A Self-Healing Magnetic-Array-Type Current Sensor With Data-Driven Identification of Abnormal Magnetic Measurement Units

被引:0
|
作者
Liu, Xiaohu [1 ]
Ma, Kang [1 ]
Liu, Jian [1 ]
Zhao, Wei [1 ,2 ]
Peng, Lisha [1 ]
Huang, Songling [1 ]
Li, Shisong [1 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Yangtze Delta Reg Inst, Jiaxing 314006, Zhejiang, Peoples R China
关键词
Current measurement; Magnetic field measurement; Measurement errors; Measurement uncertainty; Magnetic fields; Accuracy; Frequency measurement; Conductors; Magnetometers; Correlation; Cyber-physical correlation; drift in measurement error; magnetic-array-type current sensor; principal component analysis (PCA);
D O I
10.1109/TIM.2024.3470055
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic-array-type current sensors have garnered increasing popularity owing to their notable advantages, including broadband functionality, a large dynamic range, cost-effectiveness, and compact dimensions. However, the susceptibility of the measurement error of one or more magnetic measurement units (MMUs) in the current sensor to drift significantly from the nominal value due to environmental factors poses a potential threat to the measurement accuracy of the current sensor. In light of the need to ensure sustained measurement accuracy over the long term, this article proposes an innovative self-healing approach rooted in cyber-physical correlation. This approach aims to identify MMUs exhibiting abnormal measurement errors, allowing for the exclusive utilization of the remaining unaffected MMUs in the current measurement process. To achieve this, principal component analysis (PCA) is employed to discern the primary component, arising from fluctuations of the measured current, from the residual component, attributed to the drift in measurement error. This analysis is conducted by scrutinizing the measured data obtained from the MMUs. Subsequently, the squared prediction error (SPE) statistic (also called Q statistic) is deployed to individually identify any MMU displaying abnormal behavior. The experimental results demonstrate the successful online identification of abnormal MMUs without the need for a standard magnetic field sensor. By eliminating the contributions from the identified abnormal MMUs, the accuracy of the current measurement is effectively preserved.
引用
收藏
页数:12
相关论文
共 10 条
  • [1] Processing magnetic sensor array data for AC current measurement in multiconductor systems
    D'Antona, G
    Di Rienzo, L
    Ottoboni, R
    Manara, A
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (05) : 1289 - 1295
  • [2] Research Progress of Current Measurement Method Based on Magnetic Sensor Array
    Hu J.
    Ma H.
    Li P.
    Tian B.
    Liu Z.
    Lü Q.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (05): : 1779 - 1794
  • [3] A Novel Adaptive Filter for Accurate Measurement of Current with Magnetic Sensor Array
    Chen, Yafeng
    Huang, Qi
    Khawaja, Arsalan Habib
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [4] Interference-rejecting current measurement method with tunnel magnetoresistive magnetic sensor array
    Chen, Yafeng
    Huang, Qi
    Khawaja, Arsalan Habib
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2018, 12 (06) : 733 - 738
  • [5] A novel non-invasion magnetic sensor array based measurement method of large current
    Chen, Yafeng
    Huang, Qi
    Khawaja, Arsalan Habib
    Cai, Dongsheng
    Wu, Jie
    MEASUREMENT, 2019, 139 : 78 - 84
  • [6] A Flexible Alternating Current Field Measurement Magnetic Sensor Array for In Situ Inspection of Cracks in Underwater Structure
    Yuan, Xin'an
    Wang, Han
    Li, Wei
    Yin, Xiaokang
    Zhang, Xihe
    Ding, Jianxing
    Zhao, Jianchao
    Chen, Qinyu
    Wu, Jun
    Li, Xiao
    Hu, Dong
    Gao, Yu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 10
  • [7] An Interference-Rejection Strategy for Measurement of Small Current Under Strong Interference With Magnetic Sensor Array
    Chen, Yafeng
    Huang, Qi
    Khawaja, Arsalan Habib
    IEEE SENSORS JOURNAL, 2019, 19 (02) : 692 - 700
  • [8] Magnetic Sensor Array-Based AC current Measurement for Multiconductor Cables Using Evolutionary Computation Method
    Meng, Lichan
    Gao, Pengfei
    Haji, Moosa Moghimi
    Xu, Wilsun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (10) : 2747 - 2758
  • [9] ADAPTIVE FILTERING-BASED CURRENT RECONSTRUCTION IN NON-CONTACT MAGNETIC SENSOR ARRAY MEASUREMENT SYSTEM
    Chen, Yafeng
    Huang, Qi
    METROLOGY AND MEASUREMENT SYSTEMS, 2019, 26 (04) : 697 - 711
  • [10] Deep learning-based target metabolite isolation and big data-driven measurement uncertainty estimation in proton magnetic resonance spectroscopy of the brain
    Lee, Hyeong Hun
    Kim, Hyeonjin
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (04) : 1689 - 1706