Construction of IEC 61850 system as benchmark and improving method of GOOSE reliability

被引:0
作者
Amau, Toru [1 ,2 ]
Saka, Yasutaka [2 ]
Nishiwaki, Kouichi [2 ]
Saiki, Yuichi [3 ]
Otani, Tetsuo [2 ,4 ]
Aoki, Mutsumi [2 ]
Ukai, Hiroyuki [2 ]
机构
[1] Chubu Electric Power Co., Inc., 1, Higashi-shincho, Higashi-ku, Nagoya
[2] Nagoya Institue of Technology, Gokiso-cho, Showa-ku, Nagoya
[3] MEIRYO DENSHI, 38-23, Higashi-Maeda, Asada-cho, Nisshin
[4] Central Research Institute of Electric Power Industry, 2-11-1, Iwado Kita, Komae
关键词
GOOSE; IEC; 61850; Transmission;
D O I
10.1541/ieejpes.134.783
中图分类号
学科分类号
摘要
Overseas utilities have been employing Substation Automation Systems (SAS) based on IEC 61850 in which Generic Object-Oriented Substation Event (GOOSE) provides a fast mechanism of transferring event data such as transfer trip. The GOOSE messages are required to be reliable enough to maintain electric supply reliability, even though off-the-shelf devices composing SAS have their fixed configurations about GOOSE. This paper proposes a method to improve reliability of GOOSE with redundant dispatchers and message retransmissions that can use the fixed configurations as is. It also describes experimental results using a test system dispatching GOOSE messages of transfer trip, and shows the advantage of our proposal. © 2014 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:783 / 790
页数:7
相关论文
共 7 条
[1]  
Ali I., Thomas M.S., GOOSE based Protection Scheme Implementation & Testing in Laboratory, Proc. IEEE PES Conf. on Innovative Smart Grid Technologies (ISGT) 2011, pp. 1-7, (2011)
[2]  
Sevov L., Zhao T., Volohh I., THE POWER OF IEC 61850 FOR BUS TRANSFER AND LOAD SHEDDING APPLICATIONS, Record of Conference Papers Industry Applications Society 58th Annual IEEE Petroleum and Chemical Industry Conference (PCIC) 2011, pp. 1-7, (2011)
[3]  
Tan J., Luan W., IEC 61850 Based Substation Automation System Architecture Design, Proc. IEEE Power and Energy Society General Meeting 2011, pp. 1-6, (2011)
[4]  
Sidhu T.S., Yin Y., Modelling and Simulation for Performance Evaluation of IEC 61850-Based Substation Communication Systems, IEEE Trans. Power Delivery, 22, 3, pp. 1482-1489, (2007)
[5]  
IEC, Communication Networks and Systems for Power Utility Automation - Part 8-1: Specific Communication Service Mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO /IEC 8802-3, (2011)
[6]  
SEL-2240 Axion Rugged Digital I/O, Analog Inputs, Current and Voltage Measurements and Control for Your Toughest Applications
[7]  
SIEMENS SIMATIC Automation System S7-400 CPU Specifications Reference Manual