Development the device of automatic dispensing low flowrates of aggressive and radioactive liquids

被引:0
作者
Pletnev A.O. [1 ]
Denisevich A.A. [1 ]
Goryunov A.G. [1 ]
Manenti F. [2 ]
机构
[1] National Research Tomsk Polytechnic University, School of Nuclear Science and Engineering, Lenina avenue, 30, Tomsk
[2] Politecnico di Milano, Dept. di Chimica, Materiali e Ingegneria Chimica Giulio Natta, Piazza Leonardo da Vinci 32, Milano
来源
Chemical Engineering Transactions | 2018年 / 70卷
关键词
D O I
10.3303/CET1870236
中图分类号
学科分类号
摘要
Currently, the problem of accurate metering micro-flows (up to 100 ml / min) liquid components of technological processes is acute in the chemical and nuclear industries. This problem is due to the fact that peristaltic pumps are used for batching, in which the slope of the flowrate characteristic changes with time. This is due to the wear of the flexible hose due to numerous compression cycles. Using of peristaltic pumps is due to the fact that in most technological processes in the nuclear and chemical industries, aggressive reagents are used and the use of other types of pumps is problematic because of the need to contact the moving parts of pumps directly with the environment. This work describes the developed flowrate sensor, which is a capillary flowmeter, a measured volumetric flowrate. Metrological and production tests of the developed flowmeter are conducted and described. The variants of realization of the device of the automatic dispensing of low flowrate of aggressive and radioactive liquids. Copyright © 2018, AIDIC Servizi S.r.l.
引用
收藏
页码:1411 / 1416
页数:5
相关论文
共 10 条
  • [1] Adamov E.O., Rachkov V.I., New technological platform for the national nuclear energy strategy development, Thermal Engineering, 64, pp. 945-951, (2017)
  • [2] Barbe J., Boineau F., Mace T., Otal P., Development of a gas micro-flow transfer standard, Flow Measurement and Instrumentation, 44, pp. 43-50, (2015)
  • [3] Farzaneh-Gord M., Parvizi S., Arabkoohsar A., Machado L., Koury R.N.N., Potential use of capillary tube thermal mass flow meters to measure residential natural gas consumption, Journal of Natural Gas Science and Engineering, 22, pp. 540-550, (2015)
  • [4] Feng S., Bi Q., Liu Z., Pan H., Cao D., Viscosity Measurement of Aviation Kerosene RP-3 Using a Double-Capillary Viscometer with Equal Mass Flow, Hsi-An Chiao Tung Ta Hsueh/Journal of xi'An Jiaotong University, 51, pp. 48-53, (2017)
  • [5] Kulikov G.G., Apse V.A., Closed fuel cycle with increased fuel burn-up and economy applying of thorium resources, Journal of Physics: Conference Series, 781, (2017)
  • [6] Ochoa Bique A.O., Goryunov A.G., Manenti F., Optimization of uranium crystallization process by using MPC approach, Chemical Engineering Transactions, 52, pp. 331-336, (2016)
  • [7] Parvizi S., Arabkoohsar A., Farzaneh-Gord M., Natural gas compositions variation effect on capillary tube thermal mass flow meter performance, Flow Measurement and Instrumentation, 50, pp. 229-236, (2016)
  • [8] Shadrin A.Y., Ivanov V.B., Skupov M.V., Troyanov V.M., Zherebtsov A.A., Comparison of closed nuclear fuel cycle technologies, Atomic Energy, 121, pp. 119-126, (2016)
  • [9] Troyanov V.M., Grachev A.F., Zabud'Ko L.M., Skupov M.V., Prospects for using nitride fuel in fast reactors with a closed nuclear fuel cycle, Atomic Energy, 117, pp. 85-91, (2014)
  • [10] Vilnina A.V., Efremov E.V., Pletnev A.O., Chursin Y.A., Barkov D.E., Kabrysheva O.P., Automatic control system of the evaporator in the technology of spent nuclear fuel processing, Chemical Engineering Transactions, 61, pp. 1441-1446, (2017)