Research on Flow Distribution Characteristics of Inverted U- Shaped Tube of Steam Generator under Natural Circulation Condition

被引:0
作者
Zhao P. [1 ,2 ]
Yi F. [2 ]
Yu H. [1 ]
Shi W. [3 ]
Wang T. [2 ]
Xia B. [1 ]
Chen B. [1 ]
机构
[1] Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, Chengdu
[2] School of Nuclear Science and Technology, University of South China, Hengyang
[3] Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei
来源
Hedongli Gongcheng/Nuclear Power Engineering | 2021年 / 42卷 / 01期
关键词
Flow distribution; Natural circulation; Steam generator; U-tube flow reverse;
D O I
10.13832/j.jnpe.2021.01.0192
中图分类号
学科分类号
摘要
Taking the steam generator of the primary circuit system of the PACTEL PWR thermal experiment device as the research object, the pressure drop and the relationship between heat transfer and fluid flow of the U-tube are established based on the equations of mass conservation, momentum conservation and energy conservation of the one-dimensional fluid flow model. Then, the flow distribution calculation program of the inverted U-tube steam generator based on genetic algorithm was developed, and the correctness and reliability of the program were verified by benchmark experiments. Finally, the flow distribution among the U-tube groups of the steam generator is calculated by using the flow distribution program, and the influences of the tube height, tube length and the heat transfer coefficient of the first/second side on the flow distribution within the steam generator are studied. The results of the developed flow allocator are in good agreement with the experiment. Under the selected natural cycle conditions, the backflow is more likely to occur in the long tube of the steam generator, and the backflow phenomenon is characterized by a wide distribution range and low single-tube flow rate. The velocity of the forward flow in an inverted U-tube is inversely proportional to the length of the tube and proportional to the height of the tube. The backflow velocity remained unchanged with the increase of pipe length and was inversely proportional to pipe height. When the coefficient of heat transfer is low, the total flow is inversely proportional to the heat transfer coefficient. When the heat transfer coefficient is higher than a specific value, the backflow occurs in part of the tubes and the total flow drops sharply. © 2021, Editorial Board of Journal of Nuclear Power Engineering. All right reserved.
引用
收藏
页码:192 / 197
页数:5
相关论文
共 10 条
  • [1] JEONG J J, HWANG M, LEE Y J, Et al., Non-uniform flow distribution in the steam generator U-tubes of a pressurized water reactor plant during single-and two-phase natural circulations, Nuclear Engineering and Design, 231, 3, pp. 303-314, (2004)
  • [2] WATANABE T, ANODA Y, TAKANO M., Stability of single-phase natural-circulation flows in steam generator U tubes, Annals of Nuclear Energy, 60, pp. 344-349, (2013)
  • [3] 1
  • [4] 4
  • [5] PURHONEN H, PUUSTINEN M, RIIKONEN V, Et al., PACTEL integral test facility-description of versatile applications, Annals of Nuclear Energy, 33, 11-12, pp. 994-1009, (2006)
  • [6] ISHII M, KATAOKA I., Scaling laws for thermal- hydraulic system under single phase and two-phase natural circulation, Nuclear Engineering and Design, 81, 3, pp. 411-425, (1984)
  • [7] HAO J, CHEN W, ZHANG D, Et al., Scaling modeling analysis of flow instability in U-tubes of steam generator under natural circulation, Annals of Nuclear Energy, 64, pp. 169-175, (2014)
  • [8] SANDERS J., Stability of single-phase natural circulation with inverted U-tube steam generators, Journal of Heat Transfer, 110, 3, pp. 735-742, (1988)
  • [9] pp. 17-18, (2018)
  • [10] HOVI V, PATTIKANGAS T, RIIKONEN V., Coupled one-dimensional and CFD models for the simulation of steam generators, Nuclear Engineering and Design, 310, pp. 93-111, (2016)