Analysis Мethods for Lightning Shielding Failure of Transmission Lines and Associated Applicability

被引:0
|
作者
He, Jinliang [1 ]
Zhuang, Chijie [1 ]
机构
[1] Department of Electrical Engineering, Tsinghua University, Haidian District, Beijing,100084, China
关键词
Electroforming - Failure rate - Fracture mechanics - Power transmission lines - Shielding - Structural dynamics;
D O I
10.13334/j.0258-8013.pcsee.240391
中图分类号
学科分类号
摘要
Lightning striking has become the primary factor that threatens the safe and reliable operation of the power system, and the transmission lines with voltage levels of 500 kV and above are mainly affected by lightning shielding failure. On the basis of summarizing the development of electro-geometric model and to overcome the problem that electro-geometric models ignore most of the physical processes of lightning strikes, this paper provides a detailed analysis of the leader propagation model (LPM), including the physical process of lightning strikes on transmission lines, parameter selection of the model, numerical implementation, and model validation. The factors affecting the shielding failure of transmission lines are analyzed, and the applicability of different shielding failure analysis methods is discussed. For transmission lines with voltage levels of 500 kV and above, as well as multi circuit transmission lines on the same tower, the leader propagation model should be used to analyze the lightning shielding failure rate. This paper provides important technical support for lightning protection design and operation accident analysis of transmission lines. ©2024 Chin.Soc.for Elec.Eng.
引用
收藏
页码:7426 / 7439
相关论文
共 50 条
  • [1] Lightning shielding failure analysis of UHVAC transmission lines with an improved EGM
    Yuan, Haiyan
    Fu, Zhengcal
    Wei, Bengang
    Du, Yaping
    HKIE Transactions Hong Kong Institution of Engineers, 2009, 16 (03): : 42 - 47
  • [2] Simulated analysis of lightning shielding failure performance of UHVAC transmission lines
    Yao, C. (yaochenguo@cqu.edu.cn), 2013, Science Press (39):
  • [3] New viewpoint about lightning shielding failure of UHVDC transmission lines
    School of Electric Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
    不详
    Gaodianya Jishu, 2006, 12 (142-145):
  • [4] SHIELDING OF TRANSMISSION LINES AGAINST LIGHTNING
    CHOWDHUR.P
    GROSS, ETB
    NEGREIRA, SP
    JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 1968, 286 (04): : 269 - &
  • [5] Analysis on Lightning Current and Position During Shielding Failure of High Voltage AC Transmission Lines
    Gu, Shan-qiang
    Yu, Zhan-qing
    Zhou, Xuan
    Wang, Ze-zhong
    Zhu, Tong
    Yan, Bi-wu
    He, Jin-liang
    Zeng, Rong
    Zhuang, Chi-jie
    INTERNATIONAL CONFERENCE ON SIMULATION, MODELLING AND MATHEMATICAL STATISTICS (SMMS 2015), 2015, : 139 - 146
  • [6] Analysis of lightning shielding failure proof level of UHV transmission lines considering corona influences
    Yuan, Hai-Yan
    Fu, Zheng-Cai
    Wei, Ben-Gang
    Sun, Wei
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2009, 29 (25): : 111 - 117
  • [7] Study on the lightning protection of shielding failure for 1000 kV UHV transmission lines
    Wuhan High Voltage Research Institute of SGCC, Wuhan 430074, China
    Gaodianya Jishu, 2006, 12 (52-54):
  • [8] Lightning Attachment Models and Maximum Shielding Failure Current: Application to Transmission Lines
    Mikropoulos, Pantelis N.
    Tsovilis, Thomas E.
    2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 1867 - 1874
  • [9] Fractal-based lightning model for shielding failure rate calculation of transmission lines
    Rahiminejad, Abolfazl
    Vahidi, Behrooz
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2018, 12 (06) : 719 - 725
  • [10] Lightning Shielding Analysis of EHV and UHV Transmission Lines : On the Effect of Terrain Topography
    Cuaran, Jose
    Roman, Francisco
    Becerra, Marley
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,