Experimental study on retrofitting of 500 kV transmission tower against ice load

被引:0
|
作者
Xie, Qiang [1 ]
Sun, Li [1 ]
Zhang, Yong [2 ]
机构
[1] College of Civil Engineering, Tongji University, Yangpu District, Shanghai 200092, China
[2] East China Grid Company Limited, Huangpu District, Shanghai 200002, China
关键词
Deformation - Electric power transmission - Ice - Towers - Buckling - Outages - Load limits - Loads (forces) - Retrofitting - Diaphragms;
D O I
暂无
中图分类号
学科分类号
摘要
In order to develop an effective retrofitting scheme for increasing the load-carrying capacity of transmission tower against ice load, two pairs of subassemblages for power transmission tower were established based on a typical 500 kV transmission tower which was severely damaged during the ice disaster. Each pair was designed with current code; while an additional diaphragm was added to its counterpart as a measure of retrofitting. The comparative tests on mechanical behavior, failure pattern and ice load-carrying capacity of the structures were conducted. The favorable effect of adding diaphragm in terms of improving structural performance of tower subassemblages was investigated. FEM software ANSYS was employed to analyze the behavior of the subassemblages by using shell elements. The study revealed that after adding diaphragm the out-of-plane deformation in the joints of cross-bracings was reduced significantly. Buckling mode of the main member was transited from torsional-flexural buckling to flexural buckling. And for one-panel and two-panel tower subassemblages, the ultimate strength was increased by 18.3% and 17.6% respectively. The diaphragm comprehensively improved the mechanical performance of transmission tower structures by decreasing the unfavorable influence of torsion of main member, and together with inhibiting the out-of-plane deformation of diagonal braces. Adding diaphragm is an effective and practical retrofitting method for enhancing the ice load-carrying capacity of transmission tower structures. © 2011 Chin. Soc. for Elec. Eng.
引用
收藏
页码:108 / 114
相关论文
共 50 条
  • [31] A Novel Protection of Transmission Lines for Two ±500kV HVDC Systems Erected on the Same Tower
    Huang Min
    Wang Gang
    Luo Huihui
    Liang Yuansheng
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 3669 - 3674
  • [32] Analysis on 500kV Compact and Narrow Basal Transmission Tower in ANSYS Modeling and Dynamic Properties
    Xiao Qi
    Zhou Lingfeng
    Cai Jingsu
    PROCEEDINGS OF THE 2011 INTERNATIONAL CONFERENCE ON INFORMATICS, CYBERNETICS, AND COMPUTER ENGINEERING (ICCE2011), VOL 3: COMPUTER NETWORKS AND ELECTRONIC ENGINEERING, 2011, 112 : 671 - 678
  • [33] Analysis of ecological environment for 500kV four circuits power transmission lines on same tower
    Zhang, Bingyi
    Wang, Xiaohui
    Zhao, Min
    Zhao, Yisong
    Wang, Xiaoyan
    Feng, Guihong
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 764 - +
  • [34] Lightning performances for AC 500kV transmission lines with quadruple-circuit on single tower
    Chai, Yajing
    Zhou, Wenjun
    Xue, Li
    Liu, Xiaodong
    Su, Hongmei
    2007 COMPATIBILITY IN POWER ELECTRONICS, 2007, : 83 - 88
  • [35] Study of the Prevention Method of ±800 kV Transmission Tower Foundation Deviation
    Dong, Xinsheng
    Wen, Guanru
    Zhao, Mingguan
    Yang, Yang
    Li, Meng
    Zhao, Long
    ENERGIES, 2023, 16 (06)
  • [36] Analytical and experimental study on surge response of transmission tower
    Motoyama, H
    Matsubara, H
    IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (02) : 812 - 819
  • [37] Analytical and experimental study on surge response of transmission tower
    Motoyama, H
    Matsubara, F
    2000 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-4, 2000, : 855 - 855
  • [38] Research on DC Ice-melting Technologies for 500kV AC Transmission Lines
    Hao, Weiwei
    Peng, Shurong
    Lu, Jiazheng
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1663 - 1666
  • [39] Ice-shedding characteristic of 1000 kV AC double circuit transmission line on the same tower
    Hu, Wei
    Chen, Yong
    Cai, Wei
    Meng, Xiao-Bo
    Wang, Li-Ming
    Fu, Guan-Jun
    Zhu, Pu-Xuan
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (01): : 275 - 280
  • [40] Study on Wind-induced Vibration Coefficients of the Transmission Tower in 500kV Long Span Line Crossing the Yangtze River
    Yang F.
    Chen B.
    Xu Z.
    Xu Q.
    Shao S.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (07): : 2542 - 2555