A Piezoresistive-Based Contact Lens for Non-invasive Intraocular Pressure Measurement

被引:0
|
作者
Kumuda, S. [1 ,2 ]
Gandhi, Uma [1 ]
Mangalanathan, Umapathy [1 ]
Rajanna, K. [3 ]
Pandi, N. Veera [4 ]
机构
[1] Natl Inst Technol, Dept Instrumentat & Control Engn, Tiruchirappalli 620015, India
[2] BMS Coll Engn, Dept Elect & Instrumentat Engn, Bangalore 560019, India
[3] Indian Inst Sci, Dept Instrumentat & Appl Phys, Bangalore 560012, India
[4] Indian Inst Sci, Ctr Nano Sci & Engn, Bangalore 560012, India
来源
SENSING AND IMAGING | 2024年 / 25卷 / 01期
关键词
Intraocular pressure sensor; Glaucoma; Piezoresistive; Thin film sensor; Carbon conductive paste and graphene; SENSOR; GLAUCOMA; TEMPERATURE;
D O I
10.1007/s11220-024-00515-z
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The second most common cause of blindness in the world is glaucoma. A key glaucoma indicator that can be monitored to treat the condition is intraocular pressure (IOP). A contact lens with a piezoresistive sensor to detect IOP continuously and non-invasively is proposed in this work. Two different contact lenses were fabricated, one with a sensing material made of carbon conductive paste and the other with graphene conductive paste. A screen-printing technique, which is a simple and inexpensive thin film-based technology was used for the fabrication of contact lenses. The fabricated contact lenses were tested for their transparency, waterproofing, ohmic contact, and sensitivity toward temperature. Results indicated that carbon conductive contact lens exhibited a sensitivity of 62.575 ohm/mmHg with a linear correlation coefficient of r2 = 0.948. Conversely, the graphene conductive contact lens demonstrated a sensitivity of 44.43 ohm/mmHg with a linear correlation coefficient of r2 = 0.974. The fabricated contact lenses complied with the fundamental requirements for contact lenses by being flexible, thin, and wrapped in a biocompatible material with high transparency.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] NON-INVASIVE MEASUREMENT OF VENTRICULAR PRESSURE
    SOUTHON, FCG
    AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (03): : 592 - 592
  • [22] Non-invasive measurement of intracranial pressure
    Hartmann, A
    LANCET, 1998, 351 (9101): : 524 - 524
  • [23] Non-invasive Measurement of Portal Pressure
    Elmahdy A.M.
    Berzigotti A.
    Current Hepatology Reports, 2019, 18 (1) : 20 - 27
  • [24] Accuracy and sensitivity of two non-invasive tonometers for the measurement of intraocular pressure (IOP) in the mouse
    Filippopoulos, T
    Matsubara, A
    Danias, J
    Huang, W
    Mittag, TW
    Miller, JW
    Grosskreutz, CL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [25] Wireless, passive strain sensor in a doughnut-shaped contact lens for continuous non-invasive self-monitoring of intraocular pressure
    Kouhani, M. Hossein M.
    Wu, Jiajia
    Tavakoli, Arman
    Weber, Arthur J.
    Li, Wen
    LAB ON A CHIP, 2020, 20 (02) : 332 - 342
  • [26] On Imaging based Non-contact Tonometer for Intraocular Pressure Measurement
    Bhatt, Mahabaleswara Ram
    Rao, Shyam Vasudeva
    2013 IEEE POINT-OF-CARE HEALTHCARE TECHNOLOGIES (PHT), 2013, : 97 - 100
  • [27] A NON-INVASIVE TONOMETER IN THE MEASUREMENT OF THE EFFECTS OF PINDOLOL AND TIMOLOL ON INTRAOCULAR-PRESSURE IN NORMAL SUBJECTS
    ROWLEY, S
    STAUNTON, JE
    TOSCH, A
    STEWARTJONES, JH
    EDGAR, DF
    TURNER, P
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1981, 65 (08) : 536 - 538
  • [28] Non-invasive measurement of vitreous lactate concentration in a rabbit model of mechanically elevated intraocular pressure
    Ngumah, QC
    Buchthal, S
    Dacheux, RF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U110 - U110
  • [29] Assessment of the Triggerfish™ contact lens sensor for measurement of intraocular pressure variations
    Sunaric-Megevand, Gordana
    Leuenberger, Peter
    Preussner, Paul-Rolf
    ACTA OPHTHALMOLOGICA, 2014, 92 (05) : E414 - E415
  • [30] Evaluation of a Contact Lens-Embedded Sensor for Intraocular Pressure Measurement
    Twa, Michael D.
    Roberts, Cynthia J.
    Karol, Huikai J.
    Mahmoud, Ashraf M.
    Weber, Paul A.
    Small, Robert H.
    JOURNAL OF GLAUCOMA, 2010, 19 (06) : 382 - 390