Evaluation of non-invasive detection of blood glucose using OCT

被引:2
|
作者
Xu Q.-S. [1 ]
Feng S. [1 ]
Ye D.-T. [1 ]
机构
[1] Biomedical Engineering Research Center, Tsinghua University
关键词
Blood glucose; Evaluation method; Measurement precision; Non-invasive detection; Optical Coherence Tomography(OCT);
D O I
10.3788/OPE.20101812.2688
中图分类号
学科分类号
摘要
To improve the evaluation method of non-invasive detection of blood glucose by Optical Coherence Tomography(OCT), a method combining the relative variance of OCT signal slope with the relative standard error was presented to evaluate the measurement effect and to obtain the theoretical precision of blood glucose detection. Firstly, the effect of the OCT confocal function on the blood glucose detection and the computing method of the relative error of OCT signal slope were given. Then, the relative variance and standard error of the OCT signal slope via a vivo experiment on 3 New Zealand rabbits were carried out to evaluate the non-invasive detection of blood glucose. Obtained results indicate that the relative variance and standard error of OCT signal slope are (3.7%)/mmol & 0.068, (3.4%)/mmol & 0.026, (0.93%)/mmol & 0.019, respectively, and the theoretical measuring precision of blood glucose detection are ±3.7 mmol, ±1.5 mmol and ±4.1 mmol, respectively. It concludes that the the evaluation method of combining the relative variance and standard error of OCT signal slope can greatly improve the theoretical measuring precision of blood glucose detection, and the larger the fitting interval is, the higher the measuring precision is.
引用
收藏
页码:2688 / 2694
页数:6
相关论文
共 13 条
  • [1] Feng S., Yuan K., Ye D., Precision of glucose measurement in intralipid suspensions with optical coherence tomography, SPIE, pp. 510-513, (2008)
  • [2] Zheng Y., Li G., Zhang T., Et al., Performance analysis of an optical coherence tomography system with special coating beam splitter, Opt. Precision Eng., 14, 6, pp. 1082-1087, (2006)
  • [3] Li G., Zhang T., Zheng Y., Et al., Calibration of phase shifter in spectral domain OCT system, Opt. Precision Eng., 16, 1, pp. 114-121, (2008)
  • [4] Zheng Y., Li G., Liu J.J., Et al., Correction algorithm of restriction of linear phase-shift in complex spectral OCT system, Opt. Precision Eng., 15, 5, pp. 753-759, (2007)
  • [5] Kinnunen M., Myllyl R., Jokela T., Et al., In vitro studies toward noninvasive glucose monitoring with optical coherence tomography, Applied Optics, 45, 10, (2006)
  • [6] Larin K., Motamedi M., Ashitkov T., Et al., Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: A pilot study, Physics in Medicine and Biology, 48, 10, (2003)
  • [7] Larin K., Eledrisi M., Motamedi M., Et al., Noninvasive blood glucose monitoring with optical coherence tomography: A pilot study in human subjects, Diabetes Care, 25, 12, (2002)
  • [8] Larin K., Ashitkov T., Larina I., Et al., Optical coherence tomography and noninvasive blood glucose monitoring: A review, SPIE, 5474, (2004)
  • [9] Feng S., Yuan K., Ye D., Effect of multiple scattering on measured signal losses using optical coherence tomography studied by monte carlo simulation, International Journal of Innovative Computing, Information and Control, 6, 3, pp. 4249-4262, (2010)
  • [10] Kholodnykh A., Petrova I., Larin K., Optimization of low coherence interferometry for quantitative analysis of tissue optical properties, SPIE, 4624, (2002)