Analysis Мethods for Lightning Shielding Failure of Transmission Lines and Associated Applicability

被引:0
作者
He, Jinliang [1 ]
Zhuang, Chijie [1 ]
机构
[1] Department of Electrical Engineering, Tsinghua University, Haidian District, Beijing
来源
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering | 2024年 / 44卷 / 18期
关键词
applicability; electro-geometric model (EGM); leader propagation model; lightning protection; shielding failure; transmission line;
D O I
10.13334/j.0258-8013.pcsee.240391
中图分类号
学科分类号
摘要
Lightning striking has become the primary factor that threatens the safe and reliable operation of the power system, and the transmission lines with voltage levels of 500 kV and above are mainly affected by lightning shielding failure. On the basis of summarizing the development of electro-geometric model and to overcome the problem that electro-geometric models ignore most of the physical processes of lightning strikes, this paper provides a detailed analysis of the leader propagation model (LPM), including the physical process of lightning strikes on transmission lines, parameter selection of the model, numerical implementation, and model validation. The factors affecting the shielding failure of transmission lines are analyzed, and the applicability of different shielding failure analysis methods is discussed. For transmission lines with voltage levels of 500 kV and above, as well as multi circuit transmission lines on the same tower, the leader propagation model should be used to analyze the lightning shielding failure rate. This paper provides important technical support for lightning protection design and operation accident analysis of transmission lines. ©2024 Chin.Soc.for Elec.Eng.
引用
收藏
页码:7426 / 7439
页数:13
相关论文
共 55 条
  • [1] Evaluation of lightning shielding analysis methods for EHV and UHV DC and AC transmission lines, (2017)
  • [2] HE Jinliang, Lightning protection of transmission lines
  • [3] ARMSTRONG H R, WHITEHEAD E R., Field and analytical studies of transmission line shielding[J], IEEE Transactions on Power Apparatus and Systems, PAS-87, 1, pp. 270-281, (1968)
  • [4] BROWN G W, WHITEHEAD E R., Field and analytical studies of transmission line shielding:part[J], IEEE Transactions on Power Apparatus and Systems, PAS-88, 5, pp. 617-626, (1969)
  • [5] ZHU Mumei, Calculation of protection range and shielding failure rate of overhead ground wire, Journal of Huazhong University of Technology, 5, 8, pp. 1-14, (1965)
  • [6] WANG Хiaoyu, Simulation experiment research on shielding failure of transmission lines, Journal of Huazhong University of Technology, 5, 8, pp. 15-38, (1965)
  • [7] GOLDE R H., The frequency of occurrence and the distribution of lightning flashes to transmission lines[J], Transactions of the American Institute of Electrical Engineers, 64, 12, pp. 902-910, (1945)
  • [8] GOLDE R H., The lightning conductor[J], Journal of the Franklin Institute, 283, 6, pp. 451-477, (1967)
  • [9] GOLDE R H., Lightning and tall structures, Proceedings of the Institution of Electrical Engineers, 125, 4, pp. 347-351, (1978)
  • [10] PRICE W S, BARTLETT S C, ZOBEL E S., Lightning and corona performance of 330-Kv lines on the american gas and electric and ohio valley electric corporation systems [includes discussion][J], Transactions of the American Institute of Electrical Engineers.Part III:Power Apparatus and Systems, 75, 3, pp. 583-597, (1956)