Analysis of the influence of ambient conditions on the ampacity of Kevlar-armoured subsea power cables

被引:3
|
作者
Vedachalam N. [1 ]
Umapathy A. [1 ]
Ramadass G.A. [1 ]
Atmanand M.A. [1 ]
机构
[1] National Institute of Ocean Technology, Ministry of Earth Sciences, Chennai
来源
Underwater Technology | 2017年 / 34卷 / 02期
关键词
Ampacity; Cables; Finite element analysis; Kevlar armour;
D O I
10.3723/ut.34.075
中图分类号
学科分类号
摘要
This paper presents the electro-thermal modelling and simulation, done on a standard Kevlar-armored subsea electrooptic cable based on the finite element analysis (FEA) approach, to determine the cable ampacity when operated in air, water and buried in the seabed under the relevant ambient environmental conditions. Compared to the ampacity in air at 30 ºC, the ampacities in air, water with no flow condition and seabed buried conditions with a thermal conductivity of 0.8 W/m-k could be 1.37 times, 1.57 times and 1.5 times, respectively, at an ambient temperature of 5 ºC; and the same could be 1.13 and 1.36 and 1.31 times, respectively, at 20 ºC. Under the influence of convective ambient flow fields, the ampacities could be increased only up to a maximum of 9% and 3%, with air and water flows of 20 m/s and 5 m/s, respectively. The results serve as a guideline for determining the cable ampacities for various environmental applications, based on the available cable current rating under specified ambient operating conditions. © 2017, Society for Underwater Technology. All rights reserved.
引用
收藏
页码:75 / 82
页数:7
相关论文
共 6 条
  • [1] Influence of Different Types of Magnetic Shields on the Thermal Behavior and Ampacity of Underground Power Cables
    del Pino Lopez, Juan Carlos
    Cruz Romero, Pedro
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) : 2659 - 2667
  • [2] Finite Element Analysis on the Overload and Short Circuit Ampacities of Kevlar Armored Subsea Power Cable
    Vedachalam, Narayanaswamy
    Umapathy, Arunachalam
    Ramadass, Gidugu Ananda
    MARINE TECHNOLOGY SOCIETY JOURNAL, 2017, 51 (03) : 36 - 42
  • [3] Ampacity Derating Analysis of Winch-Wound Power Cables: A Study Based on Deep-Water ROV Umbilical
    Vedachalam, Narayanaswamy
    Umapathy, Arunachalam
    Ramesh, Raju
    Babu, Sethuram Muthukrishna
    Muthukumaran, Durairaj
    Subramanian, Annamalai
    Harikrishnan, Gopalakrishnan
    Ramadass, Gidugu Ananda
    Atmanand, Malayath Aravindakshan
    IEEE JOURNAL OF OCEANIC ENGINEERING, 2016, 41 (02) : 462 - 470
  • [4] Thermal analysis of the influence of harmonics on the current capacity of medium-voltage underground power cables
    Gouda, Osama E.
    El Dein, Adel Z.
    Tag-Eldin, Elsayed
    Lehtonen, Matti
    Darwish, Mohamed M. F.
    ENERGY SCIENCE & ENGINEERING, 2023, 11 (10) : 3471 - 3485
  • [5] Enhancement of the thermal analysis of power cables installed in polyvinyl chloride (PVC) ducts under continuous and cyclic current loading conditions
    Gouda, Ossama E.
    Osman, Gomaa F. A.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2021, 15 (07) : 1144 - 1158
  • [6] Harmonic-based thermal analysis of electric arc furnace's power cables considering even current harmonics, forced convection, operational scheduling, and environmental conditions
    Jamali-Abnavi, Ahmadreza
    Hashemi-Dezaki, Hamed
    Ahmadi, Abdorrasoul
    Mahdavimanesh, Ehsan
    Tavakoli, Mohammad-Jafar
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 170