Determination of erbium by using fast neutron induced gamma-ray activation analysis

被引:0
作者
Cheng, Can [1 ,2 ]
Jia, Wenbao [3 ]
Gu, Jiayu [2 ]
Hu, Zunhao [2 ]
Xing, Liteng [2 ]
Xia, Xunrong [2 ]
Zhang, Yan [4 ]
机构
[1] Nanjing Tech University, Nanjing
[2] Jiangsu Institute of Metrology, Jiangsu Energy Measurement Data Center, Nanjing
[3] Nanjing University of Aeronautics and Astronautics, Nanjing
[4] East China University of Technology, Nanchang
来源
He Jishu/Nuclear Techniques | 2024年 / 47卷 / 10期
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Erbium oxide; Mass detection limit; Neutron generator; Prompt gamma-ray neutron activation analysis;
D O I
10.11889/j.0253-3219.2024.hjs.47.100202
中图分类号
学科分类号
摘要
]Background] In the process of nuclear fuel generation, neutron poisons are added to enhance performance of nuclear fuel. Erbium is a common neutron poison, and its content needs to be measured and analyzed during the production of such nuclear fuels. The traditional methods have limited penetration and can only analyze the surface of the samples, unable to penetrate the bulk nuclear fuel materials for internal component analysis. Prompt Gamma-ray Neutron Activation Analysis (PGNAA) is a non-destructive testing technique, which is suitable for detecting large samples. ]Purpose] This study aims to explore the feasibility of determining the erbium in large samples based on PGNAA technology. ]Methods] Firstly, a deuterium-tritium (D-T) neutron generator and a high-purity germanium (HPGe) detector were employed to establish a measurement platform. Erbium oxide was selected as the sample, and measurements were conducted utilizing the 815.9 keV peak emitted from the reaction of fast neutrons with erbium. Then, the neutron yield of D-T neutron generator was calculated using copper foil activation and Monte Carlo simulations, and the neutron spectrum at sample position was calculated using Monte Carlo simulation for observing the thermal and fast neutron fluxes. Finally, the calibration curve and mass detection limit were analyzed. ]Results] Measurement results show that the neutron yield of D-T neutron generator is (2.34±0.01)× 106 s-1 and the fast neutron flux at sample position is 106 cm-2∙s-1. Analysis results demonstrate that there is a good linear relationship between the 815.9 keV peak counts and the mass of erbium. The mass detection limit for erbium is 28 g. In addition, there is no interference between the intrinsic gamma ray of238U and the 815.9 keV Er peak. ]Conclusions] This study verifies the feasibility of PGNAA technology for the erbium determination, which can be used for further analysis of erbium in nuclear fuel. © 2024 Science Press. All rights reserved.
引用
收藏
相关论文
共 26 条
  • [1] LI Mancang, YU Yingrui, XIAO Peng, Et al., Neutron analysis of combustible poisons in long-cycle reactor core by enriched isotopes, Nuclear Power Engineering, 40, S2, pp. 74-77, (2019)
  • [2] Reda S M, Mustafa S S, Elkhawas N A., Investigating the performance and safety features of pressurized water reactors using the burnable poisons, Annals of Nuclear Energy, 141, (2020)
  • [3] Yamasaki M, Unesaki H, Yamamoto A, Et al., Development of erbia-credit super-high-burnup fuel: assessment of fuel cycle economics[J], Nuclear Technology, 183, 2, pp. 178-193, (2013)
  • [4] ZHANG Jia, LI Jia, KANG Wu, Et al., Research of main influencing factors during sol-gel preparing process of U-Zr-Hf burable poison fuel[J], Nuclear Power Engineering, 40, 5, pp. 79-84, (2019)
  • [5] WANG Zhanming, ZHAO Feng, WANG Peng, Et al., Determination of erbium in erbium nitrate solution by X-ray fluorescence spectrometry[J], Metallurgical Analysis, 37, 1, pp. 76-80, (2017)
  • [6] Su Y Y, Wang W, Li Z M, Et al., Direct detection and isotope analysis of individual particles in suspension by single particle mode MC-ICP-MS for nuclear safety[J], Journal of Analytical Atomic Spectrometry, 30, 5, pp. 1184-1190, (2015)
  • [7] Revay Z., Determining elemental composition using prompt γ activation analysis[J], Analytical Chemistry, 81, 16, pp. 6851-6859, (2009)
  • [8] Jia W B, Cheng C, Shan Q, Et al., Study on the elements detection and its correction in aqueous solution[J], Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 342, pp. 240-243, (2015)
  • [9] Xie Y J, Cheng C, Zhang W, Et al., Feasibility study of online monitoring gadolinium based on neutron induced gamma activation, Applied Radiation and Isotopes: Including Data, Instrumentation and Methods for Use in Agriculture, Industry and Medicine, 197, (2023)
  • [10] Naqvi A A, Khiari F Z, Maslehuddin M, Et al., Pulse height tests of a large diameter fast LaBr<sub>3</sub>:Ce scintillation detector[J], Applied Radiation and Isotopes, 104, pp. 224-231, (2015)