Parameter identification based on vector fitting method for extended debye model of oil-paper insulation system

被引:0
作者
Tang, Mingjie [1 ]
Lei, Min [1 ]
Bai, Fan [1 ]
Wei, Jianlin [2 ]
Xu, Hao [3 ]
Zhang, Guanjun [1 ]
机构
[1] State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University
[2] Henan Electric Power Research Institute
[3] Jiaozuo Power Supply Company
来源
Gaodianya Jishu/High Voltage Engineering | 2014年 / 40卷 / 02期
关键词
Extended Debye model; Fast Fourier transform; Frequency domain spectrum; Oil-paper insulation; Parameter identification; Polarization and depolarization current; Vector fitting method;
D O I
10.13336/j.1003-6520.hve.2014.02.030
中图分类号
学科分类号
摘要
In order to obtain more specific information of insulation states of oil-paper insulation system from time-domain data, we proposed a novel method for parameter identification of extended Debye model for oil-paper insulation system. In the method, the depolarization current spectrum of polarization and depolarization current (PDC) in experiments was obtained by the fast Fourier transform (FFT). Then combining the vector fitting method (VFM) and nonlinear fitting algorithm (FNA), we derived the distribution of the poles and residues of the obtained spectrum, and calculated the branch parameters of extended Debye models. The PDC and frequency domain spectrum (FDS) measurements were performed on some oil-impregnated pressboard samples, which were in various aging states and under different temperatures. The corresponding extended Debye models to the samples were obtained from the PDC measurement, based on which curves of tanδ varying with frequency were figured out and then compared with those from FDS measurements. The tanδ obtained from PDC agrees well with that from FDS under low frequencies, which verifies the proposed method. With further analysis, it is suggested that, for oil-paper insulation system, FDS measurement should be conducted in high frequency range but replaced by PDC measurement in low frequency range, for saving time, i. e. the combination of FDS and PDC methods could help to improve the efficiency of measurement of on-site oil-paper equipment.
引用
收藏
页码:548 / 556
页数:8
相关论文
共 27 条
[1]  
Saha T.K., Purkait P., Muller F., Et al., Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements, IEEE Transactions on Power Delivery, 20, 1, pp. 149-157, (2005)
[2]  
Saha T.K., Middleton R., Thomas A., Et al., Understanding frequency & time domain polarisation methods for the insulation, Power & Energy Society General Meeting, pp. 26-30, (2009)
[3]  
Saha T.K., Purkait P., Mullert F., Et al., An attempt to correlate time & frequency domain polarisation measurements for the insulation diagnosis of power transformer, Power & Energy Society General Meeting, pp. 1793-1798, (2004)
[4]  
Saha T.K., Pradhan M.K., Yew J.H., Optimal time selection for the polarization and depolarization current measurement for power transformer insulation diagnosis, Power Engineering Society General Meeting, pp. 1-7, (2007)
[5]  
Liao R., Sun H., Yuan Q., Et al., Analysis of oil-paper insulation aging characteristics using recovery voltage method, High Voltage Engineering, 37, 1, pp. 136-142, (2011)
[6]  
Zhou L., Li X., Wu G., Et al., Low frequency dispersion mechanism of dielectric response for oil-paper insulation diagnosis, High Voltage Engineering, 39, 8, pp. 1873-1880, (2013)
[7]  
Li G., Jiang X., Cai J., Et al., Dielectric response function for transformer oil-paper insulation solved by the method of differential depolarization current, High Voltage Engineering, 38, 8, pp. 1930-1935, (2012)
[8]  
Zhang Z., Dong M., Peng H., Et al., Insulation diagnosis of high voltage current transformer by frequency dielectric spectroscopy, High Voltage Engineering, 38, 11, pp. 2949-2954, (2012)
[9]  
Wei J., Wang S., Wu F., Et al., Simulation on variation of electrical insulation parameters in predictive test caused by insulation aging of power transformer, High Voltage Engineering, 35, 7, pp. 1618-1623, (2009)
[10]  
Hao J., Liao R.J., Chen G., Et al., Assessing ageing condition of natural ester-paper insulation and mineral oil-paper insulation by polarization and depolarization current, IEEE Transactions on Dielectrics and Electrical Insulation, 19, 1, pp. 188-199, (2012)