Coordinated control strategies for DC fault ride-through of wind power integration via bipolar hybrid MMC-HVDC overhead lines

被引:0
作者
Li G. [1 ]
Zhang L. [1 ]
Jiang S. [1 ]
Xin Y. [1 ]
机构
[1] Key Laboratory of Modern Power System Simulation and Control & Renewable Energy Technology, Ministry of Education (Northeast Electric Power University), Jilin
来源
Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control | 2021年 / 49卷 / 10期
关键词
Bipolar MMC-HVDC; Coordinated control strategy; DC fault ride-through; Wind power integration; Zero DC voltage control;
D O I
10.19783/j.cnki.pspc.200880
中图分类号
学科分类号
摘要
The overhead line MMC-HVDC is an effective method for large-scale wind-power-friendly grid connection and reliable delivery. Faced with the high failure rate of overhead lines, a scheme of adopting symmetrical bipolar wiring and hybrid MMC with fault blocking capability is one of the main methods of tackling this. Based on this scheme, this paper proposes a DC fault ride-through coordinated control strategy for grid-connected wind power via a bipolar hybrid MMC-HVDC. Through hybrid MMC zero DC voltage control, the fault current is effectively blocked and the support ability of the fault pole MMC to the AC voltage is maintained. Based on the flexible operation mode of the symmetrical bipolar wiring scheme, and according to whether the fault pole power can be completely absorbed by non-fault poles, the control strategies of non-fault pole under self-absorption and non-self-absorption conditions and parameter adjustment principles are designed. Based on the frequency response capability of the wind farm, a control strategy without communication is designed to achieve accurate load reduction of wind power, and then achieve full load operation of a non-faulty MMC. This scheme could reduce the impact on the receiving AC system while maintaining the safe and stable operation of the system. Finally, a grid-connected system model is built on Matlab/Simulink to verify the effectiveness of the proposed DC fault ride-through coordinated control strategy. © 2021 Power System Protection and Control Press.
引用
收藏
页码:27 / 36
页数:9
相关论文
共 25 条
  • [21] CAO Shuai, XIANG Wang, YAO Liangzhong, Et al., AC and DC fault ride-through strategies for wind power integration via hybrid MMC-HVDC, Automation of Electric Power Systems, 42, 7, pp. 37-43, (2018)
  • [22] CAO Shuai, XIANG Wang, LIN Weixing, Et al., Fault ride-through and energy dissipation control of bipolar hybrid MMC-MTDC integrating wind farms, Power System Protection and Control, 47, 7, pp. 39-48, (2019)
  • [23] XU Jin, JIN Yi, HU Congchuan, Et al., DC voltage adaptive droop control of multi-terminal VSC-HVDC system for offshore wind farms integration, Power System Protection and Control, 46, 4, pp. 78-85, (2018)
  • [24] CUI S, SUL S K., A Comprehensive DC short-circuit fault ride through strategy of hybrid modular multilevel converters (MMCs) for overhead line transmission, IEEE Transactions on Power Electronics, 31, 11, pp. 7780-7796, (2016)
  • [25] YAN Xiangwu, CUI Sen, SONG Zijun, Et al., Inertia and primary frequency modulation strategy of doubly-fed wind turbine based on super-capacitor energy storage control, Automation of Electric Power Systems, 44, 14, pp. 111-129, (2020)