Mass attenuation coefficients of human body Organs using MCNPX Monte Carlo Code

被引:0
作者
Tekin H.O. [1 ,4 ]
Singh V.P. [2 ]
Altunsoy E.E. [3 ,4 ]
Manici T. [4 ]
Sayyed M.I. [5 ]
机构
[1] Department of Radiotherapy, Vocational School of Health Services, Uskudar University, Istanbul
[2] Department of Physics, Faculity of Science, Karnatak University, Dharwad
[3] Department of Medical Imaging, Vocational School of Health Services, Uskudar University, Istanbul
[4] Medical Radiation Research Center (USMERA), Uskudar University, Istanbul
[5] Department of Physics, Faculty of Science, University of Tabuk, Tabuk
关键词
Attenuation coefficient; MCNP-X; Monte Carlo;
D O I
10.22038/ijmp.2017.23478.1230
中图分类号
学科分类号
摘要
Introduction: Investigation of radiation interaction with living organs has always been a thrust area in medical and radiation physics. The investigated results are being used in medical physics for developing improved and sensitive techniques and minimizing radiation exposure. In this study, mass attenuation coefficients of different human organs and biological materials such as adipose, blood, bone, brain, eye lens, lung, muscle, skin, and tissue have been calculated. Materials and Methods: In the present study, Monte Carlo N-Particle eXtended (MCNP-X) version 2.4.0 was used for determining mass attenuation coefficients, and the obtained results were compared with earlier investigations (using GEometry ANd Tracking [GEANT4] and FLUKA computer simulation packages) for blood, bone, lung, eye lens, adipose, tissue, muscle, brain, and skin materials at different energies. Results: The results of this study showed that the obtained results from MCNP-X were in high accordance with the National Institute of Standards and Technology data. Conclusion: Our findings would be beneficial for use of present simulation technique and mass attenuation coefficients for medical and radiation physics applications.
引用
收藏
页码:229 / 240
页数:11
相关论文
共 50 条
  • [31] Prediction of 89Zr production using the Monte Carlo code FLUKA
    Infantino, A.
    Cicoria, G.
    Pancaldi, D.
    Ciarmatori, A.
    Boschi, S.
    Fanti, S.
    Marengo, M.
    Mostacci, D.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (08) : 1134 - 1137
  • [32] Computer Code for Materials Diagnosis Using Monte Carlo Method and Neural Networks
    Bendjama H.
    Mahdi D.
    Journal of Failure Analysis and Prevention, 2016, 16 (5) : 931 - 937
  • [33] Evaluation of fast neutron induced single event upset in a static random access memory and simulation by Monte Carlo N-Particle Code (MCNPX)
    Arita, Y
    Takai, M
    Ogawa, I
    Kishimoto, T
    Nagai, Y
    Hatanaka, K
    Matsuoka, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2004, 43 (6B): : L797 - L799
  • [34] Assessment of the effectiveness of attenuation of Pb aprons by using TLD dosimetry and Monte Carlo calculations
    Olaya Davila, H.
    Diaz Merchan, J. A.
    Vega Carrillo, H. R.
    Martinez Ovalle, S. A.
    APPLIED RADIATION AND ISOTOPES, 2018, 138 : 56 - 59
  • [35] Modeling of realistic pebble bed reactor geometries using the Serpent Monte Carlo code
    Rintala, Ville
    Suikkanen, Heikki
    Leppanen, Jaakko
    Kyrki-Rajamaki, Riitta
    ANNALS OF NUCLEAR ENERGY, 2015, 77 : 223 - 230
  • [36] Cellular dosimetry calculations for Strontium-90 using Monte Carlo code PENELOPE
    Hocine, Nora
    Farlay, Delphine
    Boivin, Georges
    Franck, Didier
    Agarande, Michelle
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2014, 90 (11) : 953 - 958
  • [37] Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
    Sheikh-Bagheri, D
    Rogers, DWO
    MEDICAL PHYSICS, 2002, 29 (03) : 391 - 402
  • [38] Determination of gamma-ray transmission factors of WO3-TeO2-B2O3 glasses using MCNPX Monte Carlo code for shielding and protection purposes
    ALMisned, Ghada
    Baykal, Duygu Sen
    Susoy, Gulfem
    Kilic, Gokhan
    Zakaly, Hesham M. H.
    Ene, Antoaneta
    Tekin, Huseyin Ozan
    APPLIED RHEOLOGY, 2022, 32 (01) : 166 - 177
  • [39] Modelling diffractive X-ray scattering using the EGS Monte Carlo code
    O'Dwyer, J. N.
    Tickner, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) : 127 - 129
  • [40] Photon attenuation coefficients of different rock samples using MCNPX, Geant4 simulation codes and experimental results: a comparison study
    Obaid, Shamsan S.
    Sayyed, M. I.
    Gaikwad, D. K.
    Tekin, H. O.
    Elmahroug, Y.
    Pawar, P. P.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2018, 173 (11-12): : 900 - 914