Response function and photon interaction of LaBr3:Ce and BGO scintillation detectors by Monte Carlo simulation

被引:0
|
作者
Mutuwong C. [1 ]
Bootjomchai C. [1 ]
Chaiphaksa W. [2 ,3 ]
Yonphan S. [2 ,3 ]
Kothan S. [4 ]
Kaewkhao J. [2 ,3 ]
机构
[1] Department of Physics, Faculty of Science, Ubon Ratchathani University, Warin Chamrap, Ubon Ratchathani
[2] Physics Program, Faculty of Science and Technology, Nakhon Pathom Rajabhat University, Nakhon Pathom
[3] Center of Excellence in Glass Technology and Materials Science (CEGM), Nakhon Pathom Rajabhat University, Nakhon Pathom
[4] Center of Radiation Research and Medical Imaging, Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai
来源
Optik | 2023年 / 289卷
关键词
BGO; Gaussian energy broadening; LaBr[!sub]3[!/sub]:Ce; Monte Carlo simulation;
D O I
10.1016/j.ijleo.2023.171161
中图分类号
学科分类号
摘要
This work aims to investigate the response function and photon interaction of the LaBr3:Ce and BGO scintillation detectors using the FLUKA Monte Carlo simulation software. To improve the realism of detectors, the DETGEB card was used to activate the gaussian energy broadening (GEB) function. The GEB parameters of both detectors were obtained by fitting a nonlinear curve to the relation between FWHM and gamma-ray energy. The energy resolution (R), peak-to-Compton ratio (PCR), peak-to-total ratio (PTR), and full-energy peak efficiency (FEPE) of both detectors were investigated by simulation and experiment at different gamma-ray energy obtained from 133Ba, 137Cs, and 60Co sources. The simulated spectra of those radioisotopes were found to agree with the actual spectra. The results found that the R, PCR, and FEPE values of the LaBr3:Ce and BGO detectors tend to decrease as energy increases. Moreover, the total atomic cross-section (σt,a), effective atomic number (Zeff) and effective electron density (Neff) of both crystals was investigated by FLUKA and compared with the XCOM theoretical program covering an energy range of 15 keV to 15 MeV. The simulated results of the σt,a, Zeff, and Neff are in excellent agreement with the theoretical ones. The GEB parameters obtained from this study will improve the simulation performance of LaBr3:Ce and BGO detectors in investigating the gamma-ray response and shielding properties of materials. © 2023 Elsevier GmbH
引用
收藏
相关论文
共 50 条
  • [31] LaBr3:Ce Scintillation Imagers Optimization by GEANT4
    Lo Meo, S.
    Baldazzi, G.
    Bennati, P.
    Bollini, D.
    Cencelli, V. Orsolini
    Cinti, M. N.
    Moschini, G.
    Lanconellia, N.
    Navarria, F. L.
    Pani, R.
    Pellegrini, R.
    Perrotta, A.
    Vittorini, F.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2009, 197 : 378 - 382
  • [32] Medical gamma probe based on LaBr3:Ce scintillation crystal
    Berdnikova, A. K.
    Dubinin, F. A.
    Kantserov, V. A.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2016, 43 (08) : 249 - 251
  • [33] Analytical method to calibrate cylindrical LaBr3(Ce) scintillation detector
    Abbas, Mahmoud I.
    ADVANCES IN INNOVATIVE MATERIALS AND APPLICATIONS, 2011, 324 : 273 - 276
  • [34] Application of a LaBr3(Ce) Scintillation Detector to an Environmental Radiation Monitor
    Ji, Young-Yong
    Choi, Hee-Yeoul
    Lee, Wanno
    Kim, Chang-Jong
    Chang, Hyun-Sock
    Chung, Kun-Ho
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (08) : 2021 - 2028
  • [35] Medical gamma probe based on LaBr3:Ce scintillation crystal
    A. K. Berdnikova
    F. A. Dubinin
    V. A. Kantserov
    Bulletin of the Lebedev Physics Institute, 2016, 43 : 249 - 251
  • [36] Calculation and experiment of detective efficiency of LaBr3:Ce scintillation detector
    Lu, Yi
    Song, Zhao-Hui
    Tan, Xin-Jian
    Jiang, Wen-Gang
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2014, 48 : 623 - 626
  • [37] Performance of linear classification algorithms on α/γ discrimination for LaBr3:Ce scintillation detectors with various pulse digitizer properties
    Wen, J.
    Zhu, J.
    Xue, T.
    Cang, J.
    Wei, L.
    Nie, Q.
    Zeng, M.
    Zeng, Z.
    Ma, H.
    Lia, J.
    Liu, Y.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (02):
  • [38] Detection of Photon-Induced Excitations in 235U with LaBr3 : Ce Scintillating Detectors
    Orner, Mohamed
    Negm, Hani
    Zen, Heishun
    Hori, Toshitada
    Kii, Toshiteru
    Masuda, Kai
    Ohgaki, Hideaki
    Hajima, Ryoichi
    Hayakawa, Takehito
    Daito, Izuru
    Shizuma, Toshiyuki
    Fujiwara, Mamoru
    Park, Seong Hee
    Kikuzawa, Nobuhiro
    Rusev, Gencho
    Tonchev, Anton P.
    Wu, Ying K.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 55 - 58
  • [39] Monte Carlo simulation for performance evaluation of detector model with a monolithic LaBr3(Ce) crystal and SiPM array for γ radiation imaging
    Wei Lu
    Lei Wang
    Yong Yuan
    Ting Zhang
    Ge Tang
    Ming-Zhe Liu
    Xian-Guo Tuo
    Jing Ning
    Nuclear Science and Techniques, 2022, 33 (08) : 165 - 176
  • [40] Monte Carlo simulation for performance evaluation of detector model with a monolithic LaBr3(Ce) crystal and SiPM array for γ radiation imaging
    Lu, Wei
    Wang, Lei
    Yuan, Yong
    Zhang, Ting
    Tang, Ge
    Liu, Ming-Zhe
    Tuo, Xian-Guo
    Ning, Jing
    NUCLEAR SCIENCE AND TECHNIQUES, 2022, 33 (08)