Determination of Trace Niobium and Tantalum in Rock Sample by Atomic Emission Spectrometry
被引:0
作者:
Li, Hui-Zhi
论文数: 0引用数: 0
h-index: 0
机构:
Department of Applied Chemistry, Jinan University, Jinan 250022, ChinaDepartment of Applied Chemistry, Jinan University, Jinan 250022, China
Li, Hui-Zhi
[1
]
Zhou, Chang-Li
论文数: 0引用数: 0
h-index: 0
机构:
Department of Applied Chemistry, Jinan University, Jinan 250022, ChinaDepartment of Applied Chemistry, Jinan University, Jinan 250022, China
Zhou, Chang-Li
[1
]
Luo, Chuan-Nan
论文数: 0引用数: 0
h-index: 0
机构:
Department of Applied Chemistry, Jinan University, Jinan 250022, ChinaDepartment of Applied Chemistry, Jinan University, Jinan 250022, China
Luo, Chuan-Nan
[1
]
机构:
[1] Department of Applied Chemistry, Jinan University, Jinan 250022, China
来源:
Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis
|
2002年
/
22卷
/
05期
关键词:
D O I:
暂无
中图分类号:
学科分类号:
摘要:
This paper describes the determination of trace Nb and Ta in sample using carbon powder and hafnium oxide as buffer by atomic emission spectrometry (AES). Hafnium has been selected as intecnal standard, since it has scinilar evaporation curve as those of Nb and Ta. Samples can be analyzed without chemical pretreatment. The sample was directly loaded onto the ordinary electrode. The method is simple, rapid and accurate. The range of detecmination for Nb and Ta are 0%-0.25% and 0%-0.125% respectively, and the detection limits are found to be 0.003 % and 0.001 %, respectively. Satisfactory results are obtained.