Performance of the detection system for X-ray pulsar based navigation

被引:5
作者
Sheng, Li-Zhi [1 ,2 ]
Zhao, Bao-Sheng [1 ]
Zhou, Feng [1 ]
Wang, Peng [1 ]
Song, Juan [1 ,2 ]
Liu, Yong-An [1 ]
Shen, Jing-Shi [3 ]
Hu, Hui-Jun [3 ]
Ma, Xiao-Fei [1 ,2 ]
机构
[1] State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences
[2] University of Chinese Academy of Sciences
[3] Shandong Aerospace Electro-Technology Institute, Yantai
来源
Zhao, B.-S. (open@opt.ac.cn) | 2013年 / Chinese Optical Society卷 / 42期
关键词
Micro-Channel Plate(MCP) detector; Minimum detectable power; Signal-to-Noise Ratio(SNR); Single photon detection; X-ray pulsar navigation;
D O I
10.3788/gzxb20134209.1071
中图分类号
学科分类号
摘要
In order to assess the performance of detection system for X-ray pulsar navigation, the expression of the signal-to-noise ratio (SNR) and the minimum detectable power are derived in the photon counting mode of the system. Experiment system to measure the SNR and the minimum detectable power is setup. The minimum detectable power is measured; the SNRs at different integration time, optical power and threshold voltage are calculated. The X-ray pulse profile is reconstructed by measuring the time of arrival (TOA) of the X-ray photons. Experimental results show that the SNR of the pulse profile is improved and the curve of the pulse profile tends to smooth with the increasing of optical power and the integration time; the SNR is 26.3 and the pulse profile is optimal when the threshold voltage is -150 mV; the minimum detectable power of the system is 3.5×10-16 W.
引用
收藏
页码:1071 / 1076
页数:5
相关论文
共 50 条
[41]   Analysis of spectral blur effects in x-ray scatter imaging [J].
Leclair, RJ ;
Johns, PC .
MEDICAL PHYSICS, 1999, 26 (09) :1811-1816
[42]   A lesion detectability simulation method for digital x-ray imaging [J].
Cooper, VN ;
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 2000, 27 (01) :66-74
[43]   Theoretical and Technical Research of X-ray Communication in Plasma Sheath [J].
Su Tong ;
Sheng Lizhi ;
Liu Yongan ;
Zhang Xuehan ;
Liu Yifan ;
Zhao Baosheng .
ACTA PHOTONICA SINICA, 2021, 50 (11)
[44]   A semianalytic model to investigate the potential applications of x-ray scatter imaging [J].
Leclair, RJ ;
Johns, PC .
MEDICAL PHYSICS, 1998, 25 (06) :1008-1020
[45]   Optimum momentum transfer arguments for x-ray forward scatter imaging [J].
Leclair, RJ ;
Johns, PC .
MEDICAL PHYSICS, 2002, 29 (12) :2881-2890
[46]   X-ray forward-scatter imaging: Experimental validation of model [J].
Leclair, RJ ;
Johns, PC .
PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 :3074-3077
[47]   Progress in X-ray imaging and spectroscopy of ultraintense laser matter interactions [J].
Gizzi, L. A. ;
Koester, P. ;
Labate, L. ;
Levato, T. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (02) :836-841
[48]   Fundamental information content accessible with medical x-ray scatter imaging [J].
Leclair, RJ ;
Johns, PC .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :672-681
[49]   X-ray forward-scatter imaging: Experimental validation of model [J].
Leclair, RJ ;
Johns, PC .
MEDICAL PHYSICS, 2001, 28 (02) :210-219
[50]   Energy Window Optimization for X-Ray K-Edge Tomographic Imaging [J].
Meng, Bo ;
Cong, Wenxiang ;
Xi, Yan ;
De Man, Bruno ;
Wang, Ge .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (08) :1623-1630