Efficiency analysis for water turbine generator of agricultural reservoir

被引:0
作者
Kim, Jong-Gyeum [1 ]
机构
[1] Dept. of Electrical Engineering, Gangneung-wonju National University
关键词
Active power; Efficiency; Induction generator; Renewable energy; Reservoir; Water turbine;
D O I
10.5370/KIEE.2013.62.9.1223
中图分类号
学科分类号
摘要
If the factory test efficiency and field operation efficiency of water turbine are different from each other, issues for efficiency warranty can be raised. So, This paper shows the result for comparative analysis of field operating efficiency vs plant testing efficiency of the water turbine generator installed in agricultural reservoir. The efficiency of the induction generator is analyzed by the change of rotational speed with the parameter obtained by test, the efficiency of water turbine is calculated by the change of head with the design flow. Efficiency deviation of induction generator is lower but the variation of developed power is pretty high near the rated speed and the efficiency variation of water turbine is high by the fluctuation of head for constant flow. It was found that factory test efficiency and total efficiency of water turbine generator calculated according to the rotational speed are very close.
引用
收藏
页码:1223 / 1227
页数:4
相关论文
共 10 条
  • [1] Lee G.-B., Et al., Activation strategy of hydropower development as new & renewable energy, KIEE Summer Annual conference, 7, pp. 1231-1232, (2010)
  • [2] 2012 New and Renewable Energy, (2013)
  • [3] Kim J.-G., Output characterization analysis of Induction generator using test data, KIEE, 62, 7, pp. 1027-1032, (2013)
  • [4] Young-Kuk K., Kim J.-G., A study on the operation characteristic of induction generator in the small hydropower plant, KIEE, 62, 5, pp. 632-638, (2013)
  • [5] Pankaj K.S., Nelson J.P., Application guidelines for induction generators, Proc. International Conference on Electrical Machines and Drives, MAY, pp. 18-21, (1997)
  • [6] Godoy Simoes M., Farret F.A., Renewable Energy Systems-design And Analysis With Induction Generators, (2004)
  • [7] Kim J.-G., Characteristics analysis of 3-phase induction generator at the unbalanced load operation, KIEE, 56, 3, pp. 123-128, (2007)
  • [8] Kim J.-G., Park Y.-J., Kim I.-J., Kim Y.-K., Characteristics analysis of induction generator with a change in rotor speed, KIEE, 60, 12, pp. 2225-2229, (2011)
  • [9] Fritz J.J., Small and Mini Hydropower Systems, (1984)
  • [10] Standard Test Procedure for Polyphase Induction Motors and Generators