W., Liu L., Et al., GMD interference monitoring and denoising for electric system of high-speed railway, Electric Power Automation Equipment, 36, 3, pp. 165-168, (2016)
  • [2] Song X., Liu Z., Huang K., Electromagnetic transient influence of pantograph detachment arcing for traction network in high-speed railway based on state space analysis method, Electric Power Automation Equipment, 37, 12, pp. 184-191, (2017)
  • [3] Wu J., Wu W., Sun X., Application of series re-sonant dual active converter in distributed DC system, Electric Power Automation Equipment, 30, 5, pp. 96-101, (2010)
  • [4] Zhu F., Cheng B., Tan C., ZVS isolated high step-up DC-DC converter, Electric Power Automation Equipment, 35, 5, pp. 70-76, (2015)
  • [5] Zheng L., Li K., Wu P., Et al., Shunt zero-current full-bridge DC-DC converter, Electric Power Automation Equipment, 30, 1, pp. 62-67, (2010)
  • [6] Tian M., Wu J., Hao L., Et al., The soft starting control strategy on the multi port DC/DC converter of battery storage system, Power System Technology, 39, 9, pp. 2465-2472, (2015)
  • [7] Li H., Ji H., Fu B., Et al., Safe charge-discharge control stra-tegy for vanadium redox flow battery energy storage system with DC/DC converter, Automation of Electric Power Systems, 37, 24, pp. 7-11, (2013)
  • [8] Ding Z., Wang S., Zhou H., Et al., A transformer clamping DC/DC converter suitable for electric vehicle charger, Automation of Electric Power Systems, 34, 24, pp. 78-82, (2010)
  • [9] Hiltunen J., Vaisanen V., Juntunen R., Et al., Variable-fre-quency phase shift modulation of a dual active bridge converter, IEEE Transactions on Power Electronics, 30, 12, pp. 7138-7148, (2015)
  • [10] Krismer F., Kolar J.W., Efficiency-optimized high-current dual active bridge converter for automotive applications, IEEE Transactions on Industrial Electronics, 59, 7, pp. 2745-2760, (2012)