A two-stage coordinated restoration scheme of hybrid AC/DC distribution grid considering cold load pickup and resilience enhancement

被引:0
|
作者
Yu, Hang [1 ,2 ,3 ]
Xiao, Fu [1 ,2 ]
Zhang, Hanbei [1 ,2 ]
Liao, Wei [1 ,2 ]
Li, Yanxue [1 ,2 ,4 ]
机构
[1] Hong Kong Polytech Univ, Fac Construct & Environm, Hung Hom, 8 Hung Lok Rd, Hong Kong, Peoples R China
[2] Hong KongPolytechn Univ, Dept Bldg Environm & Energy Engn, Kowloon, Hung Hom, 8 Hung Lok Rd, Hong Kong, Peoples R China
[3] Wuhan Univ Technol, Sch Naval Architecture Ocean & Energy Power Engn, Wuhan, Hubei, Peoples R China
[4] Qingdao Univ Technol, Innovat Inst Sustainable Maritime Architecture Res, Qingdao 266033, Peoples R China
关键词
Cold load pickup (CLPU); Grid resilience; Hybrid AC/DC distribution grid; Load restoration; Buildings; SERVICE RESTORATION; DISTRIBUTION-SYSTEMS; TIME;
D O I
10.1016/j.scs.2024.105959
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The ever-increasingly severe weather events have elevated the quest for resilience in distribution grids. Cold load pickup (CLPU), a common occurrence in buildings with thermostatically controlled loads (TCLs), generates a significant peak power demand when loads restart. With widespread TCLs distribution, the restoration speed and power level could be impacted by the conventional grid restoration scheme due to limited distribution generator (DG) capability and power supply paths. In this context, this paper proposes a two-stage coordinated restoration scheme based on the novel hybrid AC/DC distribution grid, encompassing the grid configuration level, information interaction level, and designed restoration flow. The typical delayed exponential model is used to characterize CLPU properties during extended outages. In the 1st stage, the contained coordinated restoration strategy decides the optimal load restoration sequence with CLPU concerned. Then, the grid loss optimization is carried out in stage 2 to generate the proper power reference for DGs and voltage source converters (VSCs) of hybrid grids. In case studies, four types of heterogeneous buildings with varied CLPU characteristics are deployed in the analyzed grid. It is verified that the proposed scheme could make effective aggregation and dispatching for multiple DGs, achieving an additional 11.3 h of total load support, a 16.5 % increase of DG utilization and an 11.7 % enhancement of the resilience index compared to the conventional restoration scheme. Furthermore, this scheme demonstrates adaptability for resilience improvement under varied temperatures and fault locations.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A Coordinated Restoration Method of Hybrid AC/DC Distribution Network for Resilience Enhancement
    Zhang, Lu
    Wang, Chen
    Liang, Jun
    Wu, Mingzhe
    Zhang, Bo
    Tang, Wei
    IEEE TRANSACTIONS ON SMART GRID, 2023, 14 (01) : 112 - 125
  • [2] Two-stage Optimal Dispatching of AC/DC Hybrid Active Distribution Systems Considering Network Flexibility
    Yi Su
    Jiashen Teh
    Journal of Modern Power Systems and Clean Energy, 2023, 11 (01) : 52 - 65
  • [3] Two-stage Optimal Dispatching of AC/DC Hybrid Active Distribution Systems Considering Network Flexibility
    Su, Yi
    Teh, Jiashen
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2023, 11 (01) : 52 - 65
  • [4] Resilience-Oriented Two-Stage Restoration Considering Coordinated Maintenance and Reconfiguration in Integrated Power Distribution and Heating Systems
    Wang, Ke
    Xue, Yixun
    Shahidehpour, Mohammad
    Chang, Xinyue
    Li, Zening
    Zhou, Yue
    Sun, Hongbin
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2025, 16 (01) : 124 - 137
  • [5] A Two-Stage Protection Scheme Based on Control and Protection Coordination for AC/DC Hybrid Distribution Network
    Qian, Zhonghao
    Yuan, Yubo
    Li, Juan
    Dong, Hao
    Qin, Ting
    Huang, Xuan
    Lyu, Pengpeng
    Jiang, Yunlong
    Wang, Jiaming
    IEEE ACCESS, 2024, 12 : 132533 - 132542
  • [6] Restoration Strategy for Active Distribution Systems Considering Endogenous Uncertainty in Cold Load Pickup
    Li, Yujia Lauren
    Sun, Wei
    Yin, Wenqian
    Lei, Shunbo
    Hou, Yunhe
    IEEE TRANSACTIONS ON SMART GRID, 2022, 13 (04) : 2690 - 2702
  • [7] A Two-stage Reactive Power Optimization Strategy for AC/DC Hybrid Distribution Network
    Li, Chao
    Miao, Shihong
    Zhang, Di
    Li, Lixing
    2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 426 - 431
  • [8] Dynamic Restoration of Active Distribution Networks by Coordinated Repair Crew Dispatch and Cold Load Pickup
    Pang, Kaiyuan
    Wang, Chongyu
    Hatziargyriou, Nikos D.
    Wen, Fushuan
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2024, 39 (02) : 4699 - 4713
  • [9] Two-Stage Stochastic Programming Scheduling Model for Hybrid AC/DC Distribution Network Considering Converters and Energy Storage System
    Kang, Peng
    Guo, Wei
    Huang, Weigang
    Qiu, Zejing
    Yu, Meng
    Zheng, Feng
    Zhang, Yachao
    APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [10] Study on two-stage optimal scheduling of DC distribution networks considering flexible load response
    Chen, Lei
    Yang, Man
    Jiang, Yuqi
    Zheng, Shencong
    Li, Yifei
    You, Xiaoyan
    Chen, Hongkun
    IET ELECTRIC POWER APPLICATIONS, 2024, 18 (11) : 1690 - 1701