Experiments of high temperature inert gas plasma MHD electrical power generation with hall and diagonal connections

被引:0
作者
Komatsu, Fumihiko [1 ]
Tanaka, Manabu [1 ]
Murakami, Tomoyuki [1 ]
Okuno, Yoshihiro [1 ]
机构
[1] Department of Energy Sciences, Tokyo Insititute of Technology, Midoriku-ku, Yokohama 226-8502, 4259-G3-38, Nagatsuta-cho
来源
Komatsu, F. (komatsu.f.aa@m.titech.ac.jp) | 1600年 / Institute of Electrical Engineers of Japan卷 / 134期
基金
日本学术振兴会;
关键词
Diagonal connection; Hall connection; High temperature inert gas plasma; Linear shaped generator; MHD power generation;
D O I
10.1541/ieejpes.134.620
中图分类号
学科分类号
摘要
High temperature inert gas (argon) plasma MHD electrical power generation using a linear shaped channel with Hall and diagonal connections has been conducted. It is revealed from the observation by using a high-speed camera that the MHD power-generating plasma is almost stable regardless of the connection type. Enthalpy extraction ratios of 5.6% for the Hall connection, 6.7% for the diagonal connection (diagonal angle 53∼66 degree), and 10.1% for the diagonal connection (diagonal angle 36∼48 degree) have been achieved under the operating conditions of an inlet total temperature of 9000 K, an inlet total pressure of 0.105MPa, and a magnetic flux density of 4.0 T. The output power can suffer from a low electric field in the upstream region in a Hall connection, and is improved for no Hall current condition in a diagonal connection. © 2014 The Institute of Electrical Engineers of Japan.