Power flow analysis of unbalance, reactive power and harmonics in traction power supply system based on three-phase to single-phase power electronic transformer

被引:0
作者
Yan H. [1 ]
Shu Z. [1 ]
Yao J. [1 ]
Chen Y. [2 ]
Ma J. [1 ]
Du Y. [3 ,4 ]
机构
[1] School of Electrical Engineering, Southwest Jiaotong University, Chengdu
[2] State Grid Suining Electric Power Supply Company, Chengdu
[3] The Locomotive and Car Research Institute, China Railway Sciences Corporation Limited, Beijing
[4] Beijing Zongheng Electro-mechanical Technology Co., Ltd., Beijing
来源
Dianli Zidonghua Shebei/Electric Power Automation Equipment | 2019年 / 39卷 / 11期
关键词
Co-phase power supply system; Power flow calculation; Power quality; Three-phase to single-phase power electronic transformer;
D O I
10.16081/j.epae.201909045
中图分类号
学科分类号
摘要
The three-phase to single-phase power electronic transformer is applied to the co-phase power supply system. The relationships of power flow in condition of unbalance, reactive power and harmonics between the single-phase side and three-phase side on traditional transformer and power electronic transfor-mer are calculated and compared. Based on three-level circuit, the control strategies of isolated DC-DC converter and multi-model cascaded rectifier are studied. The rectifier adopts the decoupling control of active and reactive power to realize the unity power factor operation of grid side, and the isolated DC-DC converter applies the dual three-level control strategy to reduce the RMS of inductance current flowing through the medium frequency transformer. Simulative and experimental results verify that the proposed co-phase power supply system can effectively eliminate the adverse effect produced by unbalanced load, reactive power and harmonics, having good dynamic and static performance. © 2019, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:159 / 164
页数:5
相关论文
共 14 条
[1]  
Zhang G., Li Q., Transfer from out-phase power supply to in-phase power supply, Electric Power Automation Equipment, 32, 11, (2012)
[2]  
Tang H., Tang J., Lin L., Power quality management system of electrical railway based on YNVD balance transformer, Electric Power Automation Equipment, 38, 10, pp. 197-204, (2018)
[3]  
Guo X., Li Q., Xie S., Et al., Electrical cha-racteristic of cable traction network for electrified railway, Electric Power Automation Equipment, 35, 12, pp. 132-137, (2015)
[4]  
Xia Y., Li Q., Xie S., Et al., Negative sequence compensation of high-speed and heavy-haul electric railroad with V-connection transformer, Electric Power Automation Equipment, 34, 2, pp. 73-78, (2014)
[5]  
Wu C., Luo A., Xu X., Et al., Integrative compensation method of negative phase sequence and harmonic for high-speed railway traction supply system with V/v transformer, Proceedings of the CSEE, 30, 16, pp. 111-117, (2010)
[6]  
Shu Z., Xie S., Li Q., Et al., Single-phase back-to-back converter for active power balancing, reactive power compensation, and harmonic filtering in traction power system, IEEE Transactions on Power Electronics, 26, 1, pp. 334-343, (2011)
[7]  
Ma Q., Tan L., Luo P., Optimal negative-sequence compensation of hybrid power-quality management system for V/v traction substation, Electric Power Automation Equipment, 37, 4, pp. 128-132, (2017)
[8]  
Wang G., Chang W., Bak C.L., Et al., Control strategy for combined co-phase power supply system based on theory of control without harmonic detection and selective harmonic compensation, Electric Power Automation Equipment, 37, 12, pp. 130-137, (2017)
[9]  
Sabahi M., Goharrizi A.Y., Hosseini S.H., Et al., Fle-xible power electronic transformer, IEEE Transactions on Industry and General Applications, 25, 8, pp. 2159-2169, (2010)
[10]  
Liu J., Yang J., Zhang J., Et al., Voltage balance control based on dual active bridge DC/DC con-verters in a power electronics traction transformer, IEEE Transactions on Power Electronics, 33, 2, pp. 1696-1714, (2018)