Study on shunt active power filter control strategies of three-phase grid-connected photovoltaic systems

被引:0
作者
Chelli Z. [1 ]
Lakehal A. [2 ]
Khoualdia T. [2 ]
Djeghader Y. [1 ]
机构
[1] Department of Electrical Engineering, Faculty of Science and Technology, Mohamed-Cherif Messaadia University, P.O. Box 1553, Souk Ahras
[2] Department of Mechanical Engineering, Faculty of Science and Technology, Mohamed-Cherif Messaadia University, P.O. Box 1553, Souk Ahras
来源
Periodica polytechnica Electrical engineering and computer science | 2019年 / 63卷 / 03期
关键词
Direct Power Control; Energy quality; Hysteresis Control; MPPT; Photovoltaic system;
D O I
10.3311/PPee.14025
中图分类号
学科分类号
摘要
This paper deals with the improvement of the energy quality using shunt active power filter. The three-phase grid-connected photovoltaic generator consists in solar panels, a three-phase voltage inverter connected to the grid and a nonlinear load constituted by a diode rectifier bridge supplying a resistive load in series with an inductor. In so doing, three main challenges arise from the application context. First, the harmonic currents and the reactive power must be compensated. The second challenge is the injection of active solar energy into the grid. Third, Maximum Power Point Tracking (MPPT) must be found. This paper proposes a method addressing those challenges. For the first and the second one, direct current and power controls is used. For the third challenge, an algorithm is proposed which take in account the electrical variables and the variation of the solar irradiation. Simulation results of the proposed method are shown. The method is illustrated with two different strategies: Hysteresis Control and Direct Power Control (DPC) for a variable load. Obtained results are presented and compared in this paper to confirm the robustness and the superiority of DPC strategy compared to Hysteresis Control strategy. In the same context, the simulation carried out in this article shows promising results with THD approximates 1.33 %. © 2019 Budapest University of Technology and Economics. All rights reserved.
引用
收藏
页码:213 / 226
页数:13
相关论文
共 13 条
  • [11] Menon M.K.D., A novel method to extract maximum power from solar panel of a grid connected phototvoltaic system using phase angle control and hysteresis current control, International Conference on Electrical, Electronics, and Optimization Techniques (ICEEOT), pp. 3510-3516, (2016)
  • [12] Chaoui A., Krim F., Gaubert J.-P., Rambault L., DPC controlled three-phase active filter for power quality improvement, International Journal of Electrical Power and Energy Systems, 30, 8, pp. 476-485, (2008)
  • [13] Adamidis G., Tsengenes G., Kelesidis K., Three phase grid connected photovoltaic system with active and reactive power control using "instantaneous reactive power theory, Renewable Energy and Power Quality Journal, 1, 8, pp. 1086-1091, (2010)