Effect of sprinkler on evacuation dynamics in compartment fire

被引:0
|
作者
Takeuchi, Yuki [1 ]
Yamamoto, Kazuhiro [1 ]
Nishiki, Shinnosuke [2 ]
机构
[1] Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Aichi,464-8603, Japan
[2] Graduate School of Science and Engineering, Kagoshima University, 1-21-40, Korimoto, Kagoshima,890-0065, Japan
关键词
Fire extinguishers - Fire protection - Numerical models - Hose - Dynamics - Explosions - Heat flux;
D O I
暂无
中图分类号
学科分类号
摘要
Since fire is one of the most serious disasters, we need to reduce the potential of damages such as injury and burn, which is mainly caused by high heat fluxes from the burning area with strong luminous flames, accidental explosions, and toxic species of CO and smoke. In order to mitigate these losses, it is important to consider the appropriate room design with exits in the building for setting the safe evacuation route, coupled with effective instruments of fire extinguishers and alarms. For example, a sprinkler is an instrument used to put out a small fire. According to the legislative requirement, a fire sprinkler system is needed in shared accommodation buildings such as hotels. In planning individual actions for safety and in evaluating the effective instruments, it is necessary to understand the phenomena in fire and construct the fire evacuation plan in advance. For this purpose, the establishment of appropriate safety guidelines is essential, and the prediction of evacuees' behaviors in case of fire is important. However, it may be impractical to demonstrate the real fire, because the experiments are expectedly huge and dangerous. To assess the sprinkler during evacuation dynamics, it could be fruitful to conduct a numerical simulation. In this study, we simulated the compartment fire by FDS (Fire Dynamics Simulator). We changed the amount of water and the placement of the sprinklers. Based on data of fire dynamics by FDS simulations, we carried out the evacuation simulation. We examined the effect of sprinklers on the evacuation dynamics in terms of the fire spread and the smoke flow. Then, we discussed the evacuation time and CO exposure time during fire evacuation.
引用
收藏
页码:21 / 28
相关论文
共 50 条
  • [1] Effects of a Sprinkler on Evacuation Dynamics in Fire
    Yamamoto, Kazuhiro
    Takeuchi, Yuki
    Nishiki, Shinnosuke
    COMPUTATION, 2015, 3 (02): : 274 - 284
  • [2] A Numerical Analysis of the Fire Characteristics after Sprinkler Activation in the Compartment Fire
    Khoat, Ho Trong
    Kim, Ji Tea
    Quoc, Tran Dang
    Kwark, Ji Hyun
    Ryou, Hong Sun
    ENERGIES, 2020, 13 (12)
  • [3] The effect of thermal radiation on the dynamics of flashover in a compartment fire
    Yuen, WW
    Han, S
    Chow, WK
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2003, 46 (04) : 528 - 538
  • [4] THE INTERACTION OF AN ISOLATED SPRINKLER SPRAY AND A 2-LAYER COMPARTMENT FIRE ENVIRONMENT
    COOPER, LY
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1995, 38 (04) : 679 - 690
  • [5] Measuring modified glass bulb sprinkler thermal response in plunge and compartment fire experiments
    Frank, Kevin
    Spearpoint, Michael
    Baker, Greg
    Wade, Colleen
    Collier, Peter
    Fleischmann, Charles
    FIRE SAFETY JOURNAL, 2017, 91 : 662 - 670
  • [6] Simulation of evacuation dynamics in fire by cellular automata
    Kokubo, Satoshi
    Yamamoto, Kazuhiro
    Yamashita, Hiroshi
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2008, 74 (12): : 2724 - 2730
  • [7] A simplified model of the effect of a fire sprinkler spray on a buoyant fire plume
    Schwille, John A.
    Lueptow, Richard M.
    JOURNAL OF FIRE PROTECTION ENGINEERING, 2006, 16 (02) : 131 - 153
  • [8] Fire sprinkler systems
    Reeves Journal, 1996, 76 (11):
  • [9] Evacuation dynamics with fire spreading based on cellular automaton
    Zheng, Ying
    Jia, Bin
    Li, Xin-Gang
    Zhu, Nuo
    PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2011, 390 (18-19) : 3147 - 3156
  • [10] Enhanced fire sprinkler system: Fiber optical monitoring of fire sprinkler heads
    Reimer, Vladislav
    Zhang, Zhenyu
    Jansen, Sander L.
    Angelmahr, Martin
    Schade, Wolfgang
    FIRE SAFETY JOURNAL, 2022, 127