Improving ammonia sensing performance of quartz crystal microbalance (QCM) coated with nanofibers and polyaniline (PANi) overlay

被引:0
|
作者
Aflaha R. [1 ]
Afiyanti H. [1 ]
Azizah Z.N. [1 ]
Khoirudin H. [1 ]
Rianjanu A. [2 ]
Kusumaatmaja A. [1 ]
Roto R. [3 ]
Triyana K. [1 ]
机构
[1] Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada, Sekip Utara, BLS 21, Yogyakarta
[2] Department of Materials Engineering, Institut Teknologi Sumatera, Terusan Ryacudu, Way Hui, Lampung, Jati Agung
[3] Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada, Sekip Utara, BLS 21, Yogyakarta
来源
关键词
Ammonia; Nanofiber; Polyaniline; Polyvinyl acetate; Quartz crystal microbalance;
D O I
10.1016/j.biosx.2022.100300
中图分类号
学科分类号
摘要
Ammonia gas sensors with high sensitivity, good selectivity, and superior stability continue to be developed to monitor ammonia levels in the air. In this study, we developed a sensor based on a quartz crystal microbalance coated with polyvinyl acetate (PVAc) nanofiber overlaid with a polyaniline (PANi) nanocomposite to increase the sensitivity and selectivity of the sensor. The morphology and chemical composition of the fabricated nanofibers were examined by scanning electron microscopy and Fourier transform infrared spectroscopy. PANi nanocomposites were shown to stick to nanofiber, and nanofiber became many active groups after PANi overlay. The QCM sensor coated with the PVAc nanofiber overlaid with 0.05% PANi (PVAc/PANi5) exhibited the highest sensitivity of 0.297 Hz/ppm. This value was increased 5.2 times compared to the sensor without the PANi overlay (0.055 Hz/ppm). The PVAc/PANi5 sensor exhibited good reproducibility, repeatability, and reversibility. Moreover, a rapid response (36 s) and recovery (26 s) time were observed. The sensor also showed good selectivity towards other analytes and was proven to have good long-term stability during two months of testing. This finding may potentially be an alternative method for increasing the ammonia-sensing performance of a sensor through overlaying. © 2022 The Author(s)
引用
收藏
相关论文
共 50 条
  • [31] Construction of a sensor for determination of ammonia and aliphatic amines using polyvinylpyrrolidone coated quartz crystal microbalance
    Mirmohseni, A
    Oladegaragoze, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (1-2) : 164 - 172
  • [32] Electrospun PEDOT: PSS/PVP Nanofibers for CO Gas Sensing with Quartz Crystal Microbalance Technique
    Zhang, Hong-Di
    Yan, Xu
    Zhang, Zhi-Hua
    Yu, Gu-Feng
    Han, Wen-Peng
    Zhang, Jun-Cheng
    Long, Yun-Ze
    INTERNATIONAL JOURNAL OF POLYMER SCIENCE, 2016, 2016
  • [33] Long Memory from Sauerbrey Equation: A Case in Coated Quartz Crystal Microbalance in terms of Ammonia
    Wang, Xiaohua
    Li, Ming
    Chen, Shengyong
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2011, 2011
  • [34] Cellulose acetate nanofibers coated layer-by-layer with polyethylenimine and graphene oxide on a quartz crystal microbalance for use as a highly sensitive ammonia sensor
    Jia, Yongtang
    Yu, Hui
    Zhang, Yumei
    Dong, Fengchun
    Li, Zhe
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2016, 148 : 263 - 269
  • [35] Quartz crystal microbalance VOCs sensor based on dip coated polyaniline emeraldine salt thin films
    Ihdene, Zaher
    Mekki, Ahmed
    Mettai, Boualem
    Mahmoud, Rachid
    Hamada, Boudjema
    Chehimi, Mohamed M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 203 : 647 - 654
  • [36] High-Performance, Room Temperature Hydrogen Sensing With a Cu-BTC/Polyaniline Nanocomposite Film on a Quartz Crystal Microbalance
    Abuzalat, Osama
    Wong, Danny
    Park, Simon S.
    Kim, Seonghwan
    IEEE SENSORS JOURNAL, 2019, 19 (13) : 4789 - 4795
  • [37] Enhanced Dibutyl Phthalate Sensing Performance of a Quartz Crystal Microbalance Coated with Au-Decorated ZnO Porous Microspheres
    Zhang, Kaihuan
    Fan, Guokang
    Hu, Ruifen
    Li, Guang
    SENSORS, 2015, 15 (09) : 21153 - 21168
  • [38] Formaldehyde detection using quartz crystal microbalance (QCM) nanosensor coated by nanoporous MIL-101(Cr) film
    Haghighi, E.
    Zeinali, S.
    MICROPOROUS AND MESOPOROUS MATERIALS, 2020, 300
  • [39] Influence of ZnO morphology on humidity sensing performance based on quartz crystal microbalance
    Xie, Juan
    Wang, Hu
    Duan, Ming
    Tang, Junlei
    JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 2018, 126 (01) : 34 - 38
  • [40] Quartz crystal microbalance odor sensor coated with mixed-thiol-compound sensing film
    Saitoh, A
    Nomura, T
    Munoz, S
    Moriizumi, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1998, 37 (5B): : 2849 - 2852