Quantification of technetium-99 in wastewater by means of automated on-line extraction chromatography - anion-exchange chromatography - inductively coupled plasma-mass spectrometry

被引:0
作者
Horstmann, Maximilian [1 ]
Quarles Jr, C. Derrick [2 ]
Happel, Steffen [3 ]
Sperling, Michael [4 ]
Faust, Andreas [5 ]
Clases, David [6 ]
Karst, Uwe [1 ]
机构
[1] Univ Munster, Inst Inorgan & Analyt Chem, Munster, Germany
[2] Elemental Sci Inc, Omaha, NE USA
[3] TrisKem Int SAS, Bruz, France
[4] European Virtual Inst Speciat Anal EVISA, Munster, Germany
[5] European Inst Mol Imaging EIMI, Munster, Germany
[6] Karl Franzens Univ Graz, Inst Chem, Graz, Austria
关键词
ENVIRONMENTAL-SAMPLES; DILUTION ANALYSIS; ICP-MS; SEAWATER; TECHNETIUM; SEPARATION; SPECIATION; TUTORIAL;
D O I
10.1039/d4ja00270a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With more than 30 million medical applications annually, 99mTc is the most widely used radioisotope. Nevertheless, the discharge of 99mTc and its radioactive nuclear isomer 99Tc through medical facilities into the aqueous environments is mostly unknown. This is related to the low absolute Tc mass used in medical examinations and consequent trace levels of Tc emitted from respective facilities. In this work, a new approach employing automated on-line extraction chromatography and anion-exchange chromatography was developed and coupled to inductively coupled plasma-mass spectrometry. The extraction column was filled with TK201 resin to preconcentrate, purify and elute pertechnetate ([99Tc]TcO4-) as the most relevant Tc species. The eluting 99Tc fraction was focused and separated on an anion-exchange chromatography column and directly calibrated into a mass flow using an on-line isotope dilution-like approach named isobaric dilution analysis. To accommodate ultra-trace levels in strong matrices with high grades of particulate contamination, the automated method was complemented by a newly developed manual filtration and preconcentration workflow with TK201 impregnated filter disks, reaching a combined preconcentration factor as high as 4615. An aerosol desolvation nebulization system was used additionally to boost sensitivity, achieving an ultimate limit of detection (LOD) as low as 0.70 +/- 0.02 fg kg-1. As proof of concept, a wastewater sample from a retention basin of a local university hospital was collected. This wastewater contained 99Tc emitted in diagnostic procedures and levels were determined to be as low as 89 +/- 4 fg kg-1. Ultratrace concentrations of pertechnetate are determined by preconcentration on a dedicated resin and anion exchange chromatography with ICP-MS detection.
引用
收藏
页码:2774 / 2782
页数:9
相关论文
共 50 条
  • [41] Development of anion-exchange/reversed-phase high performance liquid chromatography-inductively coupled plasma-mass spectrometry methods for the speciation of bio-available iodine and bromine from edible seaweed
    Romaris-Hortas, Vanessa
    Bermejo-Barrera, Pilar
    Moreda-Pineiro, Antonio
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1236 : 164 - 176
  • [42] Speciation of Arsenic in Fish by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry
    Ozcan, Sefika
    Bakirdere, Sezgin
    Ataman, Osman Yavuz
    ANALYTICAL LETTERS, 2016, 49 (15) : 2501 - 2512
  • [43] Ion exchange chromatography coupled to inductively coupled plasma mass spectrometry for the study of Pt electro-dissolution
    Xing, Liyan
    Jerkiewicz, Gregory
    Beauchemin, Diane
    ANALYTICA CHIMICA ACTA, 2013, 785 : 16 - 21
  • [44] Quantification of Human Serum Transferrin Based on High Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry with Gold Nanoparticles Labeling
    Han, Ya-Chen
    Feng, Liu-Xing
    Li, Hong-Mei
    Xiong, Jin-Ping
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (02) : 206 - 214
  • [45] New separation method for organic and inorganic selenium compounds based on anion exchange chromatography followed by inductively coupled plasma mass spectrometry
    Ayouni, L.
    Barbier, F.
    Imbert, J. L.
    Gauvrit, J. Y.
    Lanteri, P.
    Grenier-Loustalot, M. F.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (08) : 1504 - 1512
  • [46] Speciation of Selenium in Enriched Garlic Sprouts by High-Performance Liquid Chromatography Coupled with Inductively Coupled Plasma-Mass Spectrometry
    Zhong, Na
    Zhong, Li
    Hao, Linhua
    Luan, Chengzhang
    Li, Xinrong
    ANALYTICAL LETTERS, 2015, 48 (01) : 180 - 187
  • [47] New separation method for organic and inorganic selenium compounds based on anion exchange chromatography followed by inductively coupled plasma mass spectrometry
    L. Ayouni
    F. Barbier
    J. L. Imbert
    J. Y. Gauvrit
    P. Lantéri
    M. F. Grenier-Loustalot
    Analytical and Bioanalytical Chemistry, 2006, 385 : 1504 - 1512
  • [48] Determination of fetogram plutonium by extraction chromatography using isotope dilution inductively coupled plasma mass spectrometry
    Jin, YR
    Zhang, LZ
    Han, SJ
    Zhu, FR
    Bai, JF
    Zhou, GQ
    Ma, F
    Zhang, LX
    ACTA CHIMICA SINICA, 2000, 58 (10) : 1291 - 1295
  • [49] Arsenic speciation in rice samples for trace level determination by high performance liquid chromatography-inductively coupled plasma-mass spectrometry
    Kara, Semih
    Chormey, Dotse Selali
    Saygilar, Ahmet
    Bakirdere, Sezgin
    FOOD CHEMISTRY, 2021, 356
  • [50] Analysis of mono-phosphate nucleotides as a potential method for quantification of DNA using high performance liquid chromatography–inductively coupled plasma-mass spectrometry
    Claire L. Camp
    Barry L. Sharp
    Helen J. Reid
    John Entwisle
    Heidi Goenaga-Infante
    Analytical and Bioanalytical Chemistry, 2012, 402 : 367 - 372