Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography

被引:0
|
作者
Egbe N.O. [1 ]
Akintomide A.O. [2 ]
Inah G.B. [2 ]
Owolo E. [1 ]
机构
[1] Department of Radiography & Radiological Science, University of Calabar
[2] Department of Radiology, University of Calabar, Calabar
关键词
Chest; Film; Image Quality; Pediatric; Radiation Dose; X-ray;
D O I
10.22038/IJMP.2016.7141
中图分类号
学科分类号
摘要
Introduction Over the years, the consequences of ionizing radiation have prompted major efforts towards producing radiographs of acceptable quality with dose values in compliance with safety standards and the ALARA principle. The aim of this study is to assess the compliance of radiation dose and image quality in a major Nigerian teaching hospital to the guidelines established by the Commission of European Communities (CEC) on optimized pediatric radiography. Materials and Methods The entrance skin dose (ESD) and image quality were studied among pediatric patients (age range: 0–15 years), referred to the hospital for chest radiographic examinations. Radiographic exposure factors were recorded in each examination. ESD was determined using a dose calculation software program (DoseCal®). The calculated ESD values were weighed against the CEC recommended doses and compared among different age groups through mean comparison. Based on the CEC image quality criteria, the resulting chest radiographs were assessed in terms of image quality. Results The overall image quality was high in over 70% of images (Fleiss’ kappa=0.63). The obtained ESD values were higher than the recommended CEC values (80 and 100 μGy for children aged 0-1 and 5 years, respectively). Also, the ESD values were higher than the recommended values by 26% in the age group of 0– 1 year and 9-10% in the other age groups. However, there was no significant difference between the age groups in terms of radiation dose. Conclusion The findings show that a considerable reduction in radiographic exposure factors (or doses) could still produce images with an acceptable diagnostic quality. This dose reduction could be achieved by reducing mAs, increasing kVp and adopting high-performance X-ray generators © 2016, Iranian Journal of Medical Physics.All Rights Reserved.
引用
收藏
页码:17 / 24
页数:7
相关论文
共 17 条
  • [1] Conceptus radiation dose and risk from chest screen-film radiography
    Damilakis, J
    Perisinakis, K
    Prassopoulos, P
    Dimovasili, E
    Varveris, H
    Gourtsoyiannis, N
    EUROPEAN RADIOLOGY, 2003, 13 (02) : 406 - 412
  • [2] SCREEN-FILM VERSUS FULL-FIELD DIGITAL MAMMOGRAPHY: RADIATION DOSE AND IMAGE QUALITY IN A LARGE TEACHING HOSPITAL
    Stantic, Tomislav J.
    Ciraj-Bjelac, Olivera E.
    Stojanovic, Saida S.
    Basta-Nikolic, Marijana D.
    Arandjic, Danijela D.
    Stoiljkovic, Dragana S.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2013, 28 (04) : 398 - 405
  • [3] Efficacy of Increasing Focus to Film Distance (FFD) for Patient's Dose and Image Quality in Pediatric Chest Radiography
    Karami, Vahid
    Zabihzadeh, Mansour
    Danyaei, Amir
    Shams, Nasim
    INTERNATIONAL JOURNAL OF PEDIATRICS-MASHHAD, 2016, 4 (09): : 3421 - 3429
  • [4] COMPARISON OF THE IMAGE QUALITY OF A HIGH-RESOLUTION SCREEN-FILM SYSTEM AND A DIGITAL FLAT PANEL DETECTOR SYSTEM IN AVIAN RADIOGRAPHY
    Bochmann, Monika
    Ludewig, Eberhard
    Krautwald-Junghanns, Maria-Elisabeth
    Pees, Michael
    VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (03) : 256 - 261
  • [5] Optimization of image quality and dose in adult and pediatric chest radiography via Monte Carlo simulation and experimental methods
    Mendes, Hitalo R.
    Silva, Julio C.
    Marcondes, Mariana
    Tomal, Alessandra
    RADIATION PHYSICS AND CHEMISTRY, 2022, 201
  • [6] A COMPARISON OF IMAGE QUALITY AND DOSE REQUIREMENTS OF A NEW CONVENTIONAL FILM-SCREEN SYSTEM FOR SKELETAL RADIOGRAPHY
    FREITAG, P
    GUCKEL, C
    FOURNIER, PJ
    ROTH, J
    STEINBRICH, W
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 163 (04): : 297 - 302
  • [7] MULTIPLE-BEAM EQUALIZATION RADIOGRAPHY IN CHEST RADIOLOGY - IMAGE QUALITY AND RADIATION-DOSE CONSIDERATIONS
    AXELSSON, B
    FORSBERG, H
    HANSSON, B
    HAVERLING, M
    ACTA RADIOLOGICA, 1991, 32 (01) : 12 - 17
  • [8] High-Pitch Spiral Computed Tomography Effect on Image Quality and Radiation Dose in Pediatric Chest Computed Tomography
    Lell, Michael M.
    May, Matthias
    Deak, Paul
    Alibek, Sedat
    Kuefner, Michael
    Kuettner, Axel
    Koehler, Henrik
    Achenbach, Stephan
    Uder, Michael
    Radkow, Tanja
    INVESTIGATIVE RADIOLOGY, 2011, 46 (02) : 116 - 123
  • [9] Optimizing Imaging Quality and Radiation Dose by the Age-Dependent Setting of Tube Voltage in Pediatric Chest Digital Radiography
    Guo, Hui
    Liu, Wen-Ya
    He, Xiao-Ye
    Zhou, Xiao-Shan
    Zeng, Qun-Li
    Li, Bai-Yan
    KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (01) : 126 - 131
  • [10] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Yoon, Haesung
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Choi, Jiin
    Shin, Hyun Joo
    Kim, Hyun Gi
    Lee, Mi-Jung
    PEDIATRIC RADIOLOGY, 2015, 45 (03) : 337 - 344