A Piezoresistive-Based Contact Lens for Non-invasive Intraocular Pressure Measurement

被引:0
|
作者
Kumuda, S. [1 ,2 ]
Gandhi, Uma [1 ]
Mangalanathan, Umapathy [1 ]
Rajanna, K. [3 ]
Pandi, N. Veera [4 ]
机构
[1] Natl Inst Technol, Dept Instrumentat & Control Engn, Tiruchirappalli 620015, India
[2] BMS Coll Engn, Dept Elect & Instrumentat Engn, Bangalore 560019, India
[3] Indian Inst Sci, Dept Instrumentat & Appl Phys, Bangalore 560012, India
[4] Indian Inst Sci, Ctr Nano Sci & Engn, Bangalore 560012, India
来源
SENSING AND IMAGING | 2024年 / 25卷 / 01期
关键词
Intraocular pressure sensor; Glaucoma; Piezoresistive; Thin film sensor; Carbon conductive paste and graphene; SENSOR; GLAUCOMA; TEMPERATURE;
D O I
10.1007/s11220-024-00515-z
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The second most common cause of blindness in the world is glaucoma. A key glaucoma indicator that can be monitored to treat the condition is intraocular pressure (IOP). A contact lens with a piezoresistive sensor to detect IOP continuously and non-invasively is proposed in this work. Two different contact lenses were fabricated, one with a sensing material made of carbon conductive paste and the other with graphene conductive paste. A screen-printing technique, which is a simple and inexpensive thin film-based technology was used for the fabrication of contact lenses. The fabricated contact lenses were tested for their transparency, waterproofing, ohmic contact, and sensitivity toward temperature. Results indicated that carbon conductive contact lens exhibited a sensitivity of 62.575 ohm/mmHg with a linear correlation coefficient of r2 = 0.948. Conversely, the graphene conductive contact lens demonstrated a sensitivity of 44.43 ohm/mmHg with a linear correlation coefficient of r2 = 0.974. The fabricated contact lenses complied with the fundamental requirements for contact lenses by being flexible, thin, and wrapped in a biocompatible material with high transparency.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Intraocular pressure measurement with ocular response analyzer over soft contact lens
    Sapkota, Kishor
    Franco, Sandra
    Lira, Madalena
    CONTACT LENS & ANTERIOR EYE, 2014, 37 (06): : 415 - 419
  • [42] Non-invasive blood pressure measurement in dogs and cats
    Mandigers, P
    TIJDSCHRIFT VOOR DIERGENEESKUNDE, 2005, 130 (07) : 198 - 201
  • [43] Advances in Non-Invasive Blood Pressure Measurement Techniques
    Panula, Tuukka
    Sirkia, Jukka-Pekka
    Wong, David
    Kaisti, Matti
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2023, 16 : 424 - 438
  • [44] Non-invasive measurement of rapid blood pressure changes
    Raamat, R
    Toska, K
    Jagomägi, K
    Talts, J
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 889 - 892
  • [45] NON-INVASIVE MEASUREMENT OF CENTRAL VENOUS-PRESSURE
    WAYAND, W
    PIMPL, W
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1982, 357 (03): : 233 - 233
  • [46] Non-invasive technologies for intracranial pressure/volume measurement
    Ragauskas, A
    Petkus, V
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 259 - 262
  • [47] Non-invasive measurement of pressure gradients using ultrasound
    Olesen, Jacob Bjerring
    Traberg, Marie Sand
    Pihl, Michael Johannes
    Jensen, Jorgen Arendt
    MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [48] NON-INVASIVE MEASUREMENT OF VENTRICULAR PRESSURE THROUGHOUT SYSTOLE
    BOURGUIGNON, MH
    WAGNER, HN
    AMERICAN JOURNAL OF CARDIOLOGY, 1979, 44 (03): : 466 - 471
  • [49] Non-invasive blood pressure measurement in animals: Part 1-Techniques for measurement and validation of non-invasive devices
    Skelding, Alicia
    Valverde, Alexander
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2020, 61 (04): : 368 - 374
  • [50] Advances in Non-Invasive Blood Pressure Measurement Techniques
    Panula, Tuukka
    Sirkia, Jukka-Pekka
    Wong, David
    Kaisti, Matti
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2023, 16 : 424 - 438