Performance of the Iterative OSEM and HYPER Algorithm for Total-body PET at SUVmax with a Low 18F-FDG Activity, a Short Acquisition Time and Small Lesions

被引:2
作者
Zan, Keyu [1 ,2 ]
Duan, Yanhua [1 ,2 ]
Zhao, Minjie [1 ,2 ]
Li, Hui [1 ,2 ]
Cui, Xiao [1 ,2 ]
Chai, Leiying [1 ,2 ]
Cheng, Zhaoping [1 ,2 ]
机构
[1] Shandong First Med Univ, Affiliated Hosp 1, Dept Nucl Med, Jinan, Peoples R China
[2] Shandong Prov Qianfoshan Hosp, Jinan, Peoples R China
基金
中国国家自然科学基金;
关键词
Positron-emission tomography; Reconstruction; Image quality; NEMA; Acquisition time; Injection activity; PENALIZED LIKELIHOOD RECONSTRUCTION; CLINICAL-EVALUATION;
D O I
10.2174/0115734056274225240109112413
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective:The primary objective of this comparative investigation was to examine the qualitative attributes of image reconstructions utilizing two distinctalgorithms, namely OSEM and HYPER Iterative, in total-body 18F- FDG PET/CT under various acquisition durations and injection activities. Methods:An initial assessment was executed using a NEMA phantom to compare image quality engendered by OSEM and HYPER Iterative algorithms.Parameters such as BV, COV, and CRC were meticulously evaluated. Subsequently, a prospective cohort study was conducted on 50 patients,employing both reconstruction algorithms. The study was compartmentalized into distinct acquisition time and dosage groups. Lesions werefurther categorized into three size-based groups. Quantifiable metrics including SD of noise, SUVmax, SNR, and TBR were computed. Additionally,the differences in values, namely Delta SUVmax, Delta TBR, %Delta SUVmax, %Delta SD, and %Delta SNR, between OSEM and HYPER Iterative algorithms were alsocalculated. Results:The HYPER Iterative algorithm showed reduced BV and COV compared to OSEM in the phantom study, with constant acquisition time. In theclinical study, lesion SUVmax, TBR, and SNR were significantly elevated in images reconstructed using the HYPER Iterative algorithm incomparison to those generated by OSEM (p < 0.001). Furthermore, an amplified increase in SUVmax was predominantly discernible in lesions withdimensions less than 10 mm. Metrics such as %Delta SNR and %Delta SD in HYPER Iterative exhibited improvements correlating with reducedacquisition times and dosages, wherein a more pronounced degree of enhancement was observable in both Delta SUVmax and Delta TBR. Conclusion:The HYPER Iterative algorithm significantly improves SUVmax and reduces noise level, with particular efficacy in lesions measuring <= 10 mm andunder conditions of abbreviated acquisition times and lower dosages.
引用
收藏
页数:11
相关论文
共 22 条
[1]   Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET [J].
Ahn, Sangtae ;
Ross, Steven G. ;
Asma, Evren ;
Miao, Jun ;
Jin, Xiao ;
Cheng, Lishui ;
Wollenweber, Scott D. ;
Manjeshwar, Ravindra M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15) :5733-5751
[2]   First Human Imaging Studies with the EXPLORER Total-Body PET Scanner [J].
Badawi, Ramsey D. ;
Shi, Hongcheng ;
Hu, Pengcheng ;
Chen, Shuguang ;
Xu, Tianyi ;
Price, Patricia M. ;
Ding, Yu ;
Spencer, Benjamin A. ;
Nardo, Lorenzo ;
Liu, Weiping ;
Bao, Jun ;
Jones, Terry ;
Li, Hongdi ;
Cherry, Simon R. .
JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (03) :299-303
[3]   Effect of a Bayesian Penalized Likelihood PET Reconstruction Compared With Ordered Subset Expectation Maximization on Clinical Image Quality Over a Wide Range of Patient Weights [J].
Chilcott, Anna K. ;
Bradley, Kevin M. ;
McGowan, Daniel R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (01) :153-157
[4]   Comparison of Bayesian penalized likelihood reconstruction versus OS-EM for characterization of small pulmonary nodules in oncologic PET/CT [J].
Howard, Brandon A. ;
Morgan, Rustain ;
Thorpe, Matthew P. ;
Turkington, Timothy G. ;
Oldan, Jorge ;
James, Olga G. ;
Borges-Neto, Salvador .
ANNALS OF NUCLEAR MEDICINE, 2017, 31 (08) :623-628
[5]   Evaluation of Penalized-Likelihood Estimation Reconstruction on a Digital Time-of-Flight PET/CT Scanner for 18F-FDG Whole-Body Examinations [J].
Lindstrom, Elin ;
Sundin, Anders ;
Trampal, Carlos ;
Lindsjo, Lars ;
Ilan, Ezgi ;
Danfors, Torsten ;
Antoni, Gunnar ;
Sorensen, Jens ;
Lubberink, Mark .
JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (07) :1152-1158
[6]   Evaluation and Optimization of a New PET Reconstruction Algorithm, Bayesian Penalized Likelihood Reconstruction, for Lung Cancer Assessment According to Lesion Size [J].
Otani, Tomoaki ;
Hosono, Makoto ;
Kanagaki, Mitsunori ;
Onishi, Yasuyuki ;
Matsubara, Naoko ;
Kawabata, Kazuna ;
Kimura, Hiroyuki .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (02) :W50-W56
[7]   Phantom, clinical, and texture indices evaluation and optimization of a penalized-likelihood image reconstruction method (Q.Clear) on a BGO PET/CT scanner [J].
Reynes-Llompart, Gabriel ;
Gamez-Cenzano, Cristina ;
Luis Vercher-Conejero, Jose ;
Sabate-Llobera, Aida ;
Calvo-Malvar, Nahum ;
Marti-Climent, Josep M. .
MEDICAL PHYSICS, 2018, 45 (07) :3214-3222
[8]   Performance Evaluation of the uEXPLORER Total-Body PET/CT Scanner Based on NEMA NU 2-2018 with Additional Tests to Characterize PET Scanners with a Long Axial Field of View [J].
Spencer, Benjamin A. ;
Berg, Eric ;
Schmall, Jeffrey P. ;
Omidvari, Negar ;
Leung, Edwin K. ;
Abdelhafez, Yasser G. ;
Tang, Songsong ;
Deng, Zilin ;
Dong, Yun ;
Lv, Yang ;
Bao, Jun ;
Liu, Weiping ;
Li, Hongdi ;
Jones, Terry ;
Badawi, Ramsey D. ;
Cherry, Simon R. .
JOURNAL OF NUCLEAR MEDICINE, 2021, 62 (06) :861-870
[9]   Exploration of the total-body PET/CT reconstruction protocol with ultra-low 18F-FDG activity over a wide range of patient body mass indices [J].
Sui, Xiuli ;
Tan, Hui ;
Yu, Haojun ;
Xiao, Jie ;
Qi, Chi ;
Cao, Yanyan ;
Chen, Shuguang ;
Zhang, Yiqiu ;
Hu, Pengcheng ;
Shi, Hongcheng .
EJNMMI PHYSICS, 2022, 9 (01)
[10]   Total-body PET/CT using half-dose FDG and compared with conventional PET/CT using full-dose FDG in lung cancer [J].
Tan, Hui ;
Sui, Xiuli ;
Yin, Hongyan ;
Yu, Haojun ;
Gu, Yusen ;
Chen, Shuguang ;
Hu, Pengcheng ;
Mao, Wujian ;
Shi, Hongcheng .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (06) :1966-1975