Analysis Мethods for Lightning Shielding Failure of Transmission Lines and Associated Applicability

被引:0
作者
He, Jinliang [1 ]
Zhuang, Chijie [1 ]
机构
[1] Department of Electrical Engineering, Tsinghua University, Haidian District, Beijing
来源
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering | 2024年 / 44卷 / 18期
关键词
applicability; electro-geometric model (EGM); leader propagation model; lightning protection; shielding failure; transmission line;
D O I
10.13334/j.0258-8013.pcsee.240391
中图分类号
学科分类号
摘要
Lightning striking has become the primary factor that threatens the safe and reliable operation of the power system, and the transmission lines with voltage levels of 500 kV and above are mainly affected by lightning shielding failure. On the basis of summarizing the development of electro-geometric model and to overcome the problem that electro-geometric models ignore most of the physical processes of lightning strikes, this paper provides a detailed analysis of the leader propagation model (LPM), including the physical process of lightning strikes on transmission lines, parameter selection of the model, numerical implementation, and model validation. The factors affecting the shielding failure of transmission lines are analyzed, and the applicability of different shielding failure analysis methods is discussed. For transmission lines with voltage levels of 500 kV and above, as well as multi circuit transmission lines on the same tower, the leader propagation model should be used to analyze the lightning shielding failure rate. This paper provides important technical support for lightning protection design and operation accident analysis of transmission lines. ©2024 Chin.Soc.for Elec.Eng.
引用
收藏
页码:7426 / 7439
页数:13
相关论文
共 55 条
  • [11] ARMSTRONG H R, WHITEHEAD E R., A lightning stroke pathfinder[J], IEEE Transactions on Power Apparatus and Systems, 83, 12, pp. 1223-1227, (1964)
  • [12] LI Yu, Lightning protection strategy of AC/DC EHV transmission lines, (2007)
  • [13] HUANG Yubin, CHEN Weijiang, HE Hengxin, Et al., A simplified model for estimation of electric field of positive leader in long air gaps, Proceedings of the CSEE, 43, 22, pp. 8977-8986, (2023)
  • [14] CHEN Shanshan, HE Hengxin, ZOU Yanhui, Et al., Distribution characteristics of corona space charge generated from the ∓1 100 kV UHVDC overhead transmission line under the thundercloud electric field, High Voltage Engineering, 44, 4, pp. 1367-1376, (2018)
  • [15] YUAN Tao, WANG Хiaotian, SIMA Wenxia, Et al., Space charge criterion of the initial streamer for the stable inception of positive upward leader under lightning strikes, Proceedings of the CSEE, 43, 14, pp. 5663-5673, (2023)
  • [16] CUI Yingzhe, ZHUANG Chijie, ZHOU Хuan, Et al., The dynamic expansion of leader discharge channels under positive voltage impulse with different rise times in long air gap:experimental observation and simulation results, Journal of Applied Physics, 125, 11, (2019)
  • [17] SHVEDOV V, PIVNEV E, DAVOYAN A R, Et al., Optical beaming of electrical discharges[J], Nature Communications, 11, 1, (2020)
  • [18] CUI Yingzhe, ZHUANG Chijie, ZHOU Хuan, Et al., Thermodynamic properties of negative discharge channels in a 1 m air gap measured by optical interferometry, IEEE Transactions on Plasma Science, 47, 5, pp. 1917-1925, (2019)
  • [19] TILLES J N, LIU Ningyu, STANLEY M A, Et al., Fast negative breakdown in thunderstorms[J], Nature Communications, 10, 1, (2019)
  • [20] ZHUANG Chijie, WANG Zezhong, ZENG Rong, Et al., Discharge characteristics of different lightning air terminals under composite voltages[J], Plasma Science and Technology, 21, 5, (2019)