Mass attenuation coefficients of human body Organs using MCNPX Monte Carlo Code

被引:0
作者
Tekin H.O. [1 ,4 ]
Singh V.P. [2 ]
Altunsoy E.E. [3 ,4 ]
Manici T. [4 ]
Sayyed M.I. [5 ]
机构
[1] Department of Radiotherapy, Vocational School of Health Services, Uskudar University, Istanbul
[2] Department of Physics, Faculity of Science, Karnatak University, Dharwad
[3] Department of Medical Imaging, Vocational School of Health Services, Uskudar University, Istanbul
[4] Medical Radiation Research Center (USMERA), Uskudar University, Istanbul
[5] Department of Physics, Faculty of Science, University of Tabuk, Tabuk
关键词
Attenuation coefficient; MCNP-X; Monte Carlo;
D O I
10.22038/ijmp.2017.23478.1230
中图分类号
学科分类号
摘要
Introduction: Investigation of radiation interaction with living organs has always been a thrust area in medical and radiation physics. The investigated results are being used in medical physics for developing improved and sensitive techniques and minimizing radiation exposure. In this study, mass attenuation coefficients of different human organs and biological materials such as adipose, blood, bone, brain, eye lens, lung, muscle, skin, and tissue have been calculated. Materials and Methods: In the present study, Monte Carlo N-Particle eXtended (MCNP-X) version 2.4.0 was used for determining mass attenuation coefficients, and the obtained results were compared with earlier investigations (using GEometry ANd Tracking [GEANT4] and FLUKA computer simulation packages) for blood, bone, lung, eye lens, adipose, tissue, muscle, brain, and skin materials at different energies. Results: The results of this study showed that the obtained results from MCNP-X were in high accordance with the National Institute of Standards and Technology data. Conclusion: Our findings would be beneficial for use of present simulation technique and mass attenuation coefficients for medical and radiation physics applications.
引用
收藏
页码:229 / 240
页数:11
相关论文
共 50 条
  • [21] Effects of micro-sized and nano-sized WO3 on mass attenauation coefficients of concrete by using MCNPX code
    Tekin, H. O.
    Singh, V. P.
    Manici, T.
    APPLIED RADIATION AND ISOTOPES, 2017, 121 : 122 - 125
  • [22] Gamma-Ray Attenuation Properties of Boron Carbide in Radiological Energy Range Using MCNPX Code
    Tekin, H. O.
    Altunsoy, E. E.
    Ozturk, F. C.
    Kilicoglu, O.
    Sayyed, M. I.
    TURKISH PHYSICAL SOCIETY 34TH INTERNATIONAL PHYSICS CONGRESS (TPS34), 2018, 2042
  • [23] X-ray fluorescence Kα/Kβ ratios for a layered specimen: Comparison of measurements and Monte Carlo calculations with the MCNPX code
    Trojek, T.
    Wegrzynek, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3) : 311 - 315
  • [24] Monte Carlo simulation and practical investigation of body organs activation by Am–Be neutron source
    Ali Nouraddini-Shahabadi
    Mohammad Reza Rezaie
    Yassin Hiedarizadeh
    Saeed Mohammadi
    Journal of the Korean Physical Society, 2024, 84 : 672 - 680
  • [25] Responses of a 6LiI Bonner Sphere Spectrometer using the Monte Carlo codes PHITS and MCNPX
    Oliveira, Rafael Santos
    da Silva, Juliana Batista
    Mendes, Lucas Moacir Machado
    Lacerda, Marco Aurelio de Sousa
    APPLIED RADIATION AND ISOTOPES, 2023, 200
  • [26] A review of radiation dosimetry applications using the MCNP Monte Carlo code
    Solberg, TD
    DeMarco, JJ
    Chetty, IJ
    Mesa, AV
    Cagnon, CH
    Li, AN
    Mather, KK
    Medin, PM
    Arellano, AR
    Smathers, JB
    RADIOCHIMICA ACTA, 2001, 89 (4-5) : 337 - 355
  • [27] Monte Carlo simulation and practical investigation of body organs activation by Am-Be neutron source
    Nouraddini-Shahabadi, Ali
    Rezaie, Mohammad Reza
    Hiedarizadeh, Yassin
    Mohammadi, Saeed
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 84 (09) : 672 - 680
  • [28] Attenuation Coefficients of Soy-Lignin Bonded Rhizophora spp. Particleboard as a Potential Phantom Material Using Monte Carlo GATE
    Zuber, Siti Hajar
    Hadi, Muhammad Fahmi Rizal Abdul
    Hashikin, Nurul Ab. Aziz
    Yusof, Mohd Fahmi Mohd
    Aziz, Mohd Zahri Abdul
    BIORESOURCES, 2024, 19 (04): : 8920 - 8934
  • [29] Modeling energy deposition in trabecular spongiosa using the Monte Carlo code Penelope
    Gersh, Jacob A.
    Dingfelder, Michael
    Toburen, Larry H.
    HEALTH PHYSICS, 2007, 93 (01): : 47 - 59
  • [30] Validation of UNIST Monte Carlo code MCS using VERA progression problems
    Tung Dong Cao Nguyen
    Lee, Hyunsuk
    Choi, Sooyoung
    Lee, Deokjung
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (05) : 878 - 888