Comprehensive Inspection Solution for Boiler Water Wall Tube Corrosion
被引:0
作者
:
Lee, Ping Hung
论文数:
0
引用数:
0
h-index:
0
机构:
Guided Wave Ltd, Chinese Taipei, Kaohsiung, Taiwan
Guided Wave Ltd, Chinese Taipei, Kaohsiung, Taiwan
Lee, Ping Hung
[
1
]
Ma, Pei Hua
论文数:
0
引用数:
0
h-index:
0
机构:
Guided Wave Ltd, Chinese Taipei, Kaohsiung, Taiwan
Guided Wave Ltd, Chinese Taipei, Kaohsiung, Taiwan
Ma, Pei Hua
[
1
]
Owens, Steve
论文数:
0
引用数:
0
h-index:
0
机构:
Guidedwave (FBS, Inc. d.b.a.), PA, United States
Guided Wave Ltd, Chinese Taipei, Kaohsiung, Taiwan
Owens, Steve
[
2
]
Borigo, Cody
论文数:
0
引用数:
0
h-index:
0
机构:
Guidedwave (FBS, Inc. d.b.a.), PA, United States
Guided Wave Ltd, Chinese Taipei, Kaohsiung, Taiwan
Borigo, Cody
[
2
]
机构
:
[1]
Guided Wave Ltd, Chinese Taipei, Kaohsiung, Taiwan
[2]
Guidedwave (FBS, Inc. d.b.a.), PA, United States
来源
:
e-Journal of Nondestructive Testing
|
2024年
/ 29卷
/ 06期
关键词
:
A substantial number of domestic coal-fired boilers;
most of which have been in operation for numerous years;
are susceptible to corrosion and tube ruptures within their high-temperature environment;
often resulting in unplanned shutdowns. Despite the annual planned maintenance shutdowns;
which involve routine inspections of water wall and furnace tubes to detect potential corrosion and erosion;
the current non-destructive testing methods are generally localized. This approach;
particularly with the considerable height variation of the water wall tubes (ranging from approximately 10 to 25 meters);
may overlook segments with severe corrosion during localized ultrasonic thickness gauging. Although the experience of inspection teams reduces the chance of defect oversight;
the demand for a comprehensive and effective inspection technique remains a priority for boiler operators. This study utilizes the characteristic of guided waves to propagate over a certain distance along pipelines;
initiating an exploration into a comprehensive inspection solution for water wall tubes. Finite element simulation results demonstrate the suitability of utilizing a 120 kHz frequency for shear horizontal mode (SH0) testing on the fire side of water wall tubes. This mode effectively screens for localized corrosion within a 3-meter range. In the field of on-site boiler inspection;
electromagnetic coils are employed to generate guided waves within water wall tubes. The gathered signals from each electromagnetic guided wave testing (EMGWT) are consolidated into a distribution map;
indicating suspicious signal locations. Pulse eddy current testing (PECT) is employed to identify potential issues with guided waves without requiring surface preparation. If PECT reveals anomalies;
the affected surface is polished;
and phased array ultrasonic testing (PAUT) is conducted to quantitatively measure the remaining wall thickness due to corrosion. The theoretical exploration and on-site inspection outcomes affirm the feasibility of this approach;
aimed at enhancing operational safety for boiler water wall tubes and mitigating the risks of tube ruptures and leaks. This comprehensive inspection solution amalgamates three advanced detection technologies;
each capitalizing on its unique inspection characteristics to facilitate corrosion screening;
corrosion scanning;
and wall thickness sizing. Through the integration of these technologies;
the overall inspection strategy ensures the utmost level of reliability. © 2024 The Authors;