Quantification of technetium-99 in wastewater by means of automated on-line extraction chromatography - anion-exchange chromatography - inductively coupled plasma-mass spectrometry

被引:0
|
作者
Horstmann, Maximilian [1 ]
Quarles Jr, C. Derrick [2 ]
Happel, Steffen [3 ]
Sperling, Michael [4 ]
Faust, Andreas [5 ]
Clases, David [6 ]
Karst, Uwe [1 ]
机构
[1] Univ Munster, Inst Inorgan & Analyt Chem, Munster, Germany
[2] Elemental Sci Inc, Omaha, NE USA
[3] TrisKem Int SAS, Bruz, France
[4] European Virtual Inst Speciat Anal EVISA, Munster, Germany
[5] European Inst Mol Imaging EIMI, Munster, Germany
[6] Karl Franzens Univ Graz, Inst Chem, Graz, Austria
关键词
ENVIRONMENTAL-SAMPLES; DILUTION ANALYSIS; ICP-MS; SEAWATER; TECHNETIUM; SEPARATION; SPECIATION; TUTORIAL;
D O I
10.1039/d4ja00270a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With more than 30 million medical applications annually, 99mTc is the most widely used radioisotope. Nevertheless, the discharge of 99mTc and its radioactive nuclear isomer 99Tc through medical facilities into the aqueous environments is mostly unknown. This is related to the low absolute Tc mass used in medical examinations and consequent trace levels of Tc emitted from respective facilities. In this work, a new approach employing automated on-line extraction chromatography and anion-exchange chromatography was developed and coupled to inductively coupled plasma-mass spectrometry. The extraction column was filled with TK201 resin to preconcentrate, purify and elute pertechnetate ([99Tc]TcO4-) as the most relevant Tc species. The eluting 99Tc fraction was focused and separated on an anion-exchange chromatography column and directly calibrated into a mass flow using an on-line isotope dilution-like approach named isobaric dilution analysis. To accommodate ultra-trace levels in strong matrices with high grades of particulate contamination, the automated method was complemented by a newly developed manual filtration and preconcentration workflow with TK201 impregnated filter disks, reaching a combined preconcentration factor as high as 4615. An aerosol desolvation nebulization system was used additionally to boost sensitivity, achieving an ultimate limit of detection (LOD) as low as 0.70 +/- 0.02 fg kg-1. As proof of concept, a wastewater sample from a retention basin of a local university hospital was collected. This wastewater contained 99Tc emitted in diagnostic procedures and levels were determined to be as low as 89 +/- 4 fg kg-1. Ultratrace concentrations of pertechnetate are determined by preconcentration on a dedicated resin and anion exchange chromatography with ICP-MS detection.
引用
收藏
页码:2774 / 2782
页数:9
相关论文
共 50 条
  • [21] Analysis of Radium-226 in High Salinity Wastewater from Unconventional Gas Extraction by Inductively Coupled Plasma-Mass Spectrometry
    Zhang, Tieyuan
    Bain, Daniel
    Hammack, Richard
    Vidic, Radisav D.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (05) : 2969 - 2976
  • [22] Applications of liquid chromatography-inductively coupled plasma-mass spectrometry in the biosciences: A tutorial review and recent developments
    Bishop, David P.
    Hare, Dominic J.
    Clases, David
    Doble, Philip A.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 104 : 11 - 21
  • [23] Arsenic speciation in water and biota samples at trace levels by ion chromatography inductively coupled plasma-mass spectrometry
    Firat, Merve
    Bakirdere, Sezgin
    Sel, Sabriye
    Chormey, Dotse Selali
    Elkiran, Omer
    Erulas, Fatih
    Turak, Fatma
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (07) : 684 - 693
  • [24] Coupling ion chromatography and inductively coupled plasma-mass spectrometry with ultrasonic nebulization for sulfur speciation in dry foods
    Chu, Wan-Ying
    Weng, Yu-Ming
    Jiang, Shiuh-Jen
    Sahayam, A. C.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 157 : 63 - 67
  • [25] Validation of a methodology to determine As(III) and As(V) in drinking water by anion exchange chromatography and inductively coupled plasma mass spectrometry
    Arias-Barrantes, Betzabel
    Urbina-Campos, Azucena
    Lorena Alvarado-Gamez, Ana
    REVISTA INTERNACIONAL DE CONTAMINACION AMBIENTAL, 2020, 36 (01): : 45 - 53
  • [26] Indirect ultra trace determination of aminopolycarboxylic acids in surface water using ion exchange chromatography coupled on-line to inductively coupled plasma mass spectrometry
    Knoell, Juergen
    Seubert, Andreas
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1270 : 219 - 224
  • [27] Rapid isolation of plutonium in environmental solid samples using sequential injection anion exchange chromatography followed by detection with inductively coupled plasma mass spectrometry
    Qiao, Jixin
    Hou, Xiaolin
    Roos, Per
    Miro, Manuel
    ANALYTICA CHIMICA ACTA, 2011, 685 (02) : 111 - 119
  • [28] Arsenic speciation by gradient anion exchange narrow bore ion chromatography and high resolution inductively coupled plasma mass spectrometry detection
    Ammann, Adrian A.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (14) : 2111 - 2116
  • [29] Sensitive determination of metalloprotein in salt-rich matrices by size exclusion chromatography coupled with inductively coupled plasma-mass spectrometry
    Tang, Yinyin
    Liu, Lihong
    Nong, Qiying
    Guo, Hua
    Zhou, Qinfei
    Wang, Dingyi
    Yin, Yongguang
    Shi, Jianbo
    He, Bin
    Hu, Ligang
    Jiang, Guibin
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1677
  • [30] On-line determination of arsenic species in seawater by selective hydride generation coupled with inductively coupled plasma-mass spectrometry
    Den, SJ
    Wei, WC
    Mierzwa, J
    Yang, MH
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2002, 49 (02) : 197 - 205