Robust Detection and Location of Inter-turn Short Circuit Fault in Permanent Magnet Synchronous Motor Based on Square of Residual Current Vector Modulus

被引:0
作者
Hang J. [1 ]
Hu Q. [1 ]
Ding S. [1 ]
Sun W. [1 ]
Ren X. [1 ]
机构
[1] School of Electrical Engineering and Automation, Anhui University, Hefei
来源
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering | 2022年 / 42卷 / 01期
基金
中国国家自然科学基金; 安徽省自然科学基金;
关键词
Inter-turn fault; Luenberger observer; Permanent magnet synchronous motor; Residual current;
D O I
10.13334/j.0258-8013.pcsee.211822
中图分类号
学科分类号
摘要
In this paper, a robust detection and location method for inter-turn short circuit fault in permanent magnet synchronous motor (PMSM) was proposed based on square of residual current vector modulus. The mathematical models of the PMSM under healthy and fault conditions were presented in dq rotating frame. On this basis, the Luenberger observer was used to estimate dq-axis residual currents owing to the inter-turn short circuit fault. The fault detection index and fault phase location index were reconstructed based on second harmonic component in the square of residual current vector modulus. Both the simulation and experimental results validate that the proposed method could effectively achieve the inter-turn short circuit fault detection and the faulty phase location. Additionally, the proposed method did not require additional hardware and had good robustness against parameter mismatch and rotating speed variation. © 2022 Chin. Soc. for Elec. Eng.
引用
收藏
页码:340 / 350
页数:10
相关论文
共 35 条
[11]  
YANG Zhi, SHI Xiaodong, KRISHNAMURTHY M., Vibration monitoring of PM synchronous machine with partial demagnetization and inter-turn short circuit faults, Proceedings of 2014 IEEE Transportation Electrification Conference and Expo, (2014)
[12]  
ARELLANO-PADILLA J, SUMNER M, GERADA C., Winding condition monitoring scheme for a permanent magnet machine using high-frequency injection, IET Electric Power Applications, 5, 1, pp. 89-99, (2011)
[13]  
DA Yao, SHI Xiaodong, KRISHNAMURTHY M., A new approach to fault diagnostics for permanent magnet synchronous machines using electromagnetic signature analysis, IEEE Transactions on Power Electronics, 28, 8, pp. 4104-4112, (2013)
[14]  
HENAO H, DEMIAN C, CAPOLINO G A., A frequency-domain detection of stator winding faults in induction machines using an external flux sensor, IEEE Transactions on Industry Applications, 39, 5, pp. 1272-1279, (2003)
[15]  
LI Yonggang, LI Heming, ZHAO Hua, Et al., Fault identification method of rotor inter turn short-circuit using stator winding detection, Proceedings of the CSEE, 24, 2, pp. 107-112, (2004)
[16]  
URRESTY J C, RIBA J R, DELGADO M, Et al., Detection of demagnetization faults in surface-mounted permanent magnet synchronous motors by means of the zero-sequence voltage component, IEEE Transactions on Energy Conversion, 27, 1, pp. 42-51, (2012)
[17]  
HANG Jun, ZHANG Jianzhong, CHENG Ming, Et al., Online interturn fault diagnosis of permanent magnet synchronous machine using zero-sequence components, IEEE Transactions on Power Electronics, 30, 12, pp. 6731-6741, (2015)
[18]  
XU Boqiang, LI Heming, SUN Liling, Et al., Detection of stator winding inter-turn short circuit fault in induction motors, Proceedings of the CESS, 24, 7, pp. 177-182, (2004)
[19]  
ROMERAL L, URRESTY J C, RUIZ J R R, Et al., Modeling of surface-mounted permanent magnet synchronous motors with stator winding interturn faults, IEEE Transactions on Industrial Electronics, 58, 5, pp. 1576-1585, (2011)
[20]  
NIU Huamin, GUI Ling, SUN Yuguang, Et al., Simulation and experimental research on stator winding internal faults of AC excitation machine based on multi-loop theory, Proceedings of the CSEE, 39, 12, pp. 3676-3684, (2019)