Reliability Analysis of Axial Compressive Strength of Concrete-Filled Steel Tube (CFST) under Coupled Corrosion and Load Effects
被引:1
作者:
Ma, Dan-Yang
[1
,2
]
Ma, Shuai
[1
]
Xu, Li-Yan
[1
,2
]
机构:
[1] Beihang Univ, Sch Transportat Sci & Engn, Beijing 100191, Peoples R China
[2] Minist Educ, Key Lab Intelligent Transportat Technol & Syst, Beijing 100191, Peoples R China
来源:
基金:
中国国家自然科学基金;
国家重点研发计划;
关键词:
concrete-filled steel tube;
parametric modelling;
stochastic-based modelling;
axial compressive strength;
reliability index;
BEHAVIOR;
COLUMNS;
D O I:
10.3390/buildings14103205
中图分类号:
TU [建筑科学];
学科分类号:
0813 ;
摘要:
This paper presents a finite element analysis (FEA) of and reliability study on concrete-filled steel tube (CFST) members under the combined effects of corrosion and compressive loading. First, a stochastic-based FE model is established through the proposed secondary development program based on ABAQUS 2021 software. The model could account for the uncertainties of material, geometric, and corrosion effect on CFST members. The reliability of the built model was validated through experimental data of corroded CFST members under compression loading. Subsequently, the compressive performance of CFST under a combination of corrosion and loading was further investigated by numerical parameter analysis. A total of 1800 models were created to clarify the coupling mechanism among the core concrete strength, the steel tube strength, the steel ratio, and the maximum strength of the CFST member. Three theoretical formulas presented in classical design standards were used to calculate the axial compressive strength of the corroded CFST, and the uncertainty parameters mu kp and delta kp were also obtained for the discussed design formulas. Finally, the First Order and Second Moment (FOSM) method was employed to estimate the reliability indices beta across different standards. The calculations revealed that the reliability indices beta according to European standard ranges from 2.93 to 5.52, with some results falling below the target reliability index beta T of 3.65. In addition, the multi-parameter coupling effects on reliability index beta were investigated, and the main influencing factors were obtained. By leveraging the reliability analysis, reasonable design requirements can be proposed for CFST members under the coupling effects of corrosion and external load, which provides a design basis for the CFST member.
引用
收藏
页数:18
相关论文