Quantification of technetium-99 in wastewater by means of automated on-line extraction chromatography - anion-exchange chromatography - inductively coupled plasma-mass spectrometry

被引:0
|
作者
Horstmann, Maximilian [1 ]
Quarles Jr, C. Derrick [2 ]
Happel, Steffen [3 ]
Sperling, Michael [4 ]
Faust, Andreas [5 ]
Clases, David [6 ]
Karst, Uwe [1 ]
机构
[1] Univ Munster, Inst Inorgan & Analyt Chem, Munster, Germany
[2] Elemental Sci Inc, Omaha, NE USA
[3] TrisKem Int SAS, Bruz, France
[4] European Virtual Inst Speciat Anal EVISA, Munster, Germany
[5] European Inst Mol Imaging EIMI, Munster, Germany
[6] Karl Franzens Univ Graz, Inst Chem, Graz, Austria
关键词
ENVIRONMENTAL-SAMPLES; DILUTION ANALYSIS; ICP-MS; SEAWATER; TECHNETIUM; SEPARATION; SPECIATION; TUTORIAL;
D O I
10.1039/d4ja00270a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With more than 30 million medical applications annually, 99mTc is the most widely used radioisotope. Nevertheless, the discharge of 99mTc and its radioactive nuclear isomer 99Tc through medical facilities into the aqueous environments is mostly unknown. This is related to the low absolute Tc mass used in medical examinations and consequent trace levels of Tc emitted from respective facilities. In this work, a new approach employing automated on-line extraction chromatography and anion-exchange chromatography was developed and coupled to inductively coupled plasma-mass spectrometry. The extraction column was filled with TK201 resin to preconcentrate, purify and elute pertechnetate ([99Tc]TcO4-) as the most relevant Tc species. The eluting 99Tc fraction was focused and separated on an anion-exchange chromatography column and directly calibrated into a mass flow using an on-line isotope dilution-like approach named isobaric dilution analysis. To accommodate ultra-trace levels in strong matrices with high grades of particulate contamination, the automated method was complemented by a newly developed manual filtration and preconcentration workflow with TK201 impregnated filter disks, reaching a combined preconcentration factor as high as 4615. An aerosol desolvation nebulization system was used additionally to boost sensitivity, achieving an ultimate limit of detection (LOD) as low as 0.70 +/- 0.02 fg kg-1. As proof of concept, a wastewater sample from a retention basin of a local university hospital was collected. This wastewater contained 99Tc emitted in diagnostic procedures and levels were determined to be as low as 89 +/- 4 fg kg-1. Ultratrace concentrations of pertechnetate are determined by preconcentration on a dedicated resin and anion exchange chromatography with ICP-MS detection.
引用
收藏
页码:2774 / 2782
页数:9
相关论文
共 50 条
  • [1] Speciation of arsenic in chicken meat by anion-exchange liquid chromatography with inductively coupled plasma-mass spectrometry
    Polatajko, A
    Szpunar, J
    JOURNAL OF AOAC INTERNATIONAL, 2004, 87 (01) : 233 - 237
  • [3] Quantification of [99Tc]TcO4- in urine by means of anion-exchange chromatography-aerosol desolvation nebulization-inductively coupled plasma-mass spectrometry
    Horstmann, Maximilian
    Quarles Jr, C. Derrick
    Happel, Steffen
    Sperling, Michael
    Faust, Andreas
    Rahbar, Kambiz
    Clases, David
    Karst, Uwe
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (11) : 2849 - 2858
  • [4] Determination of technetium-99 in aqueous samples by isotope dilution inductively coupled plasma-mass spectrometry
    Beals, DM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1996, 204 (02): : 253 - 263
  • [5] Quantification of [99Tc]TcO4- in urine by means of anion-exchange chromatography–aerosol desolvation nebulization–inductively coupled plasma–mass spectrometry
    Maximilian Horstmann
    C. Derrick Quarles
    Steffen Happel
    Michael Sperling
    Andreas Faust
    Kambiz Rahbar
    David Clases
    Uwe Karst
    Analytical and Bioanalytical Chemistry, 2024, 416 : 2849 - 2858
  • [6] On-line cleanup of blanks by electrochemically modulated liquid chromatography for inductively coupled plasma-mass spectrometry
    Hasan, T
    Gazda, D
    Porter, MD
    Houk, RS
    ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) : 63 - 68
  • [7] ANION-EXCHANGE FOR THE DETERMINATION OF ARSENIC AND SELENIUM BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    GOOSSENS, J
    MOENS, L
    DAMS, R
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) : 921 - 926
  • [8] Determination of technetium-99 in environmental samples by inductively coupled plasma mass spectrometry
    Morita, S.
    Kim, C.K.
    Takaku, Y.
    Seki, R.
    Ikeda, N.
    Applied Radiation and Isotopes, 1991, 42 (06):
  • [9] Rapid determination of technetium-99 by automatic solid phase extraction and inductively coupled plasma mass spectrometry
    Wu, Hsin-Chieh
    Su, Te-Yen
    Tsai, Tsuey-Lin
    Jong, Shiang-Bin
    Yang, Ming-Hui
    Tyan, Yu-Chang
    RSC ADVANCES, 2014, 4 (74): : 39226 - 39230
  • [10] Determination of strong binding chelators and their metal complexes by anion-exchange chromatography and inductively coupled plasma mass spectrometry
    Ammann, AA
    JOURNAL OF CHROMATOGRAPHY A, 2002, 947 (02) : 205 - 216