On a sensitive optical sensor for hydrogen leak detection

被引:0
|
作者
机构
[1] Javahiraly, N.
[2] Perroton, C.
来源
Javahiraly, N. (n.javahiraly@unistra.fr) | 1600年 / Old City Publishing卷 / 33期
关键词
Hydrogen detection - Hydrogen leak detection - Reference signals - Sensor configurations - Spectral modulation - Transducer layers - Transverse electric polarized lights - Transverse-magnetic polarized lights;
D O I
暂无
中图分类号
学科分类号
摘要
In this new configuration a transducer layer is deposited on a core of a multimode fibre. We present the response of a Pd-surface plasmon resonance (SPR) multimode H2 sensor, where all the modes are equally excited in the optical fibre in order to decrease the effect of modal conversion. The spectral modulation of the light transmitted by the fibre allows to detect H2. The sensor is only sensitive to the transverse magnetic polarized light and the Transverse Electric polarized light can be used as a reference signal. The study of the sensitivity and time response is achieved for several sensor configurations. ©2016 Old City Publishing, Inc. Published by license under the OCP Science imprint, a member of the Old City Publishing Group.
引用
收藏
页码:4 / 6
相关论文
共 50 条
  • [21] HIGHLY SENSITIVE OPTICAL SENSOR SYSTEM FOR BLOOD LEAKAGE DETECTION
    UEDA, M
    ISHIKAWA, K
    JIE, C
    MIZUNO, S
    TOUMA, Y
    OPTICS AND LASERS IN ENGINEERING, 1994, 21 (05) : 307 - 316
  • [22] Sensitive Data Leak Detection Based on Boundary Detection
    Jia Xuefei
    Bu Ning
    Gao Shang
    Li Tao
    MODERN TECHNOLOGIES IN MATERIALS, MECHANICS AND INTELLIGENT SYSTEMS, 2014, 1049 : 1154 - +
  • [23] Highly Sensitive Hydrogen Sensor Based on an Optical Driven Nanofilm Resonator
    Luo, Junxian
    Liu, Shen
    Chen, Peijing
    Chen, Yanping
    Zhong, Junlan
    Wang, Yiping
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (25) : 29357 - 29365
  • [24] Highly sensitive optical fiber hydrogen detection in liquid environment
    Xie, Zihan
    Huang, Zhenlin
    Shi, Yufei
    Cao, Yunjie
    Dong, Jie
    Tian, Ruotong
    Shen, Changyu
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 106 : 1 - 7
  • [25] INCREASED SENSITIVITY OF LEAK DETECTION WITH HYDROGEN
    ALERS, GA
    JACOBS, JA
    MALMBERG, PR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1953, 24 (05): : 399 - 400
  • [26] Hydrogen flame hazards and leak detection
    Jenkins, Scott
    Chemical Engineering (United States), 2020, 126 (12):
  • [27] Novel peroxiredoxin-based sensor for sensitive detection of hydrogen peroxide
    Yang, Yuhong
    Zhou, Yao
    Li, Jingyi
    Yu, Haijun
    Takaya, Naoki
    Wang, Ping
    Zhou, Shengmin
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2019, 517 (02) : 260 - 265
  • [28] METHOD AND APPARATUS FOR HIGHLY SENSITIVE LEAK DETECTION
    KARPOV, VI
    LEVINA, LE
    MURAVEVA, LD
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (04): : 866 - &
  • [29] A sensitive hydrogen peroxide optical sensor based on polysaccharide stabilized silver nanoparticles
    Tagad, Chandrakant K.
    Kim, Hyeong U.
    Aiyer, R. C.
    More, Pooja
    Kim, Taesung
    Moh, Sang Hyun
    Kulkarni, Atul
    Sabharwal, Sushma G.
    RSC ADVANCES, 2013, 3 (45) : 22940 - 22943
  • [30] Highly Sensitive Athermal Optical Microring Sensor Based on Intensity Detection
    Yi, Huaxiang
    Citrin, David S.
    Zhou, Zhiping