Quantification of technetium-99 in wastewater by means of automated on-line extraction chromatography - anion-exchange chromatography - inductively coupled plasma-mass spectrometry

被引:0
作者
Horstmann, Maximilian [1 ]
Quarles Jr, C. Derrick [2 ]
Happel, Steffen [3 ]
Sperling, Michael [4 ]
Faust, Andreas [5 ]
Clases, David [6 ]
Karst, Uwe [1 ]
机构
[1] Univ Munster, Inst Inorgan & Analyt Chem, Munster, Germany
[2] Elemental Sci Inc, Omaha, NE USA
[3] TrisKem Int SAS, Bruz, France
[4] European Virtual Inst Speciat Anal EVISA, Munster, Germany
[5] European Inst Mol Imaging EIMI, Munster, Germany
[6] Karl Franzens Univ Graz, Inst Chem, Graz, Austria
关键词
ENVIRONMENTAL-SAMPLES; DILUTION ANALYSIS; ICP-MS; SEAWATER; TECHNETIUM; SEPARATION; SPECIATION; TUTORIAL;
D O I
10.1039/d4ja00270a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With more than 30 million medical applications annually, 99mTc is the most widely used radioisotope. Nevertheless, the discharge of 99mTc and its radioactive nuclear isomer 99Tc through medical facilities into the aqueous environments is mostly unknown. This is related to the low absolute Tc mass used in medical examinations and consequent trace levels of Tc emitted from respective facilities. In this work, a new approach employing automated on-line extraction chromatography and anion-exchange chromatography was developed and coupled to inductively coupled plasma-mass spectrometry. The extraction column was filled with TK201 resin to preconcentrate, purify and elute pertechnetate ([99Tc]TcO4-) as the most relevant Tc species. The eluting 99Tc fraction was focused and separated on an anion-exchange chromatography column and directly calibrated into a mass flow using an on-line isotope dilution-like approach named isobaric dilution analysis. To accommodate ultra-trace levels in strong matrices with high grades of particulate contamination, the automated method was complemented by a newly developed manual filtration and preconcentration workflow with TK201 impregnated filter disks, reaching a combined preconcentration factor as high as 4615. An aerosol desolvation nebulization system was used additionally to boost sensitivity, achieving an ultimate limit of detection (LOD) as low as 0.70 +/- 0.02 fg kg-1. As proof of concept, a wastewater sample from a retention basin of a local university hospital was collected. This wastewater contained 99Tc emitted in diagnostic procedures and levels were determined to be as low as 89 +/- 4 fg kg-1. Ultratrace concentrations of pertechnetate are determined by preconcentration on a dedicated resin and anion exchange chromatography with ICP-MS detection.
引用
收藏
页码:2774 / 2782
页数:9
相关论文
共 50 条
  • [31] Microfluidic high performance liquid chromatography-chip hyphenation to inductively coupled plasma-mass spectrometry
    Bishop, David P.
    Blanes, Lucas
    Wilson, Alexander B.
    Wilbanks, Thor
    Killeen, Kevin
    Grimm, Rudolf
    Wenzel, Ross
    Major, Derek
    Macka, Mirek
    Clarke, David
    Schmid, Robin
    Cole, Nerida
    Doble, Philip A.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1497 : 64 - 69
  • [32] Speciation of Selenium in Supplements by High Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry
    Bakirdere, Sezgin
    Volkan, Muervet
    Ataman, O. Yavuz
    ANALYTICAL LETTERS, 2015, 48 (09) : 1511 - 1523
  • [33] Quantitative Separation of Unknown Organic-Metal Complexes by Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry
    Dewey, Christian
    Kaplan, Daniel I.
    Fendorf, Scott
    Boiteau, Rene M.
    ANALYTICAL CHEMISTRY, 2023, 95 (20) : 7960 - 7967
  • [34] Determination of 236U in environmental samples by single extraction chromatography coupled to triple-quadrupole inductively coupled plasma-mass spectrometry
    Yang, Guosheng
    Tazoe, Hirofumi
    Yamada, Masatoshi
    ANALYTICA CHIMICA ACTA, 2016, 944 : 44 - 50
  • [35] Speciation and quantification of organotin compounds in sediment and drinking water by isotope dilution liquid chromatography-inductively coupled plasma-mass spectrometry
    Bishop, David P.
    Hare, Dominic J.
    de Grazia, Adrian
    Fryer, Fred
    Doble, Philip A.
    ANALYTICAL METHODS, 2015, 7 (12) : 5012 - 5018
  • [36] Study on Speciation of Selenium in Animal Tissues Using High Performance Liquid Chromatography with On-line Detection by Inductively Coupled Plasma Mass Spectrometry
    Kurek, E.
    Ruszczynska, A.
    Wojciechowski, M.
    Czauderna, M.
    Bulska, E.
    CHEMIA ANALITYCZNA, 2009, 54 (01): : 43 - 57
  • [37] Characterization of phosphonate-based antiscalants used in drinking water treatment plants by anion-exchange chromatography coupled to electrospray ionization time-of-flight mass spectrometry and inductively coupled plasma mass spectrometry
    Armbruster, Dominic
    Mueller, Uwe
    Happel, Oliver
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1601 : 189 - 204
  • [38] Speciation of chromium by direct coupling of ion exchange chromatography with inductively coupled plasma mass spectrometry
    Barnowski, C
    Jakubowski, N
    Stuewer, D
    Broekaert, JAC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (10) : 1155 - 1161
  • [39] Determination of seven arsenic species in seafood by ion exchange chromatography coupled to inductively coupled plasma-mass spectrometry following microwave assisted extraction: Method validation and occurrence data
    Leufroy, Axelle
    Noel, Laurent
    Dufailly, Vincent
    Beauchemin, Diane
    Guerin, Thierry
    TALANTA, 2011, 83 (03) : 770 - 779
  • [40] Speciation of Arsenic in Fish by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry
    Ozcan, Sefika
    Bakirdere, Sezgin
    Ataman, Osman Yavuz
    ANALYTICAL LETTERS, 2016, 49 (15) : 2501 - 2512