Internal model and feedforward composite control scheme design of the brushless doubly-fed generator back to back converter

被引:0
作者
机构
[1] College of Electrical and Automatic Engineering, Hefei University of Technology
[2] Department of Electrical Engineering, Tongling University
来源
Zhang, X. (honglf@ustc.edu.cn) | 1600年 / Automation of Electric Power Systems Press卷 / 37期
关键词
Back to back pulse width modulation converters; Brushless doubly-fed generator (BDFG); Feedforward control; Internal model control; Power-balancing; Small signal mode; Wind power;
D O I
10.7500/AEPS201112184
中图分类号
学科分类号
摘要
The back to back pulse width modulation converter has many advantages such as bidirectional power flow and adjustable power factor as AC-supply for doubly-fed wind power generator. When the generator-side converter working condition changes abruptly, the DC-link voltage will fluctuate significantly. To stabilize the dc bus voltage and decrease the capacitor capacity, a composite control scheme of both internal model decoupling control strategy and the load power feedforward control strategy is presented, in which the feedforward compensation can offset load disturbance. The design scheme is analyzed and compared in the small signal model and the simulation results in MATLAB/Simulink environment. It is verified that the composite control scheme can quickly realize DC voltage stability and greatly improve the control effect of the DC bus voltage. Theory and simulation prove the feasibility and effectiveness of the control scheme. © State Grid Electric Power Research Institute Press.
引用
收藏
页码:11 / 17
页数:6
相关论文
共 13 条
  • [1] Li J., Song J., Wang W., Modeling and dynamic simulation of variable speed wind turbine with large capacity, Proceedings of the CSEE, 24, 16, pp. 100-105, (2004)
  • [2] Wu X., Chai J., Wang X., Overview of ac excitation for variable speed constant frequency double fed wind power generator systems, Automation of Electric Power Systems, 28, 23, pp. 92-96, (2004)
  • [3] Yao J., Li H., Liao Y., Et al., An improved control strategy of limiting the DC-link voltage fluctuation for a doubly fed induction wind generator, IEEE Trans on Power Electronics, 23, 3, pp. 1205-1213, (2008)
  • [4] He Y., He M., Zhao R., Et al., Analysis on the frequency converter severed for the AC excitation of wind-power DFIG, Automation of Electric Power Systems, 30, 4, pp. 105-112, (2006)
  • [5] Yao J., Liao Y., Zhou Q., Et al., Stable control strategy on DC-link voltage in a dual PWM control AC excitation power systems, Automation of Electric Power Systems, 31, 21, pp. 63-66, (2007)
  • [6] Wang F., Jiang J., Research of power-balancing combined control scheme for back to back PWM converters used in the wind generator, Proceedings of the CSEE, 26, 22, pp. 134-139, (2006)
  • [7] Deng F., Cai X., Double closed-loop PWM rectifier based on internal model control, Power Electronics, 42, 6, pp. 60-62, (2008)
  • [8] Quan J., Wang C., Han C., Internal decoupling control of three-phase voltage source PWM rectifier, Power Electronics, 41, 7, pp. 14-16, (2007)
  • [9] Qin H., Pan Z., Yang J., The simulation study on strategy of cascade brushless variable-speed constant-frequency doubly-fed generator, Acta Energiae Solaris Sinica, 30, 5, pp. 565-571, (2009)
  • [10] Shao S., Abdi E., Barati F., Et al., Stator-flux-oriented vector control for brushless doubly fed induction generator, IEEE Trans on Industrial Electronics, 56, 10, pp. 4220-4228, (2009)