Mass attenuation coefficients of human body Organs using MCNPX Monte Carlo Code

被引:0
作者
Tekin H.O. [1 ,4 ]
Singh V.P. [2 ]
Altunsoy E.E. [3 ,4 ]
Manici T. [4 ]
Sayyed M.I. [5 ]
机构
[1] Department of Radiotherapy, Vocational School of Health Services, Uskudar University, Istanbul
[2] Department of Physics, Faculity of Science, Karnatak University, Dharwad
[3] Department of Medical Imaging, Vocational School of Health Services, Uskudar University, Istanbul
[4] Medical Radiation Research Center (USMERA), Uskudar University, Istanbul
[5] Department of Physics, Faculty of Science, University of Tabuk, Tabuk
关键词
Attenuation coefficient; MCNP-X; Monte Carlo;
D O I
10.22038/ijmp.2017.23478.1230
中图分类号
学科分类号
摘要
Introduction: Investigation of radiation interaction with living organs has always been a thrust area in medical and radiation physics. The investigated results are being used in medical physics for developing improved and sensitive techniques and minimizing radiation exposure. In this study, mass attenuation coefficients of different human organs and biological materials such as adipose, blood, bone, brain, eye lens, lung, muscle, skin, and tissue have been calculated. Materials and Methods: In the present study, Monte Carlo N-Particle eXtended (MCNP-X) version 2.4.0 was used for determining mass attenuation coefficients, and the obtained results were compared with earlier investigations (using GEometry ANd Tracking [GEANT4] and FLUKA computer simulation packages) for blood, bone, lung, eye lens, adipose, tissue, muscle, brain, and skin materials at different energies. Results: The results of this study showed that the obtained results from MCNP-X were in high accordance with the National Institute of Standards and Technology data. Conclusion: Our findings would be beneficial for use of present simulation technique and mass attenuation coefficients for medical and radiation physics applications.
引用
收藏
页码:229 / 240
页数:11
相关论文
共 50 条
  • [1] The MCNPX Monte Carlo radiation transport code
    Waters, Laurie S.
    McKinney, Gregg W.
    Durkee, Joe W.
    Fensin, Michael L.
    Hendricks, John S.
    James, Michael R.
    Johns, Russell C.
    Pelowitz, Denise B.
    HADRONIC SHOWER SIMULATION WORKSHOP, 2007, 896 : 81 - +
  • [2] SHIELDING PROPERTIES AND EFFECTS OF WO3 AND PbO ON MASS ATTENUATION COEFFICIENTS BY USING MCNPX CODE
    Tekin, H. O.
    Sayyed, M. I.
    Altunsoy, E. E.
    Manici, T.
    DIGEST JOURNAL OF NANOMATERIALS AND BIOSTRUCTURES, 2017, 12 (03) : 861 - 867
  • [3] Methodology for digital radiography simulation using the Monte Carlo code MCNPX for industrial applications
    Souza, E. M.
    Correa, S. C. A.
    Silva, A. X.
    Lopes, R. T.
    Oliveira, D. F.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (05) : 587 - 592
  • [4] Monte Carlo calculations for gamma-ray mass attenuation coefficients of some soil samples
    Tarim, U. Akar
    Gurler, O.
    Ozmutlu, E. N.
    Yalcin, S.
    ANNALS OF NUCLEAR ENERGY, 2013, 58 : 198 - 201
  • [5] Calculation of gamma-ray mass attenuation coefficients of some Egyptian soil samples using Monte Carlo methods
    Medhat, M. E.
    Demir, Nilgun
    Tarim, Urkiye Akar
    Gurler, Orhan
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (08): : 706 - 714
  • [6] Assessment of secondary particles in breast proton therapy by Monte Carlo simulation code using MCNPX
    Maroufkhani, F.
    Abtahi, S. M. M.
    Kakavand, T.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (01): : 23 - 29
  • [7] Spread-out Bragg peak and monitor units calculation with the Monte Carlo code MCNPX
    Herault, J.
    Iborra, N.
    Serrano, B.
    Chauvel, P.
    MEDICAL PHYSICS, 2007, 34 (02) : 680 - 688
  • [8] Application of the MCNPX Monte Carlo Code for Studying the ADS Spallation Target Parameters
    Gomaa, I. M.
    Amin, E. A.
    Bashter, I. I.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2016, 49 (02): : 68 - 73
  • [9] A fast Monte Carlo code for proton transport in radiation therapy based on MCNPX
    Jabbari, Keyvan
    Seuntjens, Jan
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (03) : 156 - 163
  • [10] Monte Carlo Simulation of the Dose Rate Distribution of a Moroccan Panoramic Gamma Irradiator Using the MCNPX Code
    A. Aknouch
    M. Mouhib
    R. Sebihi
    A. Didi
    Y. El-ouardi
    A. Boubekraoui
    A. Choukri
    Moscow University Physics Bulletin, 2020, 75 : 35 - 38