Design on the primary side of active optic-electric current transformer based on the Rogowski coil

被引:0
|
作者
Yang, Guang
Liu, Xin-Rong
Liu, Xi-Tao
机构
[1] Inst. of Opt-electronic Info. Tech., Yantai Univ., Yantai 264005, China
[2] Sch. of Info. and Electron. Eng., Inst. of business and Technol. Univ., Yantai 264005, China
[3] Sch. of Electrical Eng., Hehai Univ., Nanjing 210098, China
来源
Gaoya Dianqi/High Voltage Apparatus | 2005年 / 41卷 / 01期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, a principle of design of primary side of active optic-electric current transducer is studied and discussed. By improving the integrator circuits, low-frequency disturbance is eliminated and phase compensation is realized, too. As for the problem of the power supply to the primary side, a new design, which combines the advantages of two methods by the aid of CT and PT respectively, is presented. In order to avoid the problem that the device can't work normally when the main current is either too low or too high, a feedback adjusting circuit and a backup circuit is designed. It is proved by experiments that this design is feasible.
引用
收藏
页码:45 / 47
相关论文
共 50 条
  • [21] Development of the Test Platform for the Characteristics of the Rogowski Coil Electronic Current Transformer
    Chen, Yu
    Huang, Qi
    Jing, Shi
    Mo, Chenggui
    Zhen, Wei
    Wu, Jie
    2016 INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE), 2016, : 278 - 283
  • [22] Heavy current measurement based on Rogowski coil
    Dai, Jianhua
    Li, Kaicheng
    Gaodianya Jishu/High Voltage Engineering, 2002, 28 (01):
  • [23] Study on a new type optic-electric transformer - art. no. 615037
    Li, WK
    Zheng, SX
    2nd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, Pts 1 and 2, 2006, 6150 : 15037 - 15037
  • [24] Rogowski Coil with an Active Integrator for Measurement of Switching Impulse Current
    Limcharoen, Worrakan
    Yutthagowith, Peerawut
    2013 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2013,
  • [25] Research about Measurement Performance of Optic-Electric DC Current Transformer in 500kV HVDC Power System
    Han, Xiaotao
    Xu, Yan
    Fu, Chuang
    Rao, Hong
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3431 - +
  • [26] Utilizing Rogowski Coil for Saturation Detection and Compensation in Iron Core Current Transformer
    Bagheri, Alireza
    Allahbakhshi, Mahdi
    Behi, Donya
    Tajdinian, Mohsen
    2017 25TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2017, : 1066 - 1071
  • [27] Design and Construction of a Rogowski Coil for Measuring Wide Pulsed Current
    Liu, Yi
    Lin, Fuchang
    Zhang, Qin
    Zhong, Heqing
    IEEE SENSORS JOURNAL, 2011, 11 (01) : 123 - 130
  • [28] Design of a Current Measurement System in a Plasma Thruster with Rogowski Coil
    De Alessandro, R. O.
    Velez Ibarra, M. D.
    Brito, H. H.
    IEEE LATIN AMERICA TRANSACTIONS, 2013, 11 (01) : 119 - 125
  • [29] Research and design of digital integrator based on Rogowski coil
    Wang, X. (renzhe002@163.com), 2013, Electric Power Automation Equipment Press (33):
  • [30] Distance Relay Based on Rogowski Coil Current Transformer by Using Instantaneous Value after Equal Transfer Processes
    Li B.
    Shi X.
    Wang Z.
    Wen M.
    Zhang X.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (05): : 1353 - 1362