Performance of the detection system for X-ray pulsar based navigation

被引:5
|
作者
Sheng, Li-Zhi [1 ,2 ]
Zhao, Bao-Sheng [1 ]
Zhou, Feng [1 ]
Wang, Peng [1 ]
Song, Juan [1 ,2 ]
Liu, Yong-An [1 ]
Shen, Jing-Shi [3 ]
Hu, Hui-Jun [3 ]
Ma, Xiao-Fei [1 ,2 ]
机构
[1] [1,Sheng, Li-Zhi
[2] Zhao, Bao-Sheng
[3] Zhou, Feng
[4] Wang, Peng
[5] 1,Song, Juan
[6] Liu, Yong-An
[7] Shen, Jing-Shi
[8] Hu, Hui-Jun
[9] 1,Ma, Xiao-Fei
来源
Zhao, B.-S. (open@opt.ac.cn) | 2013年 / Chinese Optical Society卷 / 42期
关键词
Signal to noise ratio;
D O I
10.3788/gzxb20134209.1071
中图分类号
学科分类号
摘要
引用
收藏
页码:1071 / 1076
相关论文
共 50 条
  • [1] A new method of evaluation of X-ray pulsar detector sensitivity
    Hu Hui-jun
    Song Juan
    Shao Si-pei
    Liu Jin-sheng
    Wang Wen-cong
    FIFTH SYMPOSIUM ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATION, 2019, 11023
  • [2] Quantification of signal detection performance degradation induced by phase-retrieval in propagation-based x-ray phase-contrast imaging
    Chou, Cheng-Ying
    Anastasio, Mark A.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [3] Performance analysis of LYSO-SiPM detection module for X-ray communication during spacecraft reentry blackout
    Liu, Yunpeng
    Dang, Peng
    Tang, Xiaobin
    Mu, Junxu
    Feng, Zhaopeng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1013
  • [4] Optimization of Detection Angle for Pinhole X-Ray Fluorescence Computed Tomography
    Guo Jing
    Feng Peng
    Deng Luzhen
    Luo Yan
    He Peng
    Wei Biao
    ACTA OPTICA SINICA, 2020, 40 (01)
  • [5] GaN-based PIN detectors for X-ray detector
    Fu K.
    Yu G.-H.
    Lu M.
    Faguang Xuebao/Chinese Journal of Luminescence, 2011, 32 (07): : 720 - 723
  • [6] X-ray detectors based on Fe doped GaN photoconductors
    Fu, Kai
    Yu, Guohao
    Yao, Changsheng
    Wang, Guo
    Lu, Min
    Zhang, Guoguang
    PHYSICA STATUS SOLIDI-RAPID RESEARCH LETTERS, 2011, 5 (5-6): : 187 - 189
  • [7] Simple techniques for measuring the performance of 2D X-ray detectors
    Adam, Martin
    He, Tim
    Durst, Roger
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2011, 67 : C809 - C809
  • [8] Truly hybrid x-ray/MR imaging: Toward a streamlined clinical system
    Ganguly, A
    Wen, ZF
    Daniel, BL
    Butts, K
    Kee, ST
    Rieke, V
    Do, HM
    Pelc, NJ
    Alley, MT
    Fahrig, R
    ACADEMIC RADIOLOGY, 2005, 12 (09) : 1167 - 1177
  • [9] Image quality in x-ray microtomography
    Davis, GR
    DEVELOPMENTS IN X-RAY TOMOGRAPHY, 1997, 3149 : 213 - 221
  • [10] X-Ray and Fast Neutron Radiographic Performance of an Ir-Bi-Plastic Array
    Decker, Andrew W.
    Cherepy, Nerine J.
    Hok, Saphon
    Hausladen, Paul A.
    Delzer, Cordell J.
    Hayward, Jason P.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (01) : 28 - 36