Flexural bearing capacity of T-shaped joints in GFRP transmission towers

被引:0
|
作者
Chen Y. [1 ]
Xu J. [1 ]
Xie F. [2 ]
Feng B. [3 ]
Wang H. [4 ]
Shen G. [1 ]
机构
[1] College of Civil Engineering and Architecture, Zhejiang University, Hangzhou
[2] School of Civil Engineering, Shaoxing University, Shaoxing
[3] Shaoxing Daming Electric Power Design Institute CO., LTD., Shaoxing
[4] Hangzhou Yunqi Commercial Group CO., LTD., Hangzhou
基金
中国国家自然科学基金;
关键词
calculation formula; experimental study; flexural capacity; GFRP connections; mechanical properties;
D O I
10.13801/j.cnki.fhclxb.20230810.003
中图分类号
学科分类号
摘要
The integrally formed glass fiber reinforced polymer (GFRP) connection is the key structural component of the transmission tower's GFRP line-suspension module, requiring investigation into its capacities. Initially, two typical connections were examined experimentally, yielding mechanical properties including load-displacement curves and failure modes. Subsequently, a finite element model based on progressive damage evolution was established. Using the experimentally validated model, sensitivity analyses on the flexural capacity in relation to parameters such as the ratio of tensile strength Yt in the direction of the fiber to shear strength SL, the ratio of main tube diameter D to thickness T, the connection beam width B, and thickness w were conducted. Based on Hashin's failure criterion and regression analysis, an approximating equation for the connection's flexural capacity was derived, followed by a reliability analysis. The results indicate a good consistency between the experimental and the finite element analysis (FEA) results. The primary failure mode is the tension fracture of the matrix of the GFRP main tube near the connection. With increasing Yt/SL, the location of failure moves from the connection to the middle of the main tube gradually, showing a corresponding decrease in load-bearing capacity. The mean value and the coefficient of variation of the ratio of approximated capacity to FEA result are 1.032 and 6.80% respectively, and the flexural capacity derived for design has an assurance rate of 99.9%. © 2024 Beijing University of Aeronautics and Astronautics (BUAA). All rights reserved.
引用
收藏
页码:2609 / 2622
页数:13
相关论文
共 34 条
  • [11] MA Hui, LIU Yunhe, GUO Hongchao, Et al., Experimental research on mechanical properties of cross arm system using FRP composite material under two-way loads, Journal of Xi'an University of Technology, 31, 2, pp. 164-170, (2015)
  • [12] REN Zongdong, LIU Quan, MO Zenglu, Joint design and optimization of FRB tower[J], Electric Power Construction, 32, 4, pp. 87-91, (2011)
  • [13] WU Xiong, CAI Wei, LI Jian, Et al., Application progress of power fiber reinforced composite materials, Composites Science and Engineering, 11, pp. 116-128, (2021)
  • [14] ASYRAF M R M, ISHAK M R, SAPUAN S M, Et al., Utilization of bracing arms as additional reinforcement in pultruded glass fiber-reinforced polymer composite cross-arms: Creep experimental and numerical analyses[J], Polymers, 13, 4, (2021)
  • [15] SYAMSIR A, EAN L W, ASYRAF M R M, Et al., Recent advances of GFRP composite cross arms in energy transmission tower: A short review on design improvements and mechanical properties[J], Materials, 16, 7, (2023)
  • [16] HE Changlin, SHEN Fan, KE Rui, Et al., Application of composite insulated crossarm in the reconstruction project of 110 kV transmission line[J], Insulators and Surge Arresters, 2023, 2, pp. 157-163
  • [17] Researchoncompositecross-arm tower of 500 kV double circuit transmission line[J], Electric Power Survey & Design, 2023, 2, pp. 57-61
  • [18] BANK L C, MOSALLAM A S, MCCOY G T., Design and performance of connections for pultruded frame structures[J], Journal of Reinforced Plastics and Composites, 13, 3, pp. 199-212, (1994)
  • [19] MOSALLAM A S, ABDELHAMID M K, CONWAY J H., Performance of pultruded FRP connections under static and dynamic loads[J], Journal of Reinforced Plastics and Composites, 13, 5, pp. 386-407, (1994)
  • [20] SMITH S J, PARSONS I D, HJELMSTAD K D., An experimental study of the behavior of connections for pultruded GFRP I-beams and rectangular tubes[J], Composite Structures, 42, 3, pp. 281-290, (1998)