A Piezoresistive-Based Contact Lens for Non-invasive Intraocular Pressure Measurement

被引:0
|
作者
Kumuda, S. [1 ,2 ]
Gandhi, Uma [1 ]
Mangalanathan, Umapathy [1 ]
Rajanna, K. [3 ]
Pandi, N. Veera [4 ]
机构
[1] Natl Inst Technol, Dept Instrumentat & Control Engn, Tiruchirappalli 620015, India
[2] BMS Coll Engn, Dept Elect & Instrumentat Engn, Bangalore 560019, India
[3] Indian Inst Sci, Dept Instrumentat & Appl Phys, Bangalore 560012, India
[4] Indian Inst Sci, Ctr Nano Sci & Engn, Bangalore 560012, India
来源
SENSING AND IMAGING | 2024年 / 25卷 / 01期
关键词
Intraocular pressure sensor; Glaucoma; Piezoresistive; Thin film sensor; Carbon conductive paste and graphene; SENSOR; GLAUCOMA; TEMPERATURE;
D O I
10.1007/s11220-024-00515-z
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The second most common cause of blindness in the world is glaucoma. A key glaucoma indicator that can be monitored to treat the condition is intraocular pressure (IOP). A contact lens with a piezoresistive sensor to detect IOP continuously and non-invasively is proposed in this work. Two different contact lenses were fabricated, one with a sensing material made of carbon conductive paste and the other with graphene conductive paste. A screen-printing technique, which is a simple and inexpensive thin film-based technology was used for the fabrication of contact lenses. The fabricated contact lenses were tested for their transparency, waterproofing, ohmic contact, and sensitivity toward temperature. Results indicated that carbon conductive contact lens exhibited a sensitivity of 62.575 ohm/mmHg with a linear correlation coefficient of r2 = 0.948. Conversely, the graphene conductive contact lens demonstrated a sensitivity of 44.43 ohm/mmHg with a linear correlation coefficient of r2 = 0.974. The fabricated contact lenses complied with the fundamental requirements for contact lenses by being flexible, thin, and wrapped in a biocompatible material with high transparency.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Non-invasive Intraocular pressure monitoring with contact lens
    Campigotto, Angelica
    Leahy, Stephane
    Zhao, Guowei
    Campbell, Robert J.
    Lai, Yongjun
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (09) : 1324 - 1328
  • [2] A contact lens promising for non-invasive continuous intraocular pressure monitoring
    Pang, Yu
    Li, Yuxing
    Wang, Xuefeng
    Qi, Chenjie
    Yang, Yi
    Ren, Tian-Ling
    RSC ADVANCES, 2019, 9 (09): : 5076 - 5082
  • [3] Non-invasive FBG-based contact lens for continuous intraocular pressure monitoring
    Kumuda, S.
    Uma, G.
    Umapathy, M.
    Anand, V. R.
    Ramanan, S. Raja
    Asokan, S.
    Rajanna, K.
    OPTICAL FIBER TECHNOLOGY, 2024, 84
  • [4] Wearable Contact Lens Sensor for Non-Invasive Continuous Monitoring of Intraocular Pressure
    Dou, Zhiqiang
    Tang, Jun
    Liu, Zhiduo
    Sun, Qigong
    Wang, Yang
    Li, Yamin
    Yuan, Miao
    Wu, Huijuan
    Wang, Yijun
    Pei, Weihua
    Chen, Hongda
    MICROMACHINES, 2021, 12 (02) : 1 - 12
  • [5] Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring
    Chen, Guo-Zhen
    Chan, Ion-Seng
    Lam, David C. C.
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 203 : 112 - 118
  • [6] Non-invasive intraocular pressure monitoring with a contact lens engineered with a nanostructured polymeric sensing film
    Laukhin, Vladimir
    Sanchez, Irene
    Moya, Ana
    Laukhina, Elena
    Martin, Raul
    Ussa, Fernando
    Rovira, Concepcio
    Guimera, Anton
    Villa, Rosa
    Aguilo, Jordi
    Pastor, Jose-Carlos
    Veciana, Jaume
    SENSORS AND ACTUATORS A-PHYSICAL, 2011, 170 (1-2) : 36 - 43
  • [7] High resolution non-invasive intraocular pressure monitoring by use of graphene woven fabrics on contact lens
    Zhang, Yushi
    Chen, Yufeng
    Man, Tianxing
    Huang, Dong
    Li, Xiao
    Zhu, Hongwei
    Li, Zhihong
    MICROSYSTEMS & NANOENGINEERING, 2019, 5 (1)
  • [8] Effect of variations of corneal physiology on novel non-invasive intraocular pressure monitoring soft contact lens
    Campigotto, Angelica
    Ralhan, Ankur
    Helgason, Rick
    Campbell, Robert J.
    Lai, Yongjun
    BIOMEDICAL MICRODEVICES, 2021, 23 (01)
  • [9] High resolution non-invasive intraocular pressure monitoring by use of graphene woven fabrics on contact lens
    Yushi Zhang
    Yufeng Chen
    Tianxing Man
    Dong Huang
    Xiao Li
    Hongwei Zhu
    Zhihong Li
    Microsystems & Nanoengineering, 5
  • [10] Effect of variations of corneal physiology on novel non-invasive intraocular pressure monitoring soft contact lens
    Angelica Campigotto
    Ankur Ralhan
    Rick Helgason
    Robert J. Campbell
    Yongjun Lai
    Biomedical Microdevices, 2021, 23