One-Step Magneton Sputtering of Crystalline Cu-Doped TiO2 Coatings: Characterization and Antibacterial Activity

被引:0
作者
Nikolova, Maria P. [1 ]
Yousefi, Sadegh [2 ,3 ]
Handzhiyski, Yordan [4 ]
Apostolova, Margarita D. [4 ]
机构
[1] Univ Ruse Angel Kanchev, Dept Mat Sci & Technol, 8 Studentska Str, Ruse 7017, Bulgaria
[2] Minist Educ, Ferdows Dept Educ, Ferdows 9771853113, Iran
[3] Semnan Univ, Dept Met & Mat Sci, Semnan 3513119111, Iran
[4] Bulgarian Acad Sci, Roumen Tsanev Inst Mol Biol, Acad Georgi Bonchev Str,Bl 21, Sofia 1113, Bulgaria
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 20期
关键词
DC magnetron sputtering; copper-doped TiO2; substrate bias; anatase; rutile; E; coli; S; aureus; antibacterial properties; THIN-FILMS; COPPER; DEPOSITION; GROWTH; INTERFACE; INFECTION; OXIDE;
D O I
10.3390/app14209578
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Early biofilm formation could be inhibited by applying a thin biocompatible copper coating to reduce periprosthetic infections. In this study, we deposited crystalline Cu-doped TiO2 films using one-step DC magnetron sputtering in an oxygen atmosphere on a biased Ti6Al4V alloy without external heating. The bias voltage varied from -25 V to -100 V, and the resultant substrate temperature was measured. The deposited coatings were characterized using X-ray diffraction (XRD), scanning electron microscopy (SEM), microhardness, scratch and hydrophilicity tests, potentiodynamic polarization measurements, and antibacterial assays against S. aureus and E. coli. The findings demonstrated that when a higher negative bias is applied, the substrate temperature drops, and the anatase to rutile transformation is initiated without indicating obvious Cu-containing phases. The SEM images of the films showed spherical agglomerates with homogeneously distributed Cu with decreasing Cu content as the bias value increased. Higher bias results in the grain refinement of the thinning coatings with more lattice microstrain and more defects, together with an increase in water contact angles and hardness values. Samples biased at -75 V exhibited the highest adhesive strength between coatings and substrate, whereas the specimen biased at -50 V demonstrated higher corrosion resistance. Cu-containing TiO2 coatings with pure anatase phase composition and Cu concentrations of 2.62 wt.% demonstrated excellent bactericidal activity against both S. aureus and E. coli. The layers containing 2.34 wt.% Cu exhibited very good antibacterial properties against S. aureus, only. According to these findings, the produced copper-doped TiO2 coatings have high bactericidal qualities in vitro and may be used to prepare orthopaedic and dental implants in the future.
引用
收藏
页数:17
相关论文
共 47 条
  • [1] Rutile TiO2 thin films grown by reactive high power impulse magnetron sputtering
    Agnarsson, B.
    Magnus, F.
    Tryggvason, T. K.
    Ingason, A. S.
    Leosson, K.
    Olafsson, S.
    Gudmundsson, J. T.
    [J]. THIN SOLID FILMS, 2013, 545 : 445 - 450
  • [2] Enhanced Photocatalytic and Antibacterial Ability of Cu-Doped Anatase TiO2 Thin Films: Theory and Experiment
    Alotaibi, Abdullah M.
    Williamson, Benjamin A. D.
    Sathasivam, Sanjayan
    Kafizas, Andreas
    Alqahtani, Mahdi
    Sotelo-Vazquez, Carlos
    Buckeridge, John
    Wu, Jiang
    Nair, Sean P.
    Scanlon, David O.
    Parkin, Ivan P.
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (13) : 15348 - 15361
  • [3] Magnetron sputtering of transparent conductive zinc oxide: relation between the sputtering parameters and the electronic properties
    Ellmer, K
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2000, 33 (04) : R17 - R32
  • [4] Biocompatibility, corrosion resistance and antibacterial activity of TiO2/CuO coating on titanium
    He, Xiaojing
    Zhang, Guannan
    Wang, Xin
    Hang, Ruiqiang
    Huang, Xiaobo
    Qin, Lin
    Tang, Bin
    Zhang, Xiangyu
    [J]. CERAMICS INTERNATIONAL, 2017, 43 (18) : 16185 - 16195
  • [5] A novel antibacterial titania coating:: Metal ion toxicity and in vitro surface colonization
    Heidenau, F
    Mittelmeier, W
    Detsch, R
    Haenle, M
    Stenzel, F
    Ziegler, G
    Gollwitzer, H
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2005, 16 (10) : 883 - 888
  • [6] Pulsed laser deposition of copper and zinc doped hydroxyapatite coatings for biomedical applications
    Hidalgo-Robatto, B. M.
    Lopez-Alvarez, M.
    Azevedo, A. S.
    Dorado, J.
    Serra, J.
    Azevedo, N. F.
    Gonzalez, P.
    [J]. SURFACE & COATINGS TECHNOLOGY, 2018, 333 : 168 - 177
  • [7] Investigation of tantalum oxynitride for hard and anti-corrosive coating application in diluted hydrochloric acid solutions
    Hirpara, Jignesh
    Chawla, Vipin
    Chandra, Ramesh
    [J]. MATERIALS TODAY COMMUNICATIONS, 2020, 23 (23):
  • [8] Exploration of photo-catalytic activity of nano-hydroxyapatite based on the crystallographic parameters: Estimation of crystallite size using X-ray diffraction data
    Hossain, Md. Sahadat
    Sarkar, Shifa
    Tarannum, Sakabe
    Tuntun, Supanna Malek
    Mahmud, Monika
    Bin Mobarak, Mashrafi
    Ahmed, Samina
    [J]. JOURNAL OF SAUDI CHEMICAL SOCIETY, 2023, 27 (06)
  • [9] Biological properties of copper-doped biomaterials for orthopedic applications: A review of antibacterial, angiogenic and osteogenic aspects
    Jacobs, Aurelie
    Renaudin, Guillaume
    Forestier, Christiane
    Nedelec, Jean-Marie
    Descamps, Stephane
    [J]. ACTA BIOMATERIALIA, 2020, 117 : 21 - 39
  • [10] SOLUTIONS ABLE TO REPRODUCE INVIVO SURFACE-STRUCTURE CHANGES IN BIOACTIVE GLASS-CERAMIC A-W3
    KOKUBO, T
    KUSHITANI, H
    SAKKA, S
    KITSUGI, T
    YAMAMURO, T
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (06): : 721 - 734