Comparison of minimally invasive percutaneous plate osteosynthesis with open reduction and internal fixation in distal tibial fracture

被引:0
|
作者
Department of Orthopedics, Ninth People's Hospital of Wuxi City, Wuxi, Jiangsu Province [1 ]
214062, China
机构
[1] Department of Orthopedics, Ninth People's Hospital of Wuxi City, Wuxi, Jiangsu Province
来源
J. Comput. Theor. Nanosci. | / 11卷 / 4340-4344期
关键词
Distal tibial fracture; Meta analysis; MIPPO; ORIF;
D O I
10.1166/jctn.2015.4362
中图分类号
学科分类号
摘要
Objective: To compare and analyze the efficacy of minimally invasive percutaneous plate osteosynthesis (MIPPO) and open reduction and internal fixation (ORIF) in treatment of distal tibial fracture. Methods: The relevant literatures at home and abroad were retrievedby computer in Pubmed, Embase, the Cochrane Collaboration, Chinese Biomedical Database, China National Knowledge Infrastructure (CNKI), Wanfang Data and VIP information database, and by manual searching in orthopaedic magazines in both Chinese and English. The articles including the comparison of the efficacy of MIPPO and ORIF in treatment of distal tibial fracture were collected and conducted meta analysis via Rev Man 5.2 software. Results: A total of eight studies including 603 patients were eligible for final analyses. Results of meta analysis indicated that the operative time, intraoperative blood loss and hospital stays of MIPPO group were significantly less than those of ORIF group (P <0.05). However, the two groups had no significant difference in the comparisons of healing time, incidence of adverse events related to bone healing, and excellent and good rate of J-W function evaluation (P >0.05). Conclusion: Both MIPPO and ORIF had good curative effect in treatment of distal tibial fracture. Nevertheless, MIPPO had more advantages in decreasing the surgical injury and saving medical expenses. © 2015 American Scientific Publishers.
引用
收藏
页码:4340 / 4344
页数:4
相关论文
共 50 条
  • [41] A short term functional outcome study comparing closed reduction percutaneous wire fixation with open reduction internal fixation for fractures of the distal radius: a pilot study
    Cooper, Lisa
    Mauffrey, Cyril
    Hull, Peter
    Brewster, Mark
    Lewis, Charlie
    Makrides, Panos
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2008, 18 (08) : 551 - 554
  • [42] A short term functional outcome study comparing closed reduction percutaneous wire fixation with open reduction internal fixation for fractures of the distal radius: a pilot study
    Lisa Cooper
    Cyril Mauffrey
    Peter Hull
    Mark Brewster
    Charlie Lewis
    Panos Makrides
    European Journal of Orthopaedic Surgery & Traumatology, 2008, 18 : 551 - 554
  • [43] Operative treatment of clavicle midshaft fractures using a locking compression plate: Comparison between mini-invasive plate osteosynthesis (MIPPO) technique and conventional open reduction
    Jiang, H.
    Qu, W.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (06) : 666 - 671
  • [44] Olecranon Osteotomy Fixation Following Distal Humerus Open Reduction and Internal Fixation: Clinical Results of Plate and Screws Versus Tension Band Wiring
    Haglin, Jack M.
    Lott, Ariana
    Kugelman, David N.
    Bird, Mackenzie
    Konda, Sanjit R.
    Tejwani, Nirmal C.
    Egol, Kenneth A.
    ORTHOPEDICS, 2021, 44 (01) : E107 - E113
  • [45] Open fracture of Metatarsus III/IV treated by open reduction and internal fixation in an alpaca
    Zanolari, P
    Zulauf, M
    Nitzl, D
    Ueltschi, G
    Steiner, A
    SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 2003, 145 (08): : 378 - 385
  • [46] Open reduction and internal fixation of humeral midshaft fractures: anterior versus posterior plate fixation
    Lotzien, Sebastian
    Hoberg, Clemens
    Rausch, Valentin
    Rosteius, Thomas
    Schildhauer, Thomas Armin
    Gessmann, Jan
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
  • [47] Open reduction and internal fixation of humeral midshaft fractures: anterior versus posterior plate fixation
    Sebastian Lotzien
    Clemens Hoberg
    Valentin Rausch
    Thomas Rosteius
    Thomas Armin Schildhauer
    Jan Gessmann
    BMC Musculoskeletal Disorders, 20
  • [48] Comparative study of the closed reduction percutaneous cannulated screw fixation and open reduction palmar locking plate fixation in the treatment of AO type A2 distal radius fractures
    Gereli, Arel
    Nalbantoglu, Ufuk
    Kocaoglu, Baris
    Turkmen, Metin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (01) : 121 - 129
  • [49] Percutaneous pinning versus volar locking plate internal fixation for unstable distal radius fractures: a meta-analysis
    Peng, Fei
    Liu, Yuan-xiang
    Wan, Zhen-yu
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (02) : 158 - 167
  • [50] Arthroscopic-assisted versus fluoroscopic-assisted open reduction and internal fixation for distal radius fracture: A systematic review and meta-analysis
    Chen, Keyi
    Yang, Shun
    Cheng, Yabo
    Xiang, Wang
    MEDICINE, 2025, 104 (06) : e41434